Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Energy devices are used routinely during thyroid surgery to aid surgical dissection and to stop bleeding. The newer generation energy devices have several advantages over older machines. The two most commonly used newer generation energy devices are the Harmonic scalpel and the Small Jaw bipolar device. Currently there has been no randomized controlled trial that compares both devices side to side. We aim to compare the effectiveness of these two newer generation energy devices in thyroid surgery.
Energy devices are used routinely during thyroid surgery to aid surgical dissection and haemostasis. The newer generation energy devices have several advantages over older machines. First, the newer devices deliver more focussed thermal application and thus are less likely to cause collateral injury to surrounding healthy tissue. This is particularly relevant in thyroid surgery because the thyroid gland is in close proximity to vital nerves that control our airway and glands that regulate calcium metabolism. Secondly, the newer energy devices have multifunctional properties and are capable of sealing, blunt dissection, grasping and dividing tissue. This is advantageous in thyroid surgery as the operating field has many narrow areas within and the potential reduction in the exchange of instruments facilitates surgery.
Currently, two of these newer generation energy devices are available for use in Singapore General Hospital and National Cancer Centre Singapore. Both devices are similarly priced; one is based on an ultrasonic vibrating blade (UCSD) to cut and coagulate tissue while the other uses bipolar electrical energy and pressure to form a seal and a micro blade to divide the sealed tissue (EBVS). To date, clinical studies comparing both devices have only been done on animal models and focus on sealing times in animal blood vessels.
We aim to compare the effectiveness of these two newer generation energy devices in thyroid surgery by looking at the incidence of post surgical complications, post operative drainage as well as the ease of use as reflected in the operating time.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Harmonic | Active Comparator | Harmonic scalpel uses ultrasound technology to coagulate and to cut tissues. |
|
| Small Jaw | Active Comparator | Small Jaw device uses bipolar electrical energy and pressure to form a seal and a micro blade to divide the sealed tissues. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Harmonic Scalpel (Ethicon Endo-Surgery, USA) | Device |
| ||
| Ligasure Small Jaw (Covidien, USA) |
| Measure | Description | Time Frame |
|---|---|---|
| Duration of Surgery | Kife to skin time to closure time. | Day 1: Day of Surgery |
| Bleeding | Measured blood loss during surgery including suction amount minus the irrigation fluid used as well as the number of gauzes. Drain amount is also recorded postoperatively | Day 1 and on day of drain removal. |
| Measure | Description | Time Frame |
|---|---|---|
| Post op complications | Voice hoarseness, adverse events, stridor, difficulty breathing and other common complications of thyroid surgery are recorded. | Day 2 |
| Ease of use | Surgeon's comment on ease of use, number of nerve identified, number of parathyroid gland identified, staff's inputs on ease of use. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gopal Iyer, Consultant | National Cancer Centre, Singapore | Principal Investigator |
| Jeremy Ng, Consultant | Singapore General Hospital | Principal Investigator |
| Khoon Hiang Tan, Senior Consultant | National Cancer Centre, Singapore | Principal Investigator |
| Chye Ngian Tan, Consultant | National Cancer Centre, Singapore | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Singapore General Hospital | Singapore | 169608 | Singapore | |||
| National Cancer Centre Singapore |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 18831673 | Background | Lamberton GR, Hsi RS, Jin DH, Lindler TU, Jellison FC, Baldwin DD. Prospective comparison of four laparoscopic vessel ligation devices. J Endourol. 2008 Oct;22(10):2307-12. doi: 10.1089/end.2008.9715. | |
| 12799888 | Background | Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc. 2003 Aug;17(8):1228-30. doi: 10.1007/s00464-002-8833-7. Epub 2003 Jun 13. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D013959 | Thyroid Diseases |
| ID | Term |
|---|---|
| D004700 | Endocrine System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
|
| Day 1 |
| Vocal chords on nasal scope inspection | Nasal scope will be done for all subjects at 2-week post operative. If normal, subject does not need to undergo the 2nd nasal scope at 3-month visit. | Day 15 and up to 3-months post-op |
| Ease of use | Measure interruption to device use, absolute failure that necessitates equipment changes, incomplete hemostasis requiring additional tying with silk sutures. | Day 1 |
| Singapore |
| 169610 |
| Singapore |
| 21072688 | Background | Rahbari R, Mathur A, Kitano M, Guerrero M, Shen WT, Duh QY, Clark OH, Kebebew E. Prospective randomized trial of ligasure versus harmonic hemostasis technique in thyroidectomy. Ann Surg Oncol. 2011 Apr;18(4):1023-7. doi: 10.1245/s10434-010-1251-5. Epub 2010 Nov 12. |
| 31512024 | Derived | Lee SH, Nguyen TK, Ong WS, Haaland B, Tay GC, Tan NC, Tan HK, Ng JCF, Iyer NG. Comparing the Utility and Surgical Outcomes of Harmonic Focus Ultrasonic Scalpel with Ligasure Small Jaw Bipolar Device in Thyroidectomies: A Prospective Randomized Controlled Trial. Ann Surg Oncol. 2019 Dec;26(13):4414-4422. doi: 10.1245/s10434-019-07806-w. Epub 2019 Sep 11. |