The study was a randomized double-blind sham-controlled trial for 4 weeks. Patients with schizophrenia were treated with 20-Hz rTMS for 4 weeks to the left dorsolateral prefrontal cortex (added to the ongoing treatment). Negative symptoms were assessed with the Scale for the Assessment of Negative Symptoms (SANS), the Positive and Negative symptom scale (PANSS).The auditory steady state responses (ASSR) were obtained for the assessment of gamma oscillation.And cognitive symptoms were assessed by MATRICS cognitive test battery (MCCB) Chinese version and n-back task.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Active rTMS | Active Comparator | Active treatment will be delivered at an intensity that is 90% of the resting motor threshold (RMT). Stimulation will be delivered at 20 Hz with 100 stimulation trains of 20 stimuli each (i.e., 2000 stimuli) and an inter-train interval of 9 sec. Treatment will be applied in sequential order to the left dorsolateral prefrontal cortex (DLPFC). Intervention: Device: Repetitive Transcranial Magnetic Stimulation |
|
| Sham rTMS | Sham Comparator | Sham rTMS stimulation will be delivered using the same stimulation parameters and at the site of active treatment, but the coil will be reversed. This method produces sound and some somatic sensation (e.g., contraction of scalp muscles) similar to those of active stimulation, but with minimal direct brain effects.Intervention: Device: Repetitive Transcranial Magnetic Stimulation |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Repetitive Transcranial Magnetic Stimulation | Device | The MagPro X100 is connected to a Magnetic Coil which transfers the magnetic stimulation to the tissue. The original coils MC-B65 can be used with the MagPro X100. |
| Measure | Description | Time Frame |
|---|---|---|
| The Change in the Severity of Negative Symptoms | The assessment of negative symptoms were measured with the Positive and Negative Symptom Scale (PANSS) and the Scale for the Assessment of Negative Symptoms (SANS).The SANS contains 30 particular items divided into 5 symptomatological domains: 1) affective flattening and/or blunting, 2) alogia, 3) avolition and/or apathy, 4) anhedonia, and 5) impaired attention. Each item is scored on a scale from 0 (not at all) to 5 (severe) with a total scoring range of 0 to 150. Higher scores indicate more impairment.The PANSS contains 30 particular items divided into 3 subscores: 1)positive, 2) negative, and 3) general subscore. Each item is scored on a scale from 1 (absent) to 7 (extreme) with a total scoring range of 30 to 210. Higher scores indicate more impairment. The primary outcomes were the changes in the severity of negative symptoms as measured with SANS total score and PANSS negative subscore after 4 weeks of intervention. | Baseline, after 4 weeks of treatment |
| Measure | Description | Time Frame |
|---|---|---|
| MATRICS Consensus Cognitive Battery (MCCB) in Chinese Version | MCCB in Chinese Version includes 9 tasks across 7 domains, and a composite score, including Processing Speed (Brief Assessment of Cognition in Schizophrenia Symbol Coding, Animal Fluency, Trails A), Attention (Continuous Performance Test), Working Memory (WMS-III Spatial Span), Verbal Learning (Hopkins Verbal Learning Test - Revised), Visual Learning (Brief Visuospatial Memory Test - Revised), Problem Solving (Neuropsychological Assessment Battery), and Social Cognition (Mayer-Salovey- Caruso Emotional Intelligence Test).The results are reported as T scores with a mean of 50 and an SD of 10. |
| Measure | Description | Time Frame |
|---|---|---|
| Event-related Spectral Perturbation (ERSP) | Alterations in gamma-band ASSR have been thought to be the most robust finding of abnormal neural oscillations in patients with schizophrenia. EEG data were acquired using a 64-electrode cap and alternating current BrainAmp amplifiers (Brain Products GmbH, Germany). We used EEGLAB to perform time-frequency analysis with a short-term Fourier transformation, and then calculated ERSP. |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Dengtang Liu, MD | Chief Psychiatrist and Professor | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine | Shanghai | Shanghai Municipality | 200030 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31190822 | Derived | Zhuo K, Tang Y, Song Z, Wang Y, Wang J, Qian Z, Li H, Xiang Q, Chen T, Yang Z, Xu Y, Fan X, Wang J, Liu D. Repetitive transcranial magnetic stimulation as an adjunctive treatment for negative symptoms and cognitive impairment in patients with schizophrenia: a randomized, double-blind, sham-controlled trial. Neuropsychiatr Dis Treat. 2019 May 8;15:1141-1150. doi: 10.2147/NDT.S196086. eCollection 2019. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Active rTMS | Active treatment will be delivered at an intensity that is 80% of the resting motor threshold (RMT). Stimulation will be delivered at 20 Hz with 100 stimulation trains of 20 stimuli each (i.e., 2000 stimuli) and an inter-train interval of 9 sec. Treatment will be applied in sequential order to the left dorsolateral prefrontal cortex (DLPFC). Intervention: Device: Repetitive Transcranial Magnetic Stimulation Repetitive Transcranial Magnetic Stimulation: The MagPro X100 is connected to a Magnetic Coil which transfers the magnetic stimulation to the tissue. The original coils MC-B65 can be used with the MagPro X100. |
| FG001 | Sham rTMS | Sham rTMS stimulation will be delivered using the same stimulation parameters and at the site of active treatment, but the coil will be reversed. This method produces sound and some somatic sensation (e.g., contraction of scalp muscles) similar to those of active stimulation, but with minimal direct brain effects. Repetitive Transcranial Magnetic Stimulation: The MagPro X100 is connected to a Magnetic Coil which transfers the magnetic stimulation to the tissue. The original coils MC-B65 can be used with the MagPro X100. |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Active rTMS | Active treatment will be delivered at an intensity that is 80% of the resting motor threshold (RMT). Stimulation will be delivered at 20 Hz with 100 stimulation trains of 20 stimuli each (i.e., 2000 stimuli) and an inter-train interval of 9 sec. Treatment will be applied in sequential order to the left dorsolateral prefrontal cortex (DLPFC). Intervention: Device: Repetitive Transcranial Magnetic Stimulation Repetitive Transcranial Magnetic Stimulation: The MagPro X100 is connected to a Magnetic Coil which transfers the magnetic stimulation to the tissue. The original coils MC-B65 can be used with the MagPro X100. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | The Change in the Severity of Negative Symptoms | The assessment of negative symptoms were measured with the Positive and Negative Symptom Scale (PANSS) and the Scale for the Assessment of Negative Symptoms (SANS).The SANS contains 30 particular items divided into 5 symptomatological domains: 1) affective flattening and/or blunting, 2) alogia, 3) avolition and/or apathy, 4) anhedonia, and 5) impaired attention. Each item is scored on a scale from 0 (not at all) to 5 (severe) with a total scoring range of 0 to 150. Higher scores indicate more impairment.The PANSS contains 30 particular items divided into 3 subscores: 1)positive, 2) negative, and 3) general subscore. Each item is scored on a scale from 1 (absent) to 7 (extreme) with a total scoring range of 30 to 210. Higher scores indicate more impairment. The primary outcomes were the changes in the severity of negative symptoms as measured with SANS total score and PANSS negative subscore after 4 weeks of intervention. | Ten patients dropped out due to different reasons (three patients refused to participated, three did not complianted and the other four were discharged before completion of study) | Posted | Mean | Full Range | units on a scale | Baseline, after 4 weeks of treatment |
6 months
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Sham rTMS | 3 subjects reported a transient headache in the initial period, After giving comfort the symptoms were significantly reduced. No other adverse events were observed. |
Not provided
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| headache | General disorders | Systematic Assessment |
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| ShanghaiMHC | Dr.LIU | 862134773775 | erliu110@126.com |
Not provided
| ID | Term |
|---|---|
| D012559 | Schizophrenia |
| ID | Term |
|---|---|
| D019967 | Schizophrenia Spectrum and Other Psychotic Disorders |
| D001523 | Mental Disorders |
Not provided
Not provided
| ID | Term |
|---|---|
| D050781 | Transcranial Magnetic Stimulation |
| ID | Term |
|---|---|
| D055909 | Magnetic Field Therapy |
| D013812 | Therapeutics |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Baseline and 4 weeks |
| 4 weeks |
| BG001 | Sham rTMS | Sham rTMS stimulation will be delivered using the same stimulation parameters and at the site of active treatment, but the coil will be reversed. This method produces sound and some somatic sensation (e.g., contraction of scalp muscles) similar to those of active stimulation, but with minimal direct brain effects. Repetitive Transcranial Magnetic Stimulation: The MagPro X100 is connected to a Magnetic Coil which transfers the magnetic stimulation to the tissue. The original coils MC-B65 can be used with the MagPro X100. |
| BG002 | Total | Total of all reporting groups |
| Participants |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| ID | Title | Description |
|---|---|---|
| OG000 | Active rTMS | Active treatment will be delivered at an intensity that is 80% of the resting motor threshold (RMT). Stimulation will be delivered at 20 Hz with 100 stimulation trains of 20 stimuli each (i.e., 2000 stimuli) and an inter-train interval of 9 sec. Treatment will be applied in sequential order to the left dorsolateral prefrontal cortex (DLPFC). Intervention: Device: Repetitive Transcranial Magnetic Stimulation Repetitive Transcranial Magnetic Stimulation: The MagPro X100 is connected to a Magnetic Coil which transfers the magnetic stimulation to the tissue. The original coils MC-B65 can be used with the MagPro X100. |
| OG001 | Sham rTMS | Sham rTMS stimulation will be delivered using the same stimulation parameters and at the site of active treatment, but the coil will be reversed. This method produces sound and some somatic sensation (e.g., contraction of scalp muscles) similar to those of active stimulation, but with minimal direct brain effects. Repetitive Transcranial Magnetic Stimulation: The MagPro X100 is connected to a Magnetic Coil which transfers the magnetic stimulation to the tissue. The original coils MC-B65 can be used with the MagPro X100. |
|
|
| Secondary | MATRICS Consensus Cognitive Battery (MCCB) in Chinese Version | MCCB in Chinese Version includes 9 tasks across 7 domains, and a composite score, including Processing Speed (Brief Assessment of Cognition in Schizophrenia Symbol Coding, Animal Fluency, Trails A), Attention (Continuous Performance Test), Working Memory (WMS-III Spatial Span), Verbal Learning (Hopkins Verbal Learning Test - Revised), Visual Learning (Brief Visuospatial Memory Test - Revised), Problem Solving (Neuropsychological Assessment Battery), and Social Cognition (Mayer-Salovey- Caruso Emotional Intelligence Test).The results are reported as T scores with a mean of 50 and an SD of 10. | Ten patients dropped out due to different reasons (three patients refused to participated, three did not complianted and the other four were discharged before completion of study) | Posted | Mean | Standard Deviation | MCCB(T score) | Baseline and 4 weeks |
|
|
|
| Other Pre-specified | Event-related Spectral Perturbation (ERSP) | Alterations in gamma-band ASSR have been thought to be the most robust finding of abnormal neural oscillations in patients with schizophrenia. EEG data were acquired using a 64-electrode cap and alternating current BrainAmp amplifiers (Brain Products GmbH, Germany). We used EEGLAB to perform time-frequency analysis with a short-term Fourier transformation, and then calculated ERSP. | patients discontinualed treatment | Posted | Mean | Full Range | dB | 4 weeks |
|
|
|
| 0 |
| 35 |
| 3 |
| 35 |
| EG001 | Active rTMS | 4 subjects reported a transient headache and 1 subjects reported dizziness in the initial period.After giving comfort and reducing initial intensity of stimulation, the symptoms were significantly reduced. No other adverse events were observed. | 0 | 35 | 5 | 35 |
| dizzsiness | General disorders | Systematic Assessment |
|