Minimal invasive monitoring systems of central hemodynamics are gaining increasing popularity. The present study investigates the precision of the esophageal doppler (CardioQ) derived cardiac output and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring CO during steady state and with induced hemodynamic changes in patients scheduled for elective cardiac surgery.
Twenty-five patients are planned to be enrolled. After induction of anesthesia, insertion of the PAC and the esophageal-doppler probe, the patient are placed in the following successive positions: a) supine, b) head-down tilt, c) head-up tilt, d) supine, e) supine with phenylephrine administration f) pace heart rate 80 bpm, g) pace heart rate 110 bpm, and CO are measured simultaneously using the CardioQ and PAC TD.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| induced changes in hemodynamics | Experimental | Twenty-five patients are planned enrolled. After induction of anesthesia, insertion of the PAC and the CardioQ probe, the patient are placed in the following successive positions: a) supine, b) head-down tilt, c) head-up tilt, d) supine, e) supine with phenylephrine administration f) pace heart rate 80 bpm, g) pace heart rate 110 bpm. CO are measured simultaneously using the CardioQ and thermodilution technique. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| induced changes in hemodynamics | Other | Twenty-five patients are planned enrolled. After induction of anesthesia, insertion of the PAC and the CardioQ probe, the patient are placed in the following successive positions: a) supine, b) head-down tilt, c) head-up tilt, d) supine, e) supine with phenylephrine administration f) pace heart rate 80 bpm, g) pace heart rate 110 bpm. CO are measured simultaneously using the TEE and thermodilution technique. |
| Measure | Description | Time Frame |
|---|---|---|
| Agreement of cardiac output determined with CardioQ, compared with thermodilution | Data are collected for each patient in the perioperative period. Patients are followed in the first 24 hours. Data will after inclusion of the last data be analysed and appropiate statistics aplied. | Data are collected in the perioperative period (30min.) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
-
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Rigshospitalet, University of Copenhagen | Copenhagen | Capital Region | 2100 | Denmark | ||
| Department of Cardiothoracic anesthesiology; Rigshospitalet |
Not provided
| ID | Term |
|---|---|
| D006439 | Hemodynamics |
| ID | Term |
|---|---|
| D002320 | Cardiovascular Physiological Phenomena |
| D002943 | Circulatory and Respiratory Physiological Phenomena |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Copenhagen |
| 2100 |
| Denmark |