Deep Vein Thrombosis (DVT) is a life threatening condition and a serious concern among hospitalized patients, with death occurring in approximately 6% of cases. It involves the formation of a clot where stagnant blood flow occurs, predominantly in the deep veins of the legs. Three mechanisms underlie DVT, venous stasis (slowing or stopping of the blood), hypercoagulability (increased clotting) and damage to blood vessel endothelium (damage to blood vessel wall), collectively known as Virchow's triad.
Intermittent pneumatic compression (IPC) and neuromuscular electrical stimulation (NMES) have been shown to improve lower limb blood flow. However, few studies have directly compared the two methods and those that have, have used dated NMES techniques.
The objective of this study is to compare the two methods in terms of blood flow, in both a young and an older population.
Deep Vein Thrombosis (DVT) is a life threatening condition and a serious concern among hospitalized patients, with death occurring in approximately 6% of cases. It involves the formation of a clot where stagnant blood flow occurs, predominantly in the deep veins of the legs. Three mechanisms underlie DVT, venous stasis (slowing or stopping of the blood), hypercoagulability (increased clotting) and damage to blood vessel endothelium (damage to blood vessel wall), collectively known as Virchow's triad.
Intermittent Pneumatic Compression (IPC) involves the use of an inflatable cuff placed around the limb. This cuff inflates and deflates intermittently in order to squeeze blood from the underlying veins. Neuromuscular Electrical Stimulation (NMES) leads to a contraction of muscles by delivering a series of controlled electrical pulses via skin surface electrodes placed over the motor points of the targeted muscle.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| DVT Prophylaxis | Experimental | Neuromuscular electrical stimulation is to be applied using a custom-built, two-channel stimulator (Bioelectronics Research Cluster, National University of Ireland, Galway) with a frequency of 36 Hz, a balanced biphasic waveform with a pulse width of 350μs, a ramp up time of 500ms, a contraction time of 1s and a ramp down time of 500ms. Stimulation is to be applied every 20 seconds over a period of 5 minutes. Intermittent pneumatic compression is to be applied using the Novamedix A-V Impulse System Model 6000 (Novamedix distribution Limited, England), programmed to deliver compression every 20 seconds at a pressure of 130 mmHg for a 3 second duration over a period of 5 minutes. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Neuromuscular electrical stimulator | Device |
| ||
| AV Impulse System Model 6000 |
| Measure | Description | Time Frame |
|---|---|---|
| Blood flow measurements from the lower limb | Doppler measurements will be taken for each of the interventions.The measurement site of interest is the popliteal vein, located at the back of the knee. Peak venous velocity, time averaged mean velocity, vein cross-sectional area and volume flow will be recorded. 3 measurements of each will be taken per intervention. No measurements will be taken within the first minute of the intervention. | Two hours (plus or minus half an hour) |
| Measure | Description | Time Frame |
|---|---|---|
| Blood pressure | Blood pressure will be measured throughout the study using an OMRON RX3 Plus digital automatic blood pressure monitor. | Two hours (plus or minus half an hour) |
| Heart rate | Heart rate will be measured throughout the study using an OMRON RX3 Plus digital automatic blood pressure monitor. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gearoid OLaighin, PhD | National University of Ireland, Galway | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| National University of Ireland, Galway | Galway | Ireland |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
|
|
| Two hours (plus or minus half an hour) |
| ID | Term |
|---|---|
| D020246 | Venous Thrombosis |
| ID | Term |
|---|---|
| D013927 | Thrombosis |
| D016769 | Embolism and Thrombosis |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D048228 | Intermittent Pneumatic Compression Devices |
| ID | Term |
|---|---|
| D004864 | Equipment and Supplies |
Not provided
Not provided