Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| GO70151 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| VA Office of Research and Development | FED |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to test an innovative, advanced FNS microstimulator technology developed by the Alfred Mann Foundation (Santa Clarita, CA) called, the Radio Frequency Microstimulation (RFM) Gait System that promises to provide FNS training for restoration of functional gait components in a manner at least as efficacious as current investigational FNS systems. The design features of the RFM Gait System are intended to address the problems with the current FNS systems. The RFM implant devices are small enough to be inserted using only a 5 mm incision[3]. Because both the electrode (anode and cathode) are contained within the microstimulator, there are no lead wires traversing the skin, joints, or torso/limb junctures. Individual RFMs can be inserted at the motor points and nerves of each of the paretic muscles in the involved limb and coordinated using radio frequency technology.
The primary objective (Aim I) of this study is to evaluate whether the RFM Gait System can restore the capability to perform the components of gait required for safe, functional walking, for patients in the chronic phase after stroke (> 12 months). We will assess the treatment provided by the RFM system at the Cleveland VA compared to the FNS percutaneous Schreiner electrodes and custom-designed controller previously investigated by the investigators.
The similarities between the RFM-based and percutaneous FNS systems will be assessed using six gait components required for the execution of functional, safe gait, which are lower limb strength, coordination, an index of walking endurance, muscle tone, walking speed, and quality of life.
The secondary objective of this study is to test the technological performance and safety of the RFM Gait System. Measures of technology performance and safety include implantation time; anchoring capability at the motor point of the muscle; reliability of the RFMs during use; reliability of electrical performance of the system; comfort of the system (with stimulation off); comfort of the electrical stimulus.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Implanted | Experimental | All participants. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Radio-frequency Microstiumulator | Device | All participants will receive leg implants and will be trained first in the clinical and subsequently perform stimulation-assisted exercises in the home - for an overall duration of 6 months post-implant. Subsequently, exercise programs will continue without stimulation. Patient condition will be assessed at 9, 12 and 24 months post-implant. |
| Measure | Description | Time Frame |
|---|---|---|
| Change from baseline to Month 24 of swing phase gait components and knee control during stance phase with 6 gait components. | The six gait components listed below:
| 24 months |
| Measure | Description | Time Frame |
|---|---|---|
| Change from baseline to Month 24, without stimulation, of four scales and two QOL questionnaires. | The four scales are:Six Minute Walk Test, Manual Muscle Test, Fugl-Meyer Coordination Scale, and the Ashworth Scale. The two QOL questionnaires are: Craig Handicap Assessment & Reporting Technique (CHART) and Stroke Impact Scale (SIS): | 24 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Janis J Daly, PhD, MSPT | Cleveland VA Medical Center | Principal Investigator |
| Robert Ruff, MD, PhD | Cleveland VA Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| VA Medical Center | Cleveland | Ohio | 44106 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 16322492 | Background | Daly JJ, Roenigk K, Holcomb J, Rogers JM, Butler K, Gansen J, McCabe J, Fredrickson E, Marsolais EB, Ruff RL. A randomized controlled trial of functional neuromuscular stimulation in chronic stroke subjects. Stroke. 2006 Jan;37(1):172-8. doi: 10.1161/01.STR.0000195129.95220.77. Epub 2005 Dec 1. | |
| 15465093 | Background |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D010291 | Paresis |
| ID | Term |
|---|---|
| D009461 | Neurologic Manifestations |
| D009422 | Nervous System Diseases |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D016503 | Drug Delivery Systems |
| ID | Term |
|---|---|
| D004358 | Drug Therapy |
| D013812 | Therapeutics |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Daly JJ, Ruff RL. Feasibility of combining multi-channel functional neuromuscular stimulation with weight-supported treadmill training. J Neurol Sci. 2004 Oct 15;225(1-2):105-15. doi: 10.1016/j.jns.2004.07.006. |
| 11732829 | Background | Daly JJ, Kollar K, Debogorski AA, Strasshofer B, Marsolais EB, Scheiner A, Snyder S, Ruff RL. Performance of an intramuscular electrode during functional neuromuscular stimulation for gait training post stroke. J Rehabil Res Dev. 2001 Sep-Oct;38(5):513-26. |