One lung ventilation (OLV) is accomplished with a double lumen tube (DLT) or a bronchial blocker (BB). In this study, the investigators compared the effectiveness of lung collapse using DLT, BB with spontaneous collapse, and BB with disconnection technique.
In selecting this maneuver of OLV, lung collapse is a major concern because it permits adequate surgical exposure. Although once lung deflation was achieved, the overall clinical performance appears to be similar, BB takes longer to deflate the operative lung and there is some conflict reports as to BB provides a similar degree of lung deflation compared to that of DLT.
The aim of this study was to compare the efficacy of BB and DLT for achieving lung collapse, and to evaluate the efficacy of disconnection technique with monitoring the carbon dioxide trace on a capnograph in BB. The investigators further evaluated the disconnection time, which is the time to loss of carbon dioxide trace on the capnograph, needed to facilitate lung collapse.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| DLT with conventional technique | Experimental | The double lumen tube is introduced into the glottis under direct laryngoscopy. After the bronchial cuff had passes the vocal cords, the tube is rotated counterclockwise 90° and advanced until a slight resistance was encountered. One lung ventilation is initiated after the lumen of operative lung is clamped and opened. |
|
| BB with conventional technique | Active Comparator | The brochial blocker (BB) is introduced through the endotracheal tube to the desired bronchus under fiberoptic bronchoscopy (FOB) vision by turning the device's steering wheel. The BB cuff is inflated with air under FOB vision with the volume necessary to seal the bronchus and initiate one lung ventilation. And then, dependent lung is ventilated. |
|
| Disconnection technique | Active Comparator | Disconnection technique; 1) before initiating OLV, we turned-off the ventilator and fully opened the adjustable pressure limiting valve allowing both lungs to collapse, and 2) after loss of the carbon dioxide trace on the capnograph, 3) inflated the BB cuff with air, and 4) turned-on the ventilator allowing only dependent-lung reventilation. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| DLT with conventional technique | Procedure | The double lumen tube is introduced into the glottis under direct laryngoscopy. After the bronchial cuff had passes the vocal cords, the tube is rotated counterclockwise 90° and advanced until a slight resistance was encountered. |
| Measure | Description | Time Frame |
|---|---|---|
| Effectiveness of three lung isolation methods | The degree of lung collapse after 5 min from the start of OLV. The degree of lung collapse was assessed using a lung collapse score (0 = no collapse, to 10 = complete collapse) by one thoracic surgeon. The surgeon who assessed the lung collapse was absent from the operating room during DLT or BB placement and was blinded to the airway device. | Five min from the start of one lung ventilation |
| Effectiveness of three lung isolation methods | The degree of lung collapse after 5 min from the start of OLV. The degree of lung collapse was assessed using a lung collapse score (0 = no collapse, to 10 = complete collapse) by one thoracic surgeon. The surgeon who assessed the lung collapse was absent from the operating room during DLT or BB placement and was blinded to the airway device. | Ten min from the start of one lung ventilation |
| Measure | Description | Time Frame |
|---|---|---|
| The disconnection time | Before initiating OLV in group 3, we turned-off the ventilator and fully opened the adjustable pressure limiting valve allowing both lungs to collapse. And then, the time which capnograph lose the carbon dioxide curve is considered the disconnection time required for both lungs to collapse before initiating one lung ventilation. | The time to loss the carbon dioxide trace on the capnograph (30 seconds) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Sung Yong Park, MD | Ajou University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ajou University Hospital | Suwon | Gyung Gi | 443-721 | South Korea |
Not provided
| ID | Term |
|---|---|
| D011030 | Pneumothorax |
| ID | Term |
|---|---|
| D010995 | Pleural Diseases |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| BB with conventional technique | Procedure | The brochial blocker (BB) is introduced through the endotracheal tube to the desired bronchus under FOB vision by turning the device's steering wheel. The BB cuff is inflated with air under FOB vision with the volume necessary to seal the bronchus and initiate one lung ventilation. |
|
| Disconnection technique | Procedure | Disconnection technique 1) deflate of the blocker cuff, 2) turn-off the ventilator and opened the APL valve allowing both lungs to collapse, 3) after loss of carbon dioxide trace in the capnograph, reinflate blocker cuff with the same volume of air as during the initial insertion, 4) reconnect the tube to the ventilator allowing only dependent-lung reventilation with a 5 cmH2O positive end-expiratory pressure preceded by a single recruitment maneuver performed by elevating the airway pressure to 40 cmH2O for 7 seconds. |
|