The goal of this project is to design and validate a force-measuring platform that will measure the magnitude and duration of the load experienced by the lower extremities of individuals with a neuromuscular disability who use a stationary assisted standing device to increase their Bone Mineral Density.
Non-ambulatory children with a neuromuscular disability are at significant risk for poor bone health as reflected by low bone mineral density (BMD) and increased propensity to fracture. In large part, this is due to abnormally low levels of load experienced by the skeleton. A common approach for increasing BMD is to stimulate the musculoskeletal system by increasing the amount and duration of weight-bearing in the lower extremities. For non-ambulatory individuals, this typically takes the form of using an assisted standing device to enable the child to spend time in a standing position so that their lower limbs can experience some degree of body weight. Some of these physical interventions result in varying degrees of improvement in BMD, and some do not. This lack of clarity in outcomes may result from a failure to objectively measure the magnitude and duration of the load experienced by the lower extremities. A lack of change in BMD may be due to the extremities experiencing only a fraction of the body weight due to load-sharing with the assistive device, or to an inadequate duration of standing time. The goal of this project will be to design and validate a force-measuring platform that will measure the magnitude and duration of the load experienced by the lower extremities of individuals with a neuromuscular disability who use a stationary assisted standing device to increase their BMD.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Force-measuring platform | Other | A force-measure platform will be placed under each foot of the subject to record the time course of load borne by each of the lower extremities during weight-bearing training in an assisted standing device. Intervention: Assisted Standing Treatment Program. Assisted standing treatment program will include at least 2 hours a day, 5 days a week (a total of at least 10 hours a week) for a period of ~9 months. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Assisted Standing Treatment Program | Other | Assisted standing treatment program will include at least 2 hours a day, 5 days a week (a total of at least 10 hours a week) for a period of ~9 months. Arm: Force-measuring platform |
| Measure | Description | Time Frame |
|---|---|---|
| Bone Mineral Density | Bone Mineral Density will be measured via dual energy x-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) scans. | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Weight (load)experienced by lower extremities | A platform will measure the magnitude of the load experienced by the lower extremities of individuals with a neuromuscular disability who use a stationary assisted standing device to increase their Bone Mineral Density. | 12 months |
| Duration of standing treatment session(s) (time) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
None
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Walter Truong, MD | Gillette Children's Specialty Healthcare | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Clinical and Translational Science Institute at University of Minnesota | Minneapolis | Minnesota | 55414 | United States | ||
Not provided
| ID | Term |
|---|---|
| D002547 | Cerebral Palsy |
| ID | Term |
|---|---|
| D001925 | Brain Damage, Chronic |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
A platform will measure the duration of the load experienced by the lower extremities of individuals with a neuromuscular disability who use a stationary assisted standing device to increase their Bone Mineral Density. |
| 12 months |
| Caregiver Priorities & Child Health Index of Life with Disabilities (CPCHILD) questionnaire | The CPCHILD© measures caregivers' perspectives on the health status, comfort, well being, functional abilities and ease of caregiving of children with severe developmental disabilities. It was developed to measure the effectiveness of interventions intended to improve or preserve these outcomes for children with severe disabilities, including non-ambulant children with severe cerebral palsy, and traumatic or other acquired brain injuries. This will help determine if care-givers perception of health status changes with changes in standing magnitude and duration. | 12 months |
| Gillette Children's Specialty Healthcare |
| Saint Paul |
| Minnesota |
| 55101 |
| United States |