Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Boehringer Ingelheim | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
We hypothesize that using the ViSiGiâ„¢ Calibration Tube System in patients undergoing LSG will:
Laparoscopic Sleeve Gastrectomy (LSG), is now widely used as a stand-alone procedure for long-term weight loss. With fewer potential morbidities, comparable weight loss and greater ease of conversion to other procedures, many patients now opt for LSG as their bariatric procedure of choice. During surgery gastric decompression and calibration are compulsory for patient safety, gastric anatomic delineation, ease of surgery and optimal weight loss. The removed gastric volume at surgery seems to predict the procedure's success rates2. LSG performed without calibration (tube) could result in inconsistent staple lines, with retained high sleeve volume and consequent failure. Traditionally, although different tubes are used for gastric decompression and calibration, this protocol interrupts operation room (0R) workflow. Accidental stapling of orogastric tubes and bougies do occur in the OR but are seldom reported. The need for this multiple tube system can be obviated with the ViSiGiâ„¢ Calibration Tube System. A single, multipurpose tube that integrates all these various steps could prevent breaks in OR; improve workflow; reduce patient injuries, cross contamination and transmission of infections; and a consistent and reproducible staple line. A similar device has been in use in Europe, Australia and Asia, but the ViSiGiâ„¢ Calibration Tube System is the first of its kind to be approved by the FDA. Currently, there are no data on its clinical safety/efficacy in comparison to standard care of separate orogastric tube and bougie in the United States. Therefore, this exploratory study will investigate the gastric delineation ability, general safety and efficacy of the ViSiGiâ„¢ Calibration Tube System along with the regular bougie in LSG patients over a six- to twelve-month period. Descriptive outcomes will be reported, with no formal sample size calculation in light of the exploratory study design.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| ViSiGi | Experimental | Utilization of ViSiGi calibration tube |
|
| Usual standard of care | Active Comparator | Usual non suction Bougie |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Utilization of ViSiGi calibration tube | Device | Utilization of ViSiGi calibration tube |
|
| Measure | Description | Time Frame |
|---|---|---|
| Efficasy | This exploratory study will investigate the gastric delineation ability, general safety and efficacy of the ViSiGiâ„¢ Calibration Tube System along with the regular bougie in LSG patients over a six- to twelve-month period. Descriptive outcomes will be reported, with no formal sample size calculation in light of the exploratory study design. | 3 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Leonardo Claros, MD | Contact | 4844262600 | Leonardo.Claros@sluhn.org |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Saint Luke's University and Health Network | Allentown | Pennsylvania | 18104 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 26318 | Background | Satiani B, Bonner JT, Stone HH. Factors influencing intraoperative gastric regurgitation: a prospective random study of nasogastric tube drainage. Arch Surg. 1978 Jun;113(6):721-3. doi: 10.1001/archsurg.1978.01370180063008. | |
| 18098398 | Background | Weiner RA, Weiner S, Pomhoff I, Jacobi C, Makarewicz W, Weigand G. Laparoscopic sleeve gastrectomy--influence of sleeve size and resected gastric volume. Obes Surg. 2007 Oct;17(10):1297-305. doi: 10.1007/s11695-007-9232-x. |
| Label | URL |
|---|---|
| ViSiGi web site | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Usual non suction Bougie | Device | Usual non suction Bougie |
|
| 21963196 | Background | Abu-Gazala S, Donchin Y, Keidar A. Nasogastric tube, temperature probe, and bougie stapling during bariatric surgery: a multicenter survey. Surg Obes Relat Dis. 2012 Sep-Oct;8(5):595-600; discussion 600-1. doi: 10.1016/j.soard.2011.08.017. Epub 2011 Aug 31. |
| 21769286 | Background | Pequignot A, Dhahria A, Mensah E, Verhaeghe P, Badaoui R, Sabbagh C, Regimbeau JM. Stapling and Section of the Nasogastric Tube during Sleeve Gastrectomy: How to Prevent and Recover? Case Rep Gastroenterol. 2011;5(2):350-4. doi: 10.1159/000329706. Epub 2011 Jul 6. |
| 16608608 | Background | Sanchez BS, Safadi BY, Kieran JA, Hsu GP, Brodsky JB, Curet MJ, Morton JM. Orogastric tube complications in laparoscopic Roux-en-Y gastric bypass. Obes Surg. 2006 Apr;16(4):443-7. doi: 10.1381/096089206776327350. |
| 6765053 | Background | Vennes JA. Infectious complications of gastrointestinal endoscopy. Dig Dis Sci. 1981 Jul;26(7 Suppl):60S-64S. doi: 10.1007/BF01300809. |
| 23554415 | Background | Kovaleva J, Peters FT, van der Mei HC, Degener JE. Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy. Clin Microbiol Rev. 2013 Apr;26(2):231-54. doi: 10.1128/CMR.00085-12. |
| 10683209 | Background | Schembre DB. Infectious complications associated with gastrointestinal endoscopy. Gastrointest Endosc Clin N Am. 2000 Apr;10(2):215-32. |