The purpose of this study is to determine whether the Erchonia® ML Scanner (MLS) is effective in the treatment of acute minor episodic chronic low back pain of musculoskeletal origin.
Back pain is a common musculoskeletal disorder affecting 80% of people at some point in their lives. It is the second most common neurological ailment in the United States, second only to headache, and it is the most common cause of job-related disability and a leading contributor to missed work. Around $50 billion is spent in the U.S. each year to treat low back pain. Men and women are equally affected, with the most common age affected being between 30 and 50 years.
Most low back pain stems from benign musculoskeletal problems, referred to as non-specific low back pain, which is the etiology being evaluated in this study. It is caused by lumbar sprain or strain a stretch injury to the ligaments, tendons, and/or muscles of the low back.
Current mainstream treatment approaches for low back pain due to lumbar sprain strain focus on reducing pain and inflammation, including rest; oral and topical over-the-counter and prescription medications; local heat applications; massage and exercise. Alternative treatment options include acupuncture; chiropractic manipulation; biofeedback; traction; transcutaneous electrical nerve stimulation (TENS); and ultrasound. Surgical procedures are also a treatment option for low back pain, and although the outcomes are often poor and do not last, back surgery remains the 3rd most common form of surgery in the United States, with about 300,000 back surgeries performed annually.
Low Level Laser Therapy (LLLT) communicates information to the receptors on the membrane of the cell and mitochondrion (the enzymatic engine of the cell). This energetic information reaches the cell's DNA, which directly controls cell function. When the cells receive better information, they work better, as do the tissues they comprise, like bones, cartilage, tendons, ligaments, etc. In this way, LLLT promotes the healing and regeneration of damaged tissues, having both local effects on tissue function and also systemic effects carried throughout the body by the blood and acupuncture meridians. The key basic physiological effects of low level laser light include increased cell membrane polarization and permeability; Adenosine-5-triphosphate (ATP) production and respiratory chain activity; enzyme activity; collagen and epithelial production; capillary formation; macrophage (immune) activity; analgesic effects due to elevated endorphin production, electrolytic nerve blockage, and improved blood and lymph flow; anti-inflammatory effect due to improved circulation and accelerated tissue regeneration; and increased production of antioxidants. Of additional benefit is that light energy from low level lasers will only be absorbed by cells and tissues that are not functioning normally and has no effect on healthy cells.
Therefore, low level laser therapy has the potential benefit of providing an effective means of reducing low back pain that is simple, quick, non-invasive and side-effect free.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Erchonia MLS | Active Comparator | The Erchonia® MLS contains 10 independent diodes, each emitting 17 milliwatts (mW), 635 nanometers (nm) of red laser light. |
|
| Placebo Laser | Placebo Comparator | The Placebo Laser has the same appearance as the Erchonia MLS but does not emit any therapeutic light. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Erchonia MLS | Device | The Erchonia® MLS contains 10 independent diodes, each emitting 17 milliwatts (mW), 635 nanometers (nm) of red laser light. The Erchonia MLS is applied to the lower back and hips area for 15 minutes per treatment administration, 6 times across 3 weeks, 2 times per week. |
| Measure | Description | Time Frame |
|---|---|---|
| Difference in the Proportion of Primary Outcome Successes Between Treatment Groups | Primary outcome success for an individual subject was defined as a 30% or greater change (decrease) in VAS pain score at 4 months post-procedure relative to baseline. The VAS is a straight line scale that is marked on one end with a '0' for 'no pain' and at the other end with '100' for 'worse pain imaginable.' A higher score indicates a greater level of pain, and a lower score indicates a lower level of pain. A negative (-) percent change in VAS rating indicates a decrease in pain level and is positive for individual subject success. A positive (+) percent change indicates an increase in pain level and is negative for individual subject success. Overall study success was defined as a 35% or greater difference in the proportion of individual primary outcome successes in each treatment group, in favor of the active treatment group. | 4 Months |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Low Back Pain Visual Analog Scale (VAS) Score | The VAS is a straight line scale that is marked on one end with a '0' for 'no pain' and at the other end with '100' for 'worse pain imaginable.' A higher score on the VAS indicates a greater level of pain, and a lower score indicates a lower level of pain.A decrease in the VAS pain rating indicates a reduction in low back pain and is positive for study success. An increase in the VAS pain rating indicates a worsening of low back pain and is negative for study success. The mean change in low back pain score recorded on the Visual Analog Scale (VAS) from baseline to 4 months post-procedure was calculated for each treatment group. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Trevor Berry, DC | Principal Investigator | |
| Mark B Burdorf, DC, DACNB | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| South Mountain Chiropractic Center | Chandler | Arizona | 86226 | United States | ||
| Mark B. Burdorf DC |
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Erchonia MLS | The Erchonia MLS contains 10 independent diodes, each emitting 17 milliwatts (mW), 635 nanometers (nm) of red laser light. It is applied to the lower back and hips area for 30 minutes per treatment administration, 6 times across 3 weeks, 2 times per week. |
| FG001 | Placebo Laser | The Placebo Laser has the same appearance as the Erchonia MLS but does not emit any therapeutic light. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Erchonia MLS | The Erchonia MLS contains 10 independent diodes, each emitting 17 milliwatts (mW), 635 nanometers (nm) of red laser light. The Erchonia MLS is applied to the lower back and hips area for 15 minutes per treatment administration, 6 times across 3 weeks, 2 times per week. |
| BG001 |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Difference in the Proportion of Primary Outcome Successes Between Treatment Groups | Primary outcome success for an individual subject was defined as a 30% or greater change (decrease) in VAS pain score at 4 months post-procedure relative to baseline. The VAS is a straight line scale that is marked on one end with a '0' for 'no pain' and at the other end with '100' for 'worse pain imaginable.' A higher score indicates a greater level of pain, and a lower score indicates a lower level of pain. A negative (-) percent change in VAS rating indicates a decrease in pain level and is positive for individual subject success. A positive (+) percent change indicates an increase in pain level and is negative for individual subject success. Overall study success was defined as a 35% or greater difference in the proportion of individual primary outcome successes in each treatment group, in favor of the active treatment group. | Posted | Number | participants | 4 Months |
|
4 months
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Erchonia MLS | The Erchonia MLS contains 10 independent diodes, each emitting 17 milliwatts (mW), 635 nanometers (nm) of red laser light applied to the lower back and hips area for 30 minutes per treatment administration, 6 times across 3 weeks, 2 times per week. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Clinical Consultant | Regulatory Insight, Inc. | 615-712-9743 | elvira@reginsight.com |
Not provided
| ID | Term |
|---|---|
| D017116 | Low Back Pain |
| ID | Term |
|---|---|
| D001416 | Back Pain |
| D010146 | Pain |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Placebo Laser | Device | The Placebo Laser has the same appearance and administration application as the Erchonia MLS but does not emit any therapeutic light. |
|
| Baseline and 4 Months |
| Satisfaction With Study Outcome | At study endpoint, the subject was asked to rate how satisfied he or she was with any overall change in low back pain attained following the procedure administration phase with the Erchonia MLS Laser, using the following five-point scale: Very Satisfied Somewhat Satisfied Neither Satisfied nor Dissatisfied Not Very Satisfied Not at All Satisfied Results are reported as the number of subjects who reported being 'Very Satisfied' or 'Somewhat Satisfied' with the study outcome. | 4 Months |
| Scottsdale |
| Arizona |
| 85260 |
| United States |
| Placebo Laser |
The Placebo Laser has the same appearance and treatment application as the Erchonia MLS but does not emit any therapeutic light. |
| BG002 | Total | Total of all reporting groups |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| Duration of Low Back Pain | Duration of low back pain was recorded as the number of months the subject reporting experiencing ongoing low back pain. | Mean | Standard Deviation | months |
|
| Visual Analog Scale (VAS) Degree of Low Back Pain Rating | The Visual Analog Pain Scale (VAS) is one of the three most commonly used scales for assessing chronic pain. The VAS scale ranges from 0 to 100 mm, with 0 indicating no pain and 100 indicating the worst pain imaginable. The subject marks on the line the spot for the pain intensity, which is then measured using a ruler. | Mean | Standard Deviation | units on a scale |
|
The Erchonia MLS contains 10 independent diodes, each emitting 17 milliwatts (mW), 635 nanometers (nm) of red laser light, applied to the lower back and hips area for 15 minutes per treatment administration, 6 times across 3 weeks, 2 times per week.
| OG001 | Placebo Laser | The Placebo Laser has the same appearance and administration application as the active Erchonia MLS but does not emit any therapeutic light. |
|
|
|
| Secondary | Change in Low Back Pain Visual Analog Scale (VAS) Score | The VAS is a straight line scale that is marked on one end with a '0' for 'no pain' and at the other end with '100' for 'worse pain imaginable.' A higher score on the VAS indicates a greater level of pain, and a lower score indicates a lower level of pain.A decrease in the VAS pain rating indicates a reduction in low back pain and is positive for study success. An increase in the VAS pain rating indicates a worsening of low back pain and is negative for study success. The mean change in low back pain score recorded on the Visual Analog Scale (VAS) from baseline to 4 months post-procedure was calculated for each treatment group. | Posted | Mean | Standard Deviation | units on a scale | Baseline and 4 Months |
|
|
|
|
| Secondary | Satisfaction With Study Outcome | At study endpoint, the subject was asked to rate how satisfied he or she was with any overall change in low back pain attained following the procedure administration phase with the Erchonia MLS Laser, using the following five-point scale: Very Satisfied Somewhat Satisfied Neither Satisfied nor Dissatisfied Not Very Satisfied Not at All Satisfied Results are reported as the number of subjects who reported being 'Very Satisfied' or 'Somewhat Satisfied' with the study outcome. | Posted | Number | participants | 4 Months |
|
|
|
| 0 |
| 31 |
| 0 |
| 31 |
| EG001 | Placebo Laser | The Placebo Laser has the same appearance and administration application as the Erchonia MLS but does not emit any therapeutic light. | 0 | 31 | 0 | 31 |
Not provided
Not provided
| D013568 |
| Pathological Conditions, Signs and Symptoms |