Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The brachial plexus block is an anesthetic technique often used for surgical procedures of the upper limb. The brachial plexus block through the axilla (BPVA) is one of the techniques most commonly used to obtain regional anesthesia of the upper limbs, being performed by anesthesia of the terminal branches of the brachial plexus, which would be the ulnar, median, radial and musculocutaneous nerves. With the aid of ultrasound , two techniques can be used to perform the BPVA . The first , known as multiple puncture technique , the local anesthetic is deposited around each nerve that want to block . This technique is most commonly used to perform the BPVA . The second technique , known as 2 injections , local anesthetic is deposited below the axillary artery and around the musculocutaneous nerve . This technique has been proposed to try to reduce the execution time of anesthesia . Studies actually show that the technique of 2 injections showed less time to perform the block, with the same success rate. However, the technique of 2 injections showed a longer latency and higher rate of vascular puncture . (14) In order to perform a procedure with shorter execution time , without changing the latency, success rate and ensuring patient safety , the investigators designed this protocol to evaluate three techniques for performing the ultrasound- guided axillary brachial plexus block.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Around Artery | Experimental | Intervention Name: Axillary brachial plexus block Group A: 30 ml of 0.375% bupivacaine will be injected around the artery . If this were a clock, would deposit 7,5 ml of anesthetic in positions 0, 3, 6 and 9 . |
|
| Two injections | Experimental | Group 2: 30 ml of bupivacaine 0.375 % below the artery will be injected in the 6 o'clock position . |
|
| Perineural | Active Comparator | Group Perineural : 10 ml of bupivacaine 0.375 % will be injected around the median, ulnar and radial nerves . |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Axillary brachial plexus block | Procedure |
|
| Measure | Description | Time Frame |
|---|---|---|
| The primary outcome is to compare the efficacy of the three different techniques for ultrasound guided axillary brachial plexus block | The brachial plexus block is performed through the axilla , with the aid of ultrasound and a peripheral nerve stimulator with the patient in the supine position. The needle that will be used is 22G x 50 mm . After disinfection and skin antisepsis with chlorhexidine , tha puncture site will be infiltrated with 1% lidocaine . Furthermore, musculocutaneous nerve will be blockade with 10 ml of 0.375% bupivacaine for all patients. Patients will be divided into three groups : Group A: 30 ml of 0.375% bupivacaine will be injected around the artery . If this were a clock, would deposit 7,5 ml of anesthetic in positions 0, 3, 6 and 9 . Group 2 injections : 30 ml of bupivacaine 0.375 % below the artery will be injected in the 6 o'clock position . Group M : 10 ml of bupivacaine 0.375 % will be injected | The primary outcome will be measured at the same day of the procedure. |
| Measure | Description | Time Frame |
|---|---|---|
| Block Latency | Latency time of the blockade , defined as the time between the end of injection of local anesthetic will be noted. | 30 minutes |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Federal University of São Paulo | São Paulo | São Paulo | 04024002 | Brazil |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 6869868 | Background | Thompson GE, Rorie DK. Functional anatomy of the brachial plexus sheaths. Anesthesiology. 1983 Aug;59(2):117-22. doi: 10.1097/00000542-198308000-00009. | |
| 12170042 | Background | Klaastad O, Smedby O, Thompson GE, Tillung T, Hol PK, Rotnes JS, Brodal P, Breivik H, Hetland KR, Fosse ET. Distribution of local anesthetic in axillary brachial plexus block: a clinical and magnetic resonance imaging study. Anesthesiology. 2002 Jun;96(6):1315-24. doi: 10.1097/00000542-200206000-00009. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 13720553 | Background | DE JONG RH. Axillary block of the brachial plexus. Anesthesiology. 1961 Mar-Apr;22:215-25. doi: 10.1097/00000542-196103000-00010. No abstract available. |
| 6837255 | Background | Vester-Andersen T, Christiansen C, Sorensen M, Kaalund-Jorgensen HO, Saugbjerg P, Schultz-Moller K. Perivascular axillary block II: influence of injected volume of local anaesthetic on neural blockade. Acta Anaesthesiol Scand. 1983 Apr;27(2):95-8. doi: 10.1111/j.1399-6576.1983.tb01913.x. |
| 12567336 | Background | Groban L. Central nervous system and cardiac effects from long-acting amide local anesthetic toxicity in the intact animal model. Reg Anesth Pain Med. 2003 Jan-Feb;28(1):3-11. doi: 10.1053/rapm.2003.50014. |
| 16326341 | Background | Mather LE, Copeland SE, Ladd LA. Acute toxicity of local anesthetics: underlying pharmacokinetic and pharmacodynamic concepts. Reg Anesth Pain Med. 2005 Nov-Dec;30(6):553-66. doi: 10.1016/j.rapm.2005.07.186. |
| 19372356 | Background | Fredrickson MJ, Ball CM, Dalgleish AJ, Stewart AW, Short TG. A prospective randomized comparison of ultrasound and neurostimulation as needle end points for interscalene catheter placement. Anesth Analg. 2009 May;108(5):1695-700. doi: 10.1213/ane.0b013e31819c29b8. |
| 21821517 | Background | Gautier P, Vandepitte C, Ramquet C, DeCoopman M, Xu D, Hadzic A. The minimum effective anesthetic volume of 0.75% ropivacaine in ultrasound-guided interscalene brachial plexus block. Anesth Analg. 2011 Oct;113(4):951-5. doi: 10.1213/ANE.0b013e31822b876f. Epub 2011 Aug 4. |
| 20975468 | Background | Renes SH, van Geffen GJ, Rettig HC, Gielen MJ, Scheffer GJ. Minimum effective volume of local anesthetic for shoulder analgesia by ultrasound-guided block at root C7 with assessment of pulmonary function. Reg Anesth Pain Med. 2010 Nov-Dec;35(6):529-34. doi: 10.1097/AAP.0b013e3181fa1190. |
| 9840855 | Background | Marhofer P, Schrogendorfer K, Wallner T, Koinig H, Mayer N, Kapral S. Ultrasonographic guidance reduces the amount of local anesthetic for 3-in-1 blocks. Reg Anesth Pain Med. 1998 Nov-Dec;23(6):584-8. doi: 10.1016/s1098-7339(98)90086-4. |
| 20705778 | Background | Ponrouch M, Bouic N, Bringuier S, Biboulet P, Choquet O, Kassim M, Bernard N, Capdevila X. Estimation and pharmacodynamic consequences of the minimum effective anesthetic volumes for median and ulnar nerve blocks: a randomized, double-blind, controlled comparison between ultrasound and nerve stimulation guidance. Anesth Analg. 2010 Oct;111(4):1059-64. doi: 10.1213/ANE.0b013e3181eb6372. Epub 2010 Aug 12. |
| 17478453 | Background | Casati A, Baciarello M, Di Cianni S, Danelli G, De Marco G, Leone S, Rossi M, Fanelli G. Effects of ultrasound guidance on the minimum effective anaesthetic volume required to block the femoral nerve. Br J Anaesth. 2007 Jun;98(6):823-7. doi: 10.1093/bja/aem100. Epub 2007 May 3. |
| 18682410 | Background | Riazi S, Carmichael N, Awad I, Holtby RM, McCartney CJ. Effect of local anaesthetic volume (20 vs 5 ml) on the efficacy and respiratory consequences of ultrasound-guided interscalene brachial plexus block. Br J Anaesth. 2008 Oct;101(4):549-56. doi: 10.1093/bja/aen229. Epub 2008 Aug 4. |
| 22660484 | Background | Bernucci F, Gonzalez AP, Finlayson RJ, Tran DQ. A prospective, randomized comparison between perivascular and perineural ultrasound-guided axillary brachial plexus block. Reg Anesth Pain Med. 2012 Sep-Oct;37(5):473-7. doi: 10.1097/AAP.0b013e3182576b6f. |
| 20142336 | Background | Imasogie N, Ganapathy S, Singh S, Armstrong K, Armstrong P. A prospective, randomized, double-blind comparison of ultrasound-guided axillary brachial plexus blocks using 2 versus 4 injections. Anesth Analg. 2010 Apr 1;110(4):1222-6. doi: 10.1213/ANE.0b013e3181cb6791. Epub 2010 Feb 8. |