Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The investigators assessed if use of AgION-impregnated umbilical catheters can decrease the occurrence of catheter-related bloodstream infections (CRBSI) in preterm infants.
Recently, a silver zeolite-impregnated catheter has been commercialized. This material, namely the patented silver compound AgIONâ„¢, releases antimicrobially active silver ions which may help prevent catheter-related bloodstream infections CRBSIs which are frequent in preterm infant.
The investigators hypothesized that the use of AgION-impregnated umbilical catheters could decrease the occurrence of CRBSIs in preterm infants. To assess this hypothesis the investigators carried out a randomized controlled study in which preterm infants needing an umbilical vein catheter would received either an AgION catheter or a traditional non-impregnated polyurethane catheter.
Infants with gestational age < 30 weeks were randomized to receive an AgION- impregnated or non-impregnated polyurethane umbilical venous catheter (UVC) by opening sealed opaque envelopes. The primary end point was the incidence of CRBSIs during the time the UVC was in place.
The investigators studied 86 infants, 41 of whom received the AgION catheter and 45 the non-impregnated catheter. During umbilical venous catheterization 2% of infants in the AgION group developed CRBSI in comparison with 22% of infants in the control group (p=0.005). The incidence density of CRBSIs during the study period was lower in infants who received AgION catheters compared to the control group (2.1/1000 catheter days versus 25.8/1000 catheter days; p<0.001). The occurrence of UVC colonization was similar in both groups. The Kaplan-Meier estimates of the cumulative likelihood of being free of a CRBSI at each day of UVC placement demonstrate the statistically significant (p=0.004) protective effect of AgION impregnated catheters. Moreover, infants in the AgION group had shorter hospital stay (p=0.04), and a lower case fatality rate due to BSI (p=0.01) than infants in the control group.
AgION catheters were well tolerated and none of patients showed signs attributable to silver toxicity.
Multivariate analysis demonstrated that non-impregnated catheter use (OR 12.5, 95% C.l. 2.06-75.9) and catheter placement for more than 7 days (OR 5.1, 95% C.l. 1.13-23.6) increased the risk of developing a CRBSI in our population.
Conclusions. The AgION-impregnated UVCs were effective in decreasing the development of CRBSIs in preterm infants compared to non-impregnated polyurethane UVCs.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| AgION catheter | Experimental | Patients in this arm received an AgION impregnated catheter (4.0-5.0 F Lifecath PICC ExpertTM, Vygon, Ecouen, France). |
|
| Non-impregnated polyurethane catheter | Active Comparator | Patients in this arm received a non-impregnated polyurethane umbilical catheter (3.5-5.0 F ArgyleTM, Kendall, Tullamore, Iceland) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Umbilical catheterization (AgION ) | Device | Infants received a AgION impregnated catheter (4.0-5.0 F Lifecath PICC ExpertTM, Vygon, Ecouen, France). |
|
| Measure | Description | Time Frame |
|---|---|---|
| Incidence of CRBSIs | We evaluated the incidence of CRBSIs (definite plus probable) during the time the UVC was in place. | Infants were followed for the duration the AgION umbilical venous catheter (UVC) was in place, an expected average of 10 days |
| Measure | Description | Time Frame |
|---|---|---|
| Infection density | Number of infections/1000 catheter days, likelihood of freedom from CRIBSIS, and signs of catheter intolerance and possible adverse effects from silver ion toxicity were evaluated for the duration of umbilical venous catheterization; occurrence of BPD, IVH, PVL, ROP, and NEC, length of stay in hospital, case fatality rate for infants with CRBSI, and death were evaluated at discharge. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Carlo Dani, MD | Department of Surgical and Medical Critical Care, Section of Neonatology, University of Florence | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Careggi Univesity Hospital | Florence | Italy | 50141 | Italy |
Not provided
| ID | Term |
|---|---|
| D055499 | Catheter-Related Infections |
| ID | Term |
|---|---|
| D007239 | Infections |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Umbilical catheterization (ArgyleTM) | Device | Infants received a polyurethane non-impregnated catheter (3.5-5.0 F ArgyleTM, Kendall, Tullamore, Iceland) |
|
| Infants were followed for the duration the AgION umbilical venous catheter (UVC) was in place, an expected average of 10 days |
| Likelihood of freedom from CRIBSIs | Likelihood of freedom from CRIBSIS for the duration of umbilical venous catheterization | Infants were followed for the duration the AgION umbilical venous catheter (UVC) was in place, an expected average of 10 days |
| AgION catheters tolerability | Signs of local intolerance, such as skin infection, were recorded. We also evaluated possible adverse effects from silver ion toxicity, such as the occurrence of argyria (blue-grey discoloration of the skin) or hepatic damage (i.e.: increase in AST/ALT enzymes). | Infants were followed for the duration the AgION umbilical venous catheter (UVC) was in place, an expected average of 10 days |
| Case fatality rate for infants with CRBSI | We evaluated the mortality caused by CRBSI in infants who received AgION-impregnated and non-impregnated groups. | Hospital stay duration, an expected average of 80 days |