To assess the feasibility of a new brain tissue probe for multi-parameter neuromonitoring (NeMo Probe) and the accuracy of measurement values.
To demonstrate the ability of the NeMo probe to detect changes in cerebral hemodynamics and oxygenation during cerebrovascular events monitored with established methods including brain tissue oxygenation tension and microdialysis
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| NeMoProbe | Other | The NeMo System is used for intracranial pressure (ICP) and brain temperature monitoring, as well as the determination of the brain tissue oxygenation saturation (SbtO2) and cerebral blood flow. The sensors for NIRS are implemented into a conventional brain tissue probe for ICP monitoring (NeMo Probe). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| NeMo Probe | Device | A new minimal-invasive brain tissue probe applying near infrared spectroscopy |
|
| Measure | Description | Time Frame |
|---|---|---|
| To assess the feasibility of the neuromonitoring system and accuracy of the measurement values | Feasibility: User acceptance rate in comparison to conventional probes for ICP-monitoring. The following parameters will be analysed:
Safety endpoints: -Adverse events profile (including adverse device effects): Incidence of complications (infections, brain tissue damage, hemorrhage) in comparison to historical series (conventional probes for ICP-monitoring): | Day 90 after Removal of Medical Device |
| Measure | Description | Time Frame |
|---|---|---|
| To demonstrate the ability of the neuromonitoring system to detect cerebrovascular events in patients with subarachnoid hemorrhage | Results concerning the response to cortical spreading depolarization (CSD) monitored with electrocorticography (ECoG): Increase of brain tissue oxygenation (SbtO2), total hemoglobin (dHbtotal, aHbtotal), CBV, CBV Hb and CBF >20% Decrease of SbtO2, dHbtotal, aHbtotal, CBV, CBV Hb and CBF >20% Changes of SbtO2, dHbtotal, aHbtotal, CBV, CBV Hb and CBF <20% Results concerning the sensitivity and specificity to detect delayed cerebral ischemia (DCI) monitored with ptiO2 and MD: Correlation of CBF values <15 ml/100g/min with defined criteria for DCI (ptiO2 <15 mmHg, Gluc brain<0.7 mmol/l, Lactate-Pyruvate-Ratio >40), number of false negative and false positive events, Receiver Operating Characteristic (ROC) curve. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Martin Seule, MD | Department of Neurosurgery, University Hospital Heidelberg | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Neurosurgery, University Hospital Heidelberg | Heidelberg | 69221 | Germany |
Not provided
| ID | Term |
|---|---|
| D013345 | Subarachnoid Hemorrhage |
| ID | Term |
|---|---|
| D020300 | Intracranial Hemorrhages |
| D002561 | Cerebrovascular Disorders |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Day 90 after Removal of Medical Device |
| D009422 | Nervous System Diseases |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D006470 | Hemorrhage |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |