The purpose of this research study is to test the function of a subjects implantable cardioverter defibrillator (ICD) function throughout the duration of their heart surgery. ICD function can be altered during some types of heart surgery such as those when a pump (ventricular assist device - VAD) is implanted. The investigators would like to study the mechanism of device and ICD malfunction.
ICD function is typically measured prior to and after surgery. For the study, the investigators will measure ICD lead function multiple times throughout the surgery as well, to determine if and when device malfunction occurs. ICD lead function is measured noninvasively through a specialized computer the same way it is checked in the clinic. In addition, the investigators will test ICD function as they usually do following surgery.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Study Group - Control Group | VAD implantation (study group) or other cardiothoracic surgery (control group) |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| observational study to assess potential changes that may occur in the RV ICD lead function during LVAD implantation and what mechanism may cause those changes in RV ICD lead function | RV ICD lead function will be measured throughout LVAD placement , at 1 week post LVAD placement, and 3 months post LVAD placement Description: |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients with wireless ICDs undergoing VAD implantation (study group) or other cardiothoracic surgery (control group) will be included.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jordana Kron, MD | Virginia Commonwealth University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Virginia Commonwealth University | Richmond | Virginia | 23298 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29766894 | Derived | Hu YL, Kasirajan V, Tang DG, Shah KB, Koneru JN, Grizzard JD, Ellenbogen KA, Kron J. Prospective Evaluation of Implantable Cardioverter-Defibrillator Lead Function During and After Left Ventricular Assist Device Implantation. JACC Clin Electrophysiol. 2016 Jun;2(3):343-354. doi: 10.1016/j.jacep.2016.01.008. Epub 2016 Mar 23. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided