The investigators are comparing the range of movements the knees of patients who had total knee replacement surgery for knee osteoarthritis. In the study arm, the implant used was a Sigma Cruciate Retaining (CR) Press Fit Condylar (PFC) 150, which is a high flexion knee system designed to combine function with wear resistance. It can accommodate up to 150 degrees of knee flexion. In the cohort arm, the implant used was the standard Sigma CR which can accommodate up to 120 degrees of flexion.
Both sets of patients will undergo routine post-operative follow up in clinic. The study involves patients who had their surgery more than 2 years ago. We assess their range of movement using fluoroscopy. They are asked to perform lunges, squats and climbing up and down 3 steps. The fluoroscopic images are then analysed to assess their individual range of movements.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| PFC CR 150 total knee implant | Study group implant: PFC CR 150 Control group implant: PFC CR standard | ||
| PFC CR Standard | study group implant: PFC CR 150 control group implant: PFC CR Standard |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Flexion-extension range of movement of operated knee | Fluoroscopic studies are done as patient perform lunges, squats and climb up and down stairs. | 2 years after their total knee replacement surgery |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
All patients who underwent total knee replacement surgery who received either the PFC CR 150 knee implants or the PFC CR standard knee implant
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Dr Seng Jin Yeo, MBBS FRCS | Singapore General Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Singapore General Hospital | Singapore | Singapore | 168751 | Singapore |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17568418 | Background | Nicholls RL, Schirm AC, Jeffcote BO, Kuster MS. Tibiofemoral force following total knee arthroplasty: comparison of four prosthesis designs in vitro. J Orthop Res. 2007 Nov;25(11):1506-12. doi: 10.1002/jor.20438. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D020370 | Osteoarthritis, Knee |
| ID | Term |
|---|---|
| D010003 | Osteoarthritis |
| D001168 | Arthritis |
| D007592 | Joint Diseases |
| D009140 | Musculoskeletal Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| D012216 |
| Rheumatic Diseases |