The functionality and reproducibility of pulse wave analysis is investigated in 20 type 2 diabetic patients who had two 24 hour measurements performed within one week with the Arteriograph24 equipment.
Arteriograph24 is a new monitor for measuring ambulatory blood pressure and additional performing brachial cuff based on analysis of a suprasystolic pulse wave.
The study aim to test the feasibility of ambulatory pulse wave analysis every twenty minute (the fraction of missed measurements)and the reprodicility of pulse wave velocity and central augmentation index in type 2 diabetic patients. In addition we will explore the relation between diurnal variation of brachial blood pressure, central blood pressure and pulse wave velocity.
20 type 2 diabetic patients will have 24h ambulatory blood pressure performed twice with an interval of one week.
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Fraction of missed pulse wave analysis | Measurements of ambulatory blood pressure and pulse wave analysis is performed every twenty minute. The fraction of missed measurements of pulse wave analysis during day time and night time analysis is the final outcome | Meaured two times with an interval of one week |
| Measure | Description | Time Frame |
|---|---|---|
| Reproducibility of pulse wave analysis parameters | Reproducibility of pulse wave velocity, Central systolic blood pressure and central augmentation index for 24 hour, day and night | Measured two times with an interval of one week |
| Measure | Description | Time Frame |
|---|---|---|
| Diurnal variation of brachial blood pressure, central blood pressure and pulse wave velocity | brachial blood pressure, central blood pressure and pulse wava velocity is measured evrey twenty minutes and averaged for day time and night time. the relative reduction at nioght for the parameters are calculated | Measured two times with an interval of one week |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Type 2 diabetes patients recruited from out patient clinic
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Klavs W Hansen, MD, dr.med. | Medical department, Diagnostic Center, Regional Hospital Silkeborg, Denmark | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical department, Diagnostic Center, Regional Hospital Silkeborg | Silkeborg | Silkeborg | 8600 | Denmark |
Not provided
| ID | Term |
|---|---|
| D003924 | Diabetes Mellitus, Type 2 |
| D003920 | Diabetes Mellitus |
| ID | Term |
|---|---|
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
| D004700 | Endocrine System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided