Iron overload is a severe complication of multiple blood transfusions. As the body has no physiologic mechanism for clearing iron, repeated transfusions cause iron accumulation in organs and lead to iron toxicity. Accurate assessment of iron overload is paramount to quantify excessive iron accumulation and to monitor response to iron chelation therapy. Magnetic resonance imaging (MRI) methods have been used to noninvasively measure hepatic iron concentration (HIC). Although MRI-based measurements of transverse relaxation rates (R2 and R2*) accurately predict biopsy-proven HICs below 15 mg Fe/g, previous studies have shown that their precision is limited for HICs above 15 mg Fe/g and inaccurate above 25 mg Fe/g. Current R2* gradient-echo (GRE) MR techniques fail occasionally for very high iron overloads (HIC ~ 15-25 mg Fe/g) and always for massive iron overloads (HIC > 25 mg Fe/g) because R2* is so high that the MR signal decays before it can be measured accurately.
Overall accrual: 200 patients
Purpose: To determine if a new MRI (UTE) can measure the amount of iron in the liver of people with large amounts of iron and compare the results with the same patient's liver bx. Estimated patient accrual is 150. It is estimated that 41 of these patients will have clinical indication for liver biopsy.
The MIDAS study is a prospective and non-therapeutic study that will test a new MRI technique for the assessment of iron overload in the liver: the newly developed ultra short echo time (UTE), R2*-UTE. The R2*-UTE technique, developed by St. Jude investigators from the Department of Radiological Sciences, will be first tested in healthy volunteers for feasibility and implementation of the technique. The technique will then be tested in research participants, who will have both the R2*-GRE and the R2*-UTE techniques performed, in addition to a liver biopsy for liver iron quantitation if clinically indicated. Quantitation of liver tissue iron will be done at Mayo Clinic Laboratory in Rochester, Minnesota.
Primary Objective:
Secondary Objectives:
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Iron-overloaded | Other | Patients with iron overload or excessive body iron burden, a serious condition resulting from increased dietary gastro¬intestinal absorption, multiple erythrocyte transfusions, or both. Interventions: R2*-UTE, R2*-GRE, and if clinically indicated, liver biopsy. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| R2*-UTE | Device | Ultra short echo time (UTE) magnetic resonance imaging (MRI). Study participants will undergo an MRI examination of the liver on a 1.5T MRI and a 3T MRI scanner each. Because liver biopsy metal needle fragments could interfere with the MRI measurements, the MRI exams will always precede liver biopsy. Multi-echo GRE sequences will be used to acquire images with increasing TEs. Images of the liver will be obtained in transversal slice orientation through the center of the liver at the level of the origin of the main portal vein. At equivalent slice locations R2*-UTE scans will be performed. |
| Measure | Description | Time Frame |
|---|---|---|
| Hepatic Iron Content in the Liver Using Liver Biopsy | Hepatic iron content in the liver using liver biopsy | up to 30 days after MRI |
| MRI-derived R2* Values Using 1.5T UTE Technique | Hepatic iron content of the liver using MRI-derived 1.5T R2*-UTE measurement, with results in Hz. R2* is a measure obtained with MRI, i.e., MRI R2*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2* value low. T2* is the reciprocal of R2* (R2*= 1/T2*). So, if the signal drops fast, the T2* is low and the R2* is high. In this study, we are measuring the R2* value. The higher the R2*, the more iron in the liver tissue. We can compare the R2* value with that of a liver biopsy to then use the R2* value to tell us how much iron is in the liver without having to biopsy the liver. | Up to 30 days after MRI |
| Measure | Description | Time Frame |
|---|---|---|
| MRI-derived R2* Using 1.5T GRE Technique | MRI-derived R2* Using 1.5T GRE Technique in Hz. R2* is a measure obtained with MRI, i.e., MRI R2*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2* value low. T2* is the reciprocal of R2* (R2*= 1/T2*). So, if the signal drops fast, the T2* is low and the R2* is high. In this study, we are measuring the R2* value. The higher the R2*, the more iron in the liver tissue. We can compare the R2* value with that of a liver biopsy to then use the R2* value to tell us how much iron is in the liver without having to biopsy the liver. |
Not provided
Inclusion Criteria
Exclusion Criteria
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jane Hankins, MD, MS | St. Jude Children's Research Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| St. Jude Children's Research Hospital | Memphis | Tennessee | 38105 | United States |
Not provided
| Label | URL |
|---|---|
| St. Jude Children's Research Hospital | View source |
| Clinical Trials Open at St. Jude | View source |
Not provided
One arm study
Patients within the St. Jude Network (St. Jude Children's Research Hospital, St. Jude Domestic Affiliates, and the adult Hematology and Oncology program at the University of Tennessee Health Sciences Center) who have history of 12 or more lifetime erythrocyte transfusions, and need for liver iron content assessment.
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Arm 1 | All eligible patients with history of 12 or more lifetime erythrocyte transfusions, and need for liver iron content assessment. |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Arm 1 | All eligible patients with history of 12 or more lifetime erythrocyte transfusions, and need for liver iron content assessment |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Hepatic Iron Content in the Liver Using Liver Biopsy | Hepatic iron content in the liver using liver biopsy | Eligible iron-overloaded patients with both liver biopsy measurement and 1.5T R2*-UTE measurement. | Posted | Median | Full Range | mcg | up to 30 days after MRI |
|
|
Time frame for adverse event reporting is 10 days following the last study procedure for eligible patients.
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Iron-overloaded Patients | Eligible iron-overloaded patients with both liver biopsy measurement and 1.5T R2*-UTE measurement |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Infections and infestations | Gastrointestinal disorders | Systematic Assessment |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Anxiety | Psychiatric disorders | Systematic Assessment |
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Jane Hankins, MD | St. Jude Children's Research Hospital | 866-278-5833 | Jane.Hankins@stjude.org |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Jan 11, 2016 | Mar 1, 2019 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D019190 | Iron Overload |
| D000755 | Anemia, Sickle Cell |
| D013789 | Thalassemia |
| D006432 | Hemochromatosis |
| D009369 | Neoplasms |
| ID | Term |
|---|---|
| D019189 | Iron Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
| D000745 | Anemia, Hemolytic, Congenital |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| R2*-GRE | Device | Gradient-echo (GRE) magnetic resonance imaging (MRI). Study participants will undergo an MRI examination of the liver on a 1.5T MRI and a 3T MRI scanner each. Because liver biopsy metal needle fragments could interfere with the MRI measurements, the MRI exams will always precede liver biopsy. Multi-echo GRE sequences will be used to acquire images with increasing TEs. Images of the liver will be obtained in transversal slice orientation through the center of the liver at the level of the origin of the main portal vein. At equivalent slice locations R2*-UTE scans will be performed. |
|
| Liver biopsy | Procedure | Indications for liver biopsy include, but are not limited, to the need to quantify liver tissue iron and the need to obtain histopathological information of the liver tissue. Liver biopsies will only be performed if clinically indicated and will be done only once per patient. The technique to be used is coaxial percutaneous (transcapsular) technique; however, a coaxial transjugular technique may be performed in subjects with increased bleeding diathesis, since it is associated with less hemorrhagic risk. Healthy volunteers will not undergo liver biopsy. |
|
| Up to 30 days after MRI |
| MRI Derived R2* Using 1.5T UTE Technique | MRI-derived R2* value using 1.5T R2*-UTE in Hz. R2* is a measure obtained with MRI, i.e., MRI R2*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2* value low. T2* is the reciprocal of R2* (R2*= 1/T2*). So, if the signal drops fast, the T2* is low and the R2* is high. In this study, we are measuring the R2* value. The higher the R2*, the more iron in the liver tissue. We can compare the R2* value with that of a liver biopsy to then use the R2* value to tell us how much iron is in the liver without having to biopsy the liver. | up to 30 days after MRI |
| R2* Using 1.5T UTE Technique for Patients With Serum Iron and Transferrin Saturation Measurements | MRI-derived R2* value using 1.5T R2*-UTE in Hz for patients who have had serum iron and transferrin saturation measurements. R2* is a measure obtained with MRI, i.e., MRI R2*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2* value low. T2* is the reciprocal of R2* (R2*= 1/T2*). So, if the signal drops fast, the T2* is low and the R2* is high. In this study, we are measuring the R2* value. The higher the R2*, the more iron in the liver tissue. We can compare the R2* value with that of a liver biopsy to then use the R2* value to tell us how much iron is in the liver without having to biopsy the liver. | Up to 30 days after MRI |
| Serum Iron Measurements Compared With 1.5T R2* UTE | Serum iron measurements from eligible patients had 1.5T R2*-UTE and serum iron and transferrin saturation measurements. | Up to 30 days after MRI |
| Transferrin Saturation Measurements | Iron Transferrin Saturation in % measurements Transferrin Saturation measurements from eligible patients had 1.5T R2*-UTE and serum iron and transferrin saturation measurements. | Up to 30 days after MRI |
| Participants |
|
| Age, Continuous | Median | Full Range | years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Ethnicity (NIH/OMB) | Count of Participants | Participants |
|
| Race/Ethnicity, Customized | Count of Participants | Participants |
|
| Region of Enrollment | Count of Participants | Participants |
|
|
| Primary | MRI-derived R2* Values Using 1.5T UTE Technique | Hepatic iron content of the liver using MRI-derived 1.5T R2*-UTE measurement, with results in Hz. R2* is a measure obtained with MRI, i.e., MRI R2*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2* value low. T2* is the reciprocal of R2* (R2*= 1/T2*). So, if the signal drops fast, the T2* is low and the R2* is high. In this study, we are measuring the R2* value. The higher the R2*, the more iron in the liver tissue. We can compare the R2* value with that of a liver biopsy to then use the R2* value to tell us how much iron is in the liver without having to biopsy the liver. | Eligible iron-overloaded patients with both liver biopsy measurement and 1.5T R2*-UTE measurement. | Posted | Median | Full Range | Hz | Up to 30 days after MRI |
|
|
|
| Secondary | MRI-derived R2* Using 1.5T GRE Technique | MRI-derived R2* Using 1.5T GRE Technique in Hz. R2* is a measure obtained with MRI, i.e., MRI R2*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2* value low. T2* is the reciprocal of R2* (R2*= 1/T2*). So, if the signal drops fast, the T2* is low and the R2* is high. In this study, we are measuring the R2* value. The higher the R2*, the more iron in the liver tissue. We can compare the R2* value with that of a liver biopsy to then use the R2* value to tell us how much iron is in the liver without having to biopsy the liver. | Iron-overloaded patients had 1.5T R2*-GRE measurements. | Posted | Median | Full Range | Hz | Up to 30 days after MRI |
|
|
|
| Secondary | MRI Derived R2* Using 1.5T UTE Technique | MRI-derived R2* value using 1.5T R2*-UTE in Hz. R2* is a measure obtained with MRI, i.e., MRI R2*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2* value low. T2* is the reciprocal of R2* (R2*= 1/T2*). So, if the signal drops fast, the T2* is low and the R2* is high. In this study, we are measuring the R2* value. The higher the R2*, the more iron in the liver tissue. We can compare the R2* value with that of a liver biopsy to then use the R2* value to tell us how much iron is in the liver without having to biopsy the liver. | Iron-overloaded patients had 1.5T R2*-UTE-measurement. | Posted | Median | Full Range | HZ | up to 30 days after MRI |
|
|
|
| Secondary | R2* Using 1.5T UTE Technique for Patients With Serum Iron and Transferrin Saturation Measurements | MRI-derived R2* value using 1.5T R2*-UTE in Hz for patients who have had serum iron and transferrin saturation measurements. R2* is a measure obtained with MRI, i.e., MRI R2*. It is measured in hertz (Hz). In lay terms, the MRI machine picks up a signal back from the tissue during the process of scanning the tissues. With every "picture taken", this signal is strong in the beginning and then wanes off. R2* reflects how fast the signal wanes off. If there is too much iron in the tissue, the signal disappears faster, making the T2* value low. T2* is the reciprocal of R2* (R2*= 1/T2*). So, if the signal drops fast, the T2* is low and the R2* is high. In this study, we are measuring the R2* value. The higher the R2*, the more iron in the liver tissue. We can compare the R2* value with that of a liver biopsy to then use the R2* value to tell us how much iron is in the liver without having to biopsy the liver. | 1.5T R2*-UTE from eligible patients who had 1.5T R2*-UTE, serum iron, and transferrin saturation measurements. | Posted | Median | Full Range | Hz | Up to 30 days after MRI |
|
|
|
| Secondary | Serum Iron Measurements Compared With 1.5T R2* UTE | Serum iron measurements from eligible patients had 1.5T R2*-UTE and serum iron and transferrin saturation measurements. | Iron-overloaded patients had 1.5T R2*-UTE and serum iron and transferrin saturation measurements. | Posted | Median | Full Range | ug/dL | Up to 30 days after MRI |
|
|
|
| Secondary | Transferrin Saturation Measurements | Iron Transferrin Saturation in % measurements Transferrin Saturation measurements from eligible patients had 1.5T R2*-UTE and serum iron and transferrin saturation measurements. | Iron-overloaded patients had 1.5T R2*-UTE and serum iron and transferrin saturation measurements. | Posted | Median | Full Range | percentage | Up to 30 days after MRI |
|
|
|
| 1 |
| 142 |
| 1 |
| 142 |
| 2 |
| 142 |
| abdominal pain | Gastrointestinal disorders | Systematic Assessment |
|
Not provided
Not provided
Not provided
| D000743 | Anemia, Hemolytic |
| D000740 | Anemia |
| D006402 | Hematologic Diseases |
| D006425 | Hemic and Lymphatic Diseases |
| D006453 | Hemoglobinopathies |
| D030342 | Genetic Diseases, Inborn |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |
| D008664 | Metal Metabolism, Inborn Errors |
| D008661 | Metabolism, Inborn Errors |