Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Bedside ultrasonographic assessment of IVC size and IVC collapsibility index can be used to guide the management of patients with acute kidney injury with and without volume overload in the intensive care unit
Consecutive patients presenting to the intensive care unit with a diagnosis of acute renal failure (defined as a 1.5 fold increase in plasma Creatinine level compared to baseline ).
Baseline characteristics will be recorded and followed for each patient, these include:
Focused bedside ultrasound will be performed for each patient as part of their routine care and initial assessment. The IVC size will be measured at the subcostal window, during inspiration and expiration, using the (Sonosite) Cardiac probe P-21 (5-1 MHZ). The measurement is obtained by applying the M-mode, perpendicular to the IVC axis and 2 cm caudal from its junction with the right atrium.
In spontaneously breathing, non-ventilated patients, we will calculate the IVC collapsibility index (IVC-CI) = [IVC max-IVC min]/IVC max.
Whereas in patients who are mechanically ventilated we will calculate their IVC variation index (ΔIVC) = IVC max-IVC min/ IVC mean diameter.
IVC-CI, ΔIVC, IVC size will be used to classify patient as volume responders or non-responder. Prior studies have suggested Intravascular volume depletion is likely present when the, IVC<1 cm , IVC-CI is > 50% in spontaneously breathing patients and volume responsiveness when the ΔIVC is ≥ 12% in mechanically ventilated patient .
The Fractional excretion of sodium as well as the fractional excretion of urea (when diuretics are used) will be calculated to classify the etiology of the renal failure as pre-renal or intrinsic renal failure.
Fluid balance as well as the change in plasma Creatinine level at 48 hours post admission will be recorded.
Two groups of patients will be identified:
Analyses will be done at 24 as well as 48 hours post admission.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Acute renal failure in ICU | Ultrasound for measurement of Inferior Vena Cava size |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ultrasound for measurement of Inferior Vena Cava size. | Other | Focused bedside ultrasound will be performed for each patient as part of their routine care and initial assessment. The IVC size will be measured at the subcostal window, during inspiration and expiration, using the Sonosite cardiac probe P-21 (5-1 MHZ). The measurement is obtained by applying the M-mode, perpendicular to the IVC axis and 2 cm caudal from its junction with the right atrium. |
| Measure | Description | Time Frame |
|---|---|---|
| percentage of patients with improved Creatinine level in group 1 and 2 | percentage of patients with improved Creatinine level in group 1 and 2 | 48 hours |
| Measure | Description | Time Frame |
|---|---|---|
| glomerular filtration rate (GFR), changes in hemodynamic parameters (mean arterial blood pressure, urine output, pressors requirement )and Partial oxygen pressure (PO2) /Fio2 in group 1 and group 2 | glomerular filtration rate (GFR), changes in hemodynamic parameters (mean arterial blood pressure, urine output, pressors requirement) and Partial O2 /Fio2 in group 1 and group 2. Different cut off for IVC size measurement and variations will be used to improve the predictive value of the ultrasound in the management of renal failure in hypervolemic patients. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Consecutive patients presenting to the intensive care unit with a diagnosis of acute renal failure ( Defined as 1.5 fold increase in plasma creatinine level compared to baseline)
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Houssein Youness, MD | University of Oklahoma | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Oklahoma Health Sciences Center | Oklahoma City | Oklahoma | 73104 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29057120 | Derived | Jambeih R, Keddissi JI, Youness HA. IVC Measurements in Critically Ill Patients with Acute Renal Failure. Crit Care Res Pract. 2017;2017:3598392. doi: 10.1155/2017/3598392. Epub 2017 Sep 5. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D058186 | Acute Kidney Injury |
| ID | Term |
|---|---|
| D051437 | Renal Insufficiency |
| D007674 | Kidney Diseases |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D019220 | High-Energy Shock Waves |
| ID | Term |
|---|---|
| D000069453 | Ultrasonic Waves |
| D013016 | Sound |
| D011840 | Radiation, Nonionizing |
| D011827 | Radiation |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| 24 and 48 hours |
| D005261 |
| Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |
| D055585 |
| Physical Phenomena |