The investigators are proposing to continue investigation to improve the accuracy of the SpHb (continuous hemoglobin monitoring device) by administering an intermediate acting digital nerve block in the finger connected to the SpHb, specifically bupivacaine 0.25% in patients undergoing spine surgery. Bupivacaine is FDA approved and in routine use.
Patients undergoing spine surgery will be randomized to receive (or not) the bupivacaine digital block on the finger attached to the new limited release version of the hemoglobin sensor, RevG. The SpHb reading will be compared to a blood hemoglobin level analyzed in the UCSF Clinical Laboratories.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| bupivacaine digital nerve block | Experimental | Patients undergoing spine surgery will have a 50/50 chance of being randomized to receive a bupivacaine 0.25% (2 milliliters total) intermediate-acting digital nerve block. |
|
| No bupivacaine digital nerve block | No Intervention | Patients undergoing spine surgery will have a 50/50 chance of being randomized to not receive a bupivacaine 0.25% (2 milliliters total) intermediate-acting digital nerve block. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| intermediate-acting digital nerve block | Other | non-therapeutic Bupivacaine digital nerve block to assess effect on accuracy of diagnostic readings |
|
| Measure | Description | Time Frame |
|---|---|---|
| SpHb (continuous hemoglobin monitor reading) minus tHb (clinical laboratory determined hemoglobin value). | Use of a longer acting local anesthetic (bupivacaine) for the digital nerve block will result in SpHb (the non-invasive hemoglobin device) being sufficiently accurate for blood transfusion decisions(≤ 1.0 g/dL difference) To assess if using an intermediate-acting digital nerve block will improve the accuracy of the SpHb readings when compared to a blood hemoglobin level analyzed in the UCSF Clinical Laboratories intermittently during the patient's surgery. | Intermittent (about hourly) hemoglobin checks throughout the surgery. |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Ronald D Miller, MD, MS | University of California, San Francisco | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of California, San Francisco | San Francisco | California | 94143 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided