In patients under mechanical ventilation, Usefulness of dynamic indices based on the heart-lung interactions for guiding volume resuscitation has been well validated. Recently, validity of pulse pressure variation (PPV) has been also reported to predict fluid responsiveness. Oesophageal Doppler (OED) allows continuous monitoring of several important hemodynamic variables. Of the OED variables, corrected flow time (FTc) has been evaluated and used as a preload index, and has been reported to predict fluid responsiveness. Prone position caused physiologic and hemodynamic changes and influenced the predictability and cut-off values of SVV and PPV for fluid responsiveness. In this prospective controlled study, the investigators evaluated the validity of PPV and FTc as predictors for fluid responsiveness in supine and prone position in patients undergoing posterior lumbar spinal fusion
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| corrected flow time | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 1.Esophageal doppler monitor | Device | 1.Esophageal doppler monitor (CARDIO Q®, DELTEX MEDICAL. Brighton, U. K.)-inserted into the esophagus and positioned approximately 35-40 cm from the teeth. The position of OED prove was confirmed by continuously measuring blood flow velocity in the descending thoracic aorta and focused to find the optimum peak velocity and waveform signal. |
| Measure | Description | Time Frame |
|---|---|---|
| PPV(Pulse pressure variation) | 15 minutes after induction of anaesthesia at the supine position | |
| FTc(corrected flow time) | 15 minutes after induction of anaesthesia at the supine position |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Anesthesiology and Pain Medicine and Anesthesia | Seoul | Seoul | 120-752 | South Korea |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23274783 | Derived | Yang SY, Shim JK, Song Y, Seo SJ, Kwak YL. Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position. Br J Anaesth. 2013 May;110(5):713-20. doi: 10.1093/bja/aes475. Epub 2012 Dec 28. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| 2. philips Intelivue MP70 monitors | Device | 2.philips Intelivue MP70 monitors (Intellivue MP70, philips medical Systems, Suresnes, France) -a radial arterial cannula was inserted and arterial pressure waveforms were monitored through Philips Intelivue MP70 monitors. In the monitor, PPVauto was displayed in real-time. It based on automatic detection algorithms, kernel smoothing, and rank-order filters. |
|
|