Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Biliary obstruction is importantly influencing quality of life and survival of patients suffering from primary or secondary bile duct malignancies. The aim of this retrospective data analysis is to evaluate endoscopic radiofrequency ablation (RFA) with the HabibTM EndoHBP catheter for the treatment of malignant biliary obstruction. RFA procedures performed in Austria so far will be analyzed with regard to feasibility and safety of the technique. Therefore, the following parameters will be assessed: (among others) technical failures during the RFA procedure, complications during the RFA procedure, hospital stay, adverse events during hospital stay and until first clinical control after discharge (an expected average of 4 weeks after RFA procedure), 30-day and 90-day mortality. The results of this study should help to better understand important aspects of biliary RFA which may positively influence future applications of this method.
Introduction
Biliary obstruction is the most relevant life limiting factor in patients suffering from primary or secondary bile duct malignancies. Underlying tumors, such as extrahepatic cholangiocarcinoma (CCa) of Klatskin type, pancreatic adenocarcinoma or metastases of colorectal cancer, are often diagnosed at an advanced stage when presenting with biliary obstruction. This mostly restricts treatment strategies to palliative management. Within this setting the prevention of biliary complications like jaundice, cholangitis or cholangiosepsis is one of the therapeutic key factors to extend survival and maintain quality of life [De Groen, Skipworth]. Endoscopic stenting of the biliary tract is an easy and safe approach to restore biliary drainage [Smith]. Self-expanding metal stents are preferred to plastic stents because of the lower risk of stent occlusion [Kaassis, Soderlund]. In addition to stenting endoscopic therapies that directly affect the local tumor mass, have been developed within the past years. First of all, photodynamic therapy using different photosensitizers has shown promising results for the reduction of tumor size and maintenance of biliary drainage [Ortner, Zoepf]. However, the patient management for this treatment involving peri-interventional photosensitivity remains cumbersome.
Recently, an endoscopically applicable radiofrequency catheter for the biliary tract, the so called HabibTM EndoHBP catheter, was introduced into the market. It uses bipolar electrical energy for tissue coagulation and can be applied without any special patient preparation in the context of an endoscopic retrograde cholangiopancreatography (ERCP) examination. RFA is well known from transcutaneous applications, where it already proved to be effective as a treatment option for hepatocellular carcinoma or intrahepatic CCa [Minami]. The new HabibTM EndoHBP catheter was already evaluated ex vivo [Itoi] and showed promising results concerning safety and prevention of stent occlusion in the context of one small retrospective clinical study [Steel].
Primary objective
Feasibility and safety of endoscopic radiofrequency ablation with the HabibTM EndoHBP catheter for the treatment of malignant biliary obstruction
Study Design
Retrospective analysis of prospectively gained clinical data
Primary endpoint
Technical failures during the RFA procedure
Secondary endpoints
Study Population
All patients who underwent endoscopic radiofrequency ablation with the HabibTM EndoHBP as a treatment for malignant biliary obstruction between November 2010 and December 2012 in Austria.
Methods
Endoscopic examination report databases will be screened for "radiofrequency ablation" in the context of an "endoscopic retrograde cholangiopancreatography" to identify the mentioned study population. Examination reports, discharge letters and patient curves of the study patients will be screened to yield the following parameters:
Demographics
Underlying disease that led to malignant biliary obstruction
Procedure related parameters
Post-interventional parameters
Data processing will be done after pseudonymization using continuous patient identification numbers. All parameters will be assessed descriptively. For scaled parameters (e.g. age) median and range will be calculated, for nominal parameters (e.g. type of underlying disease) the proportions of sub-items will be reported. Mortality will be assessed creating a Kaplan Meyer curve. 30-day and 90-day mortality will be extrapolated from this curve. All data processing will be done with SPSS 19.0.
Risk/Benefit assessment
Due to its retrospective design this study does not inherit any risk for the study patients.
Expected impact and Outlook
The results of this study may help to better understand the feasibility and safety profile of endoscopic radiofrequency ablation with the HabibTM EndoHBP catheter with potential effects on future applications.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Malignant biliary obstruction | Experimental | All patients who underwent endoscopic radiofrequency ablation with the HabibTM EndoHBP as a treatment for malignant biliary obstruction in Austria between November 2010 and December 2012. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Endoscopic radiofrequency ablation | Procedure | Endoscopic radiofrequency ablation with the HabibTM EndoHBP catheter uses bipolar electrical energy for tissue coagulation and can be applied without any special patient preparation in the context of an endoscopic retrograde cholangiopancreatography (ERCP) examination to treat malignant biliary strictures. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of RFA-procedures with technical failures | The technical feasibility in this study will be specified as ratio of all technically successful RFA-applications to all examinations in which RFA-use was intended. A RFA-application will be classified as technically successful if it is possible to introduce the RFA-catheter into the biliary system, place it adequately accross the malignant stricture, apply RFA-energy and withdraw the RFA-catheter after RFA-application. | During the respective RFA-examination (an expected average of 1 hour) |
| Measure | Description | Time Frame |
|---|---|---|
| Number of patients with interventional complications | Clinically relevant complications occuring during the use of RFA, defined as any adverse change from the subject's baseline condition, which is considered to be clinically relevant by the physician, whether or not considered related to the medical device (e.g. bleeding, perforation). | During the respective RFA-procedure (an expected average of 1 hour) |
| Measure | Description | Time Frame |
|---|---|---|
| Hospital stay | Duration of hospitalization after the performance of RFA. | Inpatient stay after RFA-procedure (an expected average of 5 days) |
| Number of patients with Adverse events as a Measure of Safety and Tolerability |
All patients who underwent endoscopic radiofrequency ablation with the HabibTM EndoHBP as a treatment for malignant biliary obstruction in Austria between November 2010 and December 2012.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Werner Dolak, MD | Medical University of Vienna, Department of Internal Medicine III, Division of Gastroenterologie and Hepatologie | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical University of Vienna, Department of Internal Medicine III, Division of Gastroenterology and Hepatology | Vienna | Austria |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 10536130 | Background | de Groen PC, Gores GJ, LaRusso NF, Gunderson LL, Nagorney DM. Biliary tract cancers. N Engl J Med. 1999 Oct 28;341(18):1368-78. doi: 10.1056/NEJM199910283411807. No abstract available. | |
| 21933219 | Background | Skipworth JR, Olde Damink SW, Imber C, Bridgewater J, Pereira SP, Malago M. Review article: surgical, neo-adjuvant and adjuvant management strategies in biliary tract cancer. Aliment Pharmacol Ther. 2011 Nov;34(9):1063-78. doi: 10.1111/j.1365-2036.2011.04851.x. Epub 2011 Sep 20. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001661 | Biliary Tract Neoplasms |
| ID | Term |
|---|---|
| D004067 | Digestive System Neoplasms |
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D001660 | Biliary Tract Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D002760 | Cholangiopancreatography, Endoscopic Retrograde |
| ID | Term |
|---|---|
| D002758 | Cholangiography |
| D011860 | Radiography, Abdominal |
| D011859 | Radiography |
| D003952 | Diagnostic Imaging |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Endoscopic retrograde cholangiopancreatography (ERCP) | Procedure | ERCP is used to guide the RFA-catheter under radiological control to the location of the malignant stricture. |
|
| HabibTM EndoHPB catheter | Device | Used to apply radiofrequency energy to the malignant biliary stricture (see also intervention "endoscopic radiofrequency ablation") |
|
Adverse events occuring within 30 days after the RFA-procedure, defined as any adverse change from the subject's baseline condition, i.e. any unfavorable and unintended sign including an abnormal laboratory finding, symptom or disease which is considered to be clinically relevant by the physician, whether or not considered related to the medical device.
| During hospital stay and until first clinical control after discharge (an expected average of 4 weeks after RFA procedure) |
| Mortality | Deaths occuring within 30 and 90 days after the RFA-procedure. | 30 days and 90 days after RFA-procedure (calculating 30- and 90-day mortality rate), assessed retrospectively by screening clinical reports (including death reports) of the study patients on average 1 year after RFA-procedure |
| 7996958 | Background | Smith AC, Dowsett JF, Russell RC, Hatfield AR, Cotton PB. Randomised trial of endoscopic stenting versus surgical bypass in malignant low bileduct obstruction. Lancet. 1994 Dec 17;344(8938):1655-60. doi: 10.1016/s0140-6736(94)90455-3. |
| 12556780 | Background | Kaassis M, Boyer J, Dumas R, Ponchon T, Coumaros D, Delcenserie R, Canard JM, Fritsch J, Rey JF, Burtin P. Plastic or metal stents for malignant stricture of the common bile duct? Results of a randomized prospective study. Gastrointest Endosc. 2003 Feb;57(2):178-82. doi: 10.1067/mge.2003.66. |
| 16733114 | Background | Soderlund C, Linder S. Covered metal versus plastic stents for malignant common bile duct stenosis: a prospective, randomized, controlled trial. Gastrointest Endosc. 2006 Jun;63(7):986-95. doi: 10.1016/j.gie.2005.11.052. |
| 14598251 | Background | Ortner ME, Caca K, Berr F, Liebetruth J, Mansmann U, Huster D, Voderholzer W, Schachschal G, Mossner J, Lochs H. Successful photodynamic therapy for nonresectable cholangiocarcinoma: a randomized prospective study. Gastroenterology. 2003 Nov;125(5):1355-63. doi: 10.1016/j.gastro.2003.07.015. |
| 16279895 | Background | Zoepf T, Jakobs R, Arnold JC, Apel D, Riemann JF. Palliation of nonresectable bile duct cancer: improved survival after photodynamic therapy. Am J Gastroenterol. 2005 Nov;100(11):2426-30. doi: 10.1111/j.1572-0241.2005.00318.x. |
| 21179308 | Background | Minami Y, Kudo M. Radiofrequency ablation of hepatocellular carcinoma: Current status. World J Radiol. 2010 Nov 28;2(11):417-24. doi: 10.4329/wjr.v2.i11.417. |
| 22038500 | Background | Itoi T, Isayama H, Sofuni A, Itokawa F, Tamura M, Watanabe Y, Moriyasu F, Kahaleh M, Habib N, Nagao T, Yokoyama T, Kasuya K, Kawakami H. Evaluation of effects of a novel endoscopically applied radiofrequency ablation biliary catheter using an ex-vivo pig liver. J Hepatobiliary Pancreat Sci. 2012 Sep;19(5):543-7. doi: 10.1007/s00534-011-0465-7. |
| 21184881 | Background | Steel AW, Postgate AJ, Khorsandi S, Nicholls J, Jiao L, Vlavianos P, Habib N, Westaby D. Endoscopically applied radiofrequency ablation appears to be safe in the treatment of malignant biliary obstruction. Gastrointest Endosc. 2011 Jan;73(1):149-53. doi: 10.1016/j.gie.2010.09.031. |
| D004066 |
| Digestive System Diseases |
| D019937 |
| Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
| D003938 | Diagnostic Techniques, Digestive System |
| D016145 | Endoscopy, Digestive System |
| D004724 | Endoscopy |
| D003949 | Diagnostic Techniques, Surgical |
| D013505 | Digestive System Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
| D019060 | Minimally Invasive Surgical Procedures |