The investigators aimed to compare two approaches thoracoscopic epicardial ablation and endocardial catheter ablation after failed initial catheter ablation in patients with paroxysmal atrial fibrillation.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Thoracoscopic epicardial ablation | Active Comparator | Patients were treated with video-assisted thoracoscopy under general anesthesia. PVI was performed from the epicardial side with a bipolar RF ablation clamp (AtriCure). At least 2 overlapping applications around each of the ipsilateral veins were made, and isolation was confirmed by the absence of PV potentials and exit block during pacing. An additional application was made in the interatrial Waterston groove in the right side to isolate the ganglionic plexi from the atria. On the left side, the ligament of Marshal was cut, but no additional ablation of ganglionic plexi was pursued. The RevealXT (implantable loop recorder) was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
|
| Endocardial catheter ablation | Active Comparator | Externally-irrigated tip (5-mm tip, Celsius Thermo-Cool, Biosense Webster, Diamond Bar, CA, USA). Temperature-controlled RF delivery was performed with a maximum power output of 50 W and temperature limit of 50 C. The catheter was irrigated using 0.9% saline infusion at a flow rate of 20-40 mL/min during RF delivery and 2 mL/min between applications using a commercially available pump (Cool Flow, Biosense Webster). The RevealXT (implantable loop recorder) was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Thoracoscopic epicardial ablation | Procedure |
| ||
| Endocardial catheter ablation |
| Measure | Description | Time Frame |
|---|---|---|
| freedom from any atrial arrhythmia | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| rate of significant adverse events (SAEs) | 12 months | |
| atrial fibrillation burden by ILR | 12 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Evgeny Pokushalov, MD, PhD | State Research Institute of Circulation Pathology | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| State Research Institute of Circulation Pathology | Novosibirsk | 630055 | Russia |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 24016147 | Derived | Pokushalov E, Romanov A, Elesin D, Bogachev-Prokophiev A, Losik D, Bairamova S, Karaskov A, Steinberg JS. Catheter versus surgical ablation of atrial fibrillation after a failed initial pulmonary vein isolation procedure: a randomized controlled trial. J Cardiovasc Electrophysiol. 2013 Dec;24(12):1338-43. doi: 10.1111/jce.12245. Epub 2013 Sep 9. |
| Label | URL |
|---|---|
| State Research Institute of Circulation Pathology Official Site | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Procedure |
|
| Implantable loop recorder | Device |
|
| ID | Term |
|---|---|
| D001281 | Atrial Fibrillation |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided