To comprehensively assess the precision and agreement of anterior corneal power measurements using 8 different devices.
Volunteers with healthy corneas will be measured by different instruments to detect their anterior corneal power. Only the right eye of each subject was selected. Measurements were repeated in the second session scheduled 1 to 2 weeks later.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Corneal power measurement | All recruited volunteers in present study, that underwent corneal power measurement with 8 different instruments |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Corneal power measurement | Device | All subjects will be underwent a full ophthalmic examination including vision, auto- and subjective refraction, slit-lamp examination, non-contact tonometry, corneal power measurements with the 8 devices and fundus examination. |
| Measure | Description | Time Frame |
|---|---|---|
| Flat corneal power | The intrasession repeatability and intersession reproducibility of flat corneal curvature measurements by using the 8 commercially available instruments. | 2 weeks |
| Steep corneal power | The intrasession repeatability and intersession reproducibility of Steep corneal curvature measurements by using the 8 commercially available instruments. | 2 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Vector power J0 | The intrasession repeatability and intersession reproducibility of vector power J0 measurements by using the 8 commercially available instruments. | 2 weeks |
| Vector power J45 | The intrasession repeatability and intersession reproducibility of vector power J45 measurements by using the 8 commercially available instruments. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
The present study's definitions of reproducibility, repeatability and agreement were based on those adopted by the British Standards Institute and the International Organization for Standardization.
Corneal curvature measurement provides crucial information for calculating intraocular lens power,screening and managing corneal refractive surgeries and corneal disease.
Volunteers with healthy corneas will be measured by different instruments to detect their anterior corneal power.Only the right eye of each subject was selected.Measurements were repeated in the second session scheduled 1 to 2 weeks later, at almost the same time as the first session, by the same examiner using the same protocol.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Yifang Feng, MD | Eye Hospital, Wenzhou Medical College, China | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Wenzhou Medical College | Wenzhou | Zhejiang | 325000 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23049823 | Derived | Wang Q, Savini G, Hoffer KJ, Xu Z, Feng Y, Wen D, Hua Y, Yang F, Pan C, Huang J. A comprehensive assessment of the precision and agreement of anterior corneal power measurements obtained using 8 different devices. PLoS One. 2012;7(9):e45607. doi: 10.1371/journal.pone.0045607. Epub 2012 Sep 25. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D009216 | Myopia |
| ID | Term |
|---|---|
| D012030 | Refractive Errors |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| 2 weeks |