To determine if ultrasound measurements can accurately measure the blood pressure of flow across a stent that has been placed in a portal vein to reduce portal vein pressure known as Transjugular Intrahepatic Porto-Systemic shunts or TIPS.
To determine if 3D ultrasound measurements can accurately measure the pressure of blood flow across a stent that has been placed in a portal vein. This has been done in order to reduce portal vein pressure. These shunts are known as Transjugular Intrahepatic Porto-Systemic shunts or TIPS.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Volumetric Flow in TIPS | Other | Subjects who have TIPS (transjugular intrahepatic porto-systemic shunts) have measurements taken to determine if someone has increased blood pressure in the portal vein of the liver (portal hypertension). Subjects who have a TIPS receive clinical ultrasounds every 3 months to determine if the TIPS is working properly. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Volumetric Flow in TIPS | Procedure | Subjects who have a TIPS (transjugular intrahepatic portal-systemic shunt) for portal hypertension will undergo a clinical 3D ultrasound to determine if the TIPS is working properly. Additional ultrasounds will be obtained during the subject's clinically ordered ultrasound(s). These measurements will be taken by using a second ultrasound probe (plastic hand held device that is rubbed along the subject's abdomen). 15 minutes will be added to your clinically ordered exams that are completed 4 times a year. |
| Measure | Description | Time Frame |
|---|---|---|
| Estimate portal blood flow within a transjugular portosystemic shunt | To determine the number of volumes to achieve a specified variance in the measurement and to determine the reproducibility of the volume flow measurements taken at multiple locations within the stent (3 locations with 3 measurements each for a total of 9 acquisitions). The physicians will measure volume flow rate three times at three different locations in the shunt (that being proximal, medial and distal) to determine the reproducibility of the flow estimate. | 4 years |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Paula Novelli, M.D. | University of Michigan Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Michigan Hospital | Ann Arbor | Michigan | 48109 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006975 | Hypertension, Portal |
| D008107 | Liver Diseases |
| ID | Term |
|---|---|
| D004066 | Digestive System Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D019168 | Portasystemic Shunt, Transjugular Intrahepatic |
| ID | Term |
|---|---|
| D011170 | Portasystemic Shunt, Surgical |
| D000714 | Anastomosis, Surgical |
| D013514 | Surgical Procedures, Operative |
| D058017 | Vascular Grafting |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| D014656 | Vascular Surgical Procedures |
| D013504 | Cardiovascular Surgical Procedures |