Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Device was sunset from the market in May2015. No longer need for long term data.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This was a prospective, non-randomized, multi-center, non-interventional post-market study. The study was a post-market long-term follow-up study based on the same cohort of patients (148 patients) enrolled in a previous investigational study from March 2007 to December 2009 (ATS 3f Enable™ Aortic Bioprosthesis Model 6000, number S2005) involving 10 European sites. Patient follow-up took place on a yearly basis up to 10 years after the implant/enrollment. The primary objective of this study was to evaluate the safety and effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis during long-term follow-up.
As this was an observational study, safety and efficacy data were summarized and described. There was no statistically powered study hypothesis.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Aortic Valve Replacement | Device | Aortic Valve Replacement with Medtronic ATS 3f ENABLE® Aortic Bioprosthesis Model 6000 |
| Measure | Description | Time Frame |
|---|---|---|
| Assess the Long-term safety of the Medtronic ATS Enable Aortic Bioprosthesis | Long-term safety will be assessed by collecting following reported adverse events addressed: Migration, Valve Related Thromboembolism, Valvular thrombosis, Haemorrhage, Perivalvular Leak, Endocarditis, Hmolysis, Structural valve Deterioration, Non-Structural Dysfunction, Reoperation, Explant and Death. | 10 Years Post-Procedure |
| Assess the Long-term Clinical Effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis: NYHA Functional Classification | Long-term clinical effectiveness of the Aortic Bioprosthesis will be assessed by collecting the NYHA-class of enrolled subjects over a period of time, following surgery. | 10 Years Post-Procedure |
| Long-term Effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis: Hemodynamic Performance | Hemodynamic performance of the Aortic Bioprosthesis will be assessed by specific echocardiography measurements | 10 Years Post-Procedure |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients who were enrolled and implanted during the previous investigational study named "ATS 3f Enable™ Aortic Bioprosthesis Model 6000" (study number S2005).
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Thierry Carrel, Prof. | Inselspital Bern, Klinik für Herz-und Gefasschirurgie, CH-3010 Bern | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Johann Wolfgang Goethe University | Frankfurt | D-60590 | Germany | |||
| University Medical Center Freiburg |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21342776 | Background | Martens S, Sadowski J, Eckstein FS, Bartus K, Kapelak B, Sievers HH, Schlensak C, Carrel T. Clinical experience with the ATS 3f Enable(R) Sutureless Bioprosthesis. Eur J Cardiothorac Surg. 2011 Sep;40(3):749-55. doi: 10.1016/j.ejcts.2010.12.068. Epub 2011 Feb 20. | |
| 24787699 | Background | Englberger L, Carrel TP, Doss M, Sadowski J, Bartus K, Eckstein FF, Asch FM, Martens S. Clinical performance of a sutureless aortic bioprosthesis: five-year results of the 3f Enable long-term follow-up study. J Thorac Cardiovasc Surg. 2014 Oct;148(4):1681-7. doi: 10.1016/j.jtcvs.2014.03.054. Epub 2014 Apr 4. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001024 | Aortic Valve Stenosis |
| D001022 | Aortic Valve Insufficiency |
| ID | Term |
|---|---|
| D000082862 | Aortic Valve Disease |
| D006349 | Heart Valve Diseases |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D065467 | Transcatheter Aortic Valve Replacement |
| ID | Term |
|---|---|
| D019918 | Heart Valve Prosthesis Implantation |
| D006348 | Cardiac Surgical Procedures |
| D013504 | Cardiovascular Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
Not provided
Not provided
Not provided
Not provided
Not provided
| Freiburg im Breisgau |
| 79106 |
| Germany |
| University Medical Center Kiel | Kiel | 24105 | Germany |
| Jagellonian University, John Paul the II Hospital | Krakow | 31-202 | Poland |
| Universitätsspital Basel | Basel | CH-4031 | Switzerland |
| Inselspital Bern | Bern | CH-3010 | Switzerland |
| D014694 |
| Ventricular Outflow Obstruction |
| D019919 | Prosthesis Implantation |
| D019616 | Thoracic Surgical Procedures |