Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Nitrous oxide (N2O) has been used for the treatment of labor pains for over 150 years. The longevity of its use in clinical practice can be attributed to its excellent safety profile, ease of administration, and familiarity of use among health-care providers. Sedara is a self-administered 50% N2O, 50% oxygen gas mixture with pain relieving and anxiety reducing properties recently available for use in the United States (US) to treat various painful clnical situations, including labor pains.
In the US, epidural or intravenous administration of narcotic medications is one of the most common and frequently requested treatments for patients experiencing labor pains. Although generally considered safe, complications are common with epidurals, including fetal distress, low blood pressure in the mother, respiratory distress, and headache. In our hospital system, the use of the synthetic intravenous painkiller, Butorphanol, is a mainstay of treatment for labor pains. It too can have undesirable side effects in the mother, including low blood pressure and breathing problems.
Because Sedara has until recently been unavailable in the US, studies comparing its efficacy with other agents for labor pain have been confined to Europe, predominantly in the United Kingdom. Several studies have investigated the efficacy of Sedara versus inhalation and intravenous anesthetics in various countries. We have obtained several Sedara devices for use in the West Penn Allegheny Health System (WPAHS) Department of Anesthesiology and would like to examine its efficacy in our target population of women experiencing pain during early labor.
Hypothesis - Sedara will provide equivalent or superior pain relief among term, adult parturients in early labor (less than 5cm cervical dilation) compared to intravenous butorphanol.
Primary aim - Compare Sedara versus butorphanol in a single-blinded randomized trial with the main outcome measure being reduction in labor pains at various time intervals.
Our findings may be significant in terms of improving safety and efficacy of pain relief among women experienceing labor pains. Given that Sedara has not been previously studied in the US, the results may influence current obstetrical and pain management practices.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Butorphanol | Experimental | The main study arm will be examining how well a 50% Nitrous Oxide/50% Oxygen gas mixture is in reducing labor pains in term labor patients with less than 5 cm cervical dilation, compared to 2mg of Butorphanol (a common synthetic opiod used for labor pains in this setting). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 50% Nitrous Oxide/50% Oxygen | Drug | The gas mixture is provided via the Sedara portable gas delivery system. This system is equipped with a non-rebreather mask which the patient holds over their mouth and nose. The delivery of the gas is only triggered by the patient's spontaneous breath. The gas machine will be provided to the patient to use as much as they like during the 60 minutes data collection period. The only dose which the machine allows to be administered is 50% Nitrous Oxide/50% oxygen. |
| Measure | Description | Time Frame |
|---|---|---|
| Pain relief | The primary outcome measure of pain relief will be measured using a 100mm visual analog scale (VAS) immediately prior to administration of the test medication (either Sedara or butorphanol) and again at 5, 15, 30 and 60 minutes following the medication start time. | 60 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| Nausea, Sedation, Satisfaction | Secondary outcome measures collected include maternal reported level nausea, sedation, and overall satisfaction with analgesia using the Visual Analog Scores Scale at 0, 5, 15, 30 and 60 minutes. | 60 minutes |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Helene Finegold, MD | Associate Residency Program Director | Principal Investigator |
| Christopher Troianos, MD | Residency Program Director | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| West Penn Hospital | Pittsburgh | Pennsylvania | 152064231 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21451402 | Background | Volmanen P, Palomaki O, Ahonen J. Alternatives to neuraxial analgesia for labor. Curr Opin Anaesthesiol. 2011 Jun;24(3):235-41. doi: 10.1097/ACO.0b013e328345ad18. | |
| 12011877 | Background | Rosen MA. Nitrous oxide for relief of labor pain: a systematic review. Am J Obstet Gynecol. 2002 May;186(5 Suppl Nature):S110-26. doi: 10.1067/mob.2002.121259. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D048949 | Labor Pain |
| ID | Term |
|---|---|
| D010146 | Pain |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| 19283736 | Background | Maslekar S, Gardiner A, Hughes M, Culbert B, Duthie GS. Randomized clinical trial of Entonox versus midazolam-fentanyl sedation for colonoscopy. Br J Surg. 2009 Apr;96(4):361-8. doi: 10.1002/bjs.6467. |
| 20677364 | Background | Young P, Emery NC, Reisin R. Epidural analgesia for labor and delivery. N Engl J Med. 2010 Jul 22;363(4):395. No abstract available. |
| 8598984 | Background | Viscomi CM. Randomized trial of epidural versus intravenous analgesia during labor. Obstet Gynecol. 1996 Mar;87(3):480-2. doi: 10.1016/0029-7844(96)82976-0. No abstract available. |
| 14712952 | Background | Dickinson JE, Paech MJ, McDonald SJ, Evans SF. Maternal satisfaction with childbirth and intrapartum analgesia in nulliparous labour. Aust N Z J Obstet Gynaecol. 2003 Dec;43(6):463-8. doi: 10.1046/j.0004-8666.2003.00152.x. |
| 17158129 | Background | Yeo ST, Holdcroft A, Yentis SM, Stewart A, Bassett P. Analgesia with sevoflurane during labour: ii. Sevoflurane compared with Entonox for labour analgesia. Br J Anaesth. 2007 Jan;98(1):110-5. doi: 10.1093/bja/ael327. |
| 15777291 | Background | Volmanen P, Akural E, Raudaskoski T, Ohtonen P, Alahuhta S. Comparison of remifentanil and nitrous oxide in labour analgesia. Acta Anaesthesiol Scand. 2005 Apr;49(4):453-8. doi: 10.1111/j.1399-6576.2005.00639.x. |
| 19943458 | Background | Talebi H, Nourozi A, Jamilian M, Baharfar N, Eghtesadi-Araghi P. Entonox for labor pain: a randomized placebo controlled trial. Pak J Biol Sci. 2009 Sep 1;12(17):1217-21. doi: 10.3923/pjbs.2009.1217.1221. |
| 9835471 | Background | Kelly AM. Does the clinically significant difference in visual analog scale pain scores vary with gender, age, or cause of pain? Acad Emerg Med. 1998 Nov;5(11):1086-90. doi: 10.1111/j.1553-2712.1998.tb02667.x. |
| 12811707 | Background | Yamamoto LG, Nomura JT, Sato RL, Ahern RM, Snow JL, Kuwaye TT. Minimum clinically significant VAS differences for simultaneous (paired) interval serial pain assessments. Am J Emerg Med. 2003 May;21(3):176-9. doi: 10.1016/s0735-6757(02)42255-3. |
| 14525749 | Background | Lee JS, Hobden E, Stiell IG, Wells GA. Clinically important change in the visual analog scale after adequate pain control. Acad Emerg Med. 2003 Oct;10(10):1128-30. doi: 10.1111/j.1553-2712.2003.tb00586.x. |