Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Purpose of this study is to compare the astigmatic power of the toric IOL obtained from the AcrySof toric calculator, TECNIS toric calculator, and iTrace toric calculator in a group of patients with preoperative with-the-rule (WTR) and against-the-rule (ATR) corneal astigmatism. The study included 100 eyes with cataract and greater than 0.75 diopter of corneal astigmatism, and the subjects were divided into WTR and ATR group. Keratometric value was measured using autokeratometry, IOLMaster partial coherence interferometry (PCI), iTrace incorporating corneal topography and ray-tracing aberrometry. Based on measured values, toric IOL power calculations were performed using AcrySof, TECNIS and iTrace toric calculators.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| a WTR corneal astigmatism group | Corneal astigmatism was defined as WTR when the steep corneal cylinder axis was within 30 degrees of the horizontal axis. | ||
| an ATR corneal astigmatism group | Corneal astigmatism was defined as ATR when the cylinder axis was within 30 degrees of the vertical axis. |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Difference of toric intraocular lens power between three toric calculators | Comparison of the toric intraocular lens power calculated from Acrysof and TECNIS toric calculators using keratometric values measured by autokeratometry or IOLMaster PCI and that from iTrace toric calculator with keratometric value measurement using iTrace ray tracing wavefront aberrometry and iTrace simulated keratometry. | Immediately after measurement |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Subjects who planned to undergo cataract removal by phacoemulsification between January 2013 to April 2013 at the Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea were included in this study.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine | Seoul | 120-752 | South Korea |
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| D001251 | Astigmatism |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
| D012030 | Refractive Errors |
Not provided
Not provided
Not provided
Not provided
Not provided