Atrial fibrillation (AF) is the most common arrhythmia affecting the Canadian population. AF is associated with increased risk of stroke,HF, and even mortality. AF can cause debilitating symptoms, adversely affect patient's (pt's) quality of life and functional status. Hence a strategy of sinus rhythm (SR) may be pursued over a strategy of allowing AF to persist. Percutaneous catheter ablation is an effective alternative to antiarrhythmic drugs (AAD) for maintaining SR. The success rate of PV isolation off AAD is about 80-90% in pt's with PAF, but repeat procedures are required in up to 40% of pt's. After one ablation, the success rate may only be 50-70% off drugs.Current standard ablation procedures for PV antral isolation employ mapping systems which reconstructions of the LA and PV anatomy are created. Visualization may be supplemented by integration of CT/ MRI images and/or intracardiac echocardiography. Robotic navigation has been employed to assist in ablation. Based on single point unipolar radiofrequency (RF) ablation catheter where lesions are created point-by-point around the PVs to obtain electrical isolation.This results in lengthy complex, costly procedures,often more than 4 hours, which requires high degree of operator skill.Creation of contiguous, transmural lesions is challenging with standard single-point RF. A novel multipolar catheter ablation system has been evaluated for achieving PV isolation (PVAC catheter, Medtronic Inc.) An over-the-wire circular mapping/ablation catheter can be advanced into the PV antrum, and multiple lesions around the circumference of the catheter can be delivered simultaneously using duty-cycled unipolar and bipolar RF energy. Early reports, the system can achieve complete PV isolation with reduced fluoroscopy and procedural times using lower powers to achieve more reliable lesion sets.Long-term efficacy also seems comparable to standard RF ablation.This novel technology has potential to broaden the application of AF ablation, making procedures less time-consuming, less complex without compromising procedural efficacy. Published data PVAC technology outcomes are limited to studies with small sample sizes of 12-102 pt's. Data has been restricted to a small number of European centers performing moderate numbers of PVAC procedures. There is no prospective, multicenter data. Little is known about the efficiency of PVAC procedures, allowing for an assessment of cost-effectiveness in using this technology.
This is a multicenter, open label, prospective, cohort study. Patients undergoing ablation with PVAC technology in up to 15 centers across Canada will be enrolled, ablated, and followed for one year post-ablation. Both primary and secondary objectives of the study will be determined from this cohort of patients. Comparisons to the traditional ablation methods will be made by collecting data from a prospective group of control subjects who are undergoing AF ablation with traditional ablation technology at the same centers by the same operators. Control patients will be enrolled in a 1:2 ratio compared to the PVAC cohort. While the final ratio of control to PVAC patients must be 1:2 by study end for each operator, the ratio may vary while the study is conducted to allow some flexibility in patient recruitment. However, the absolute difference between [# of PVAC patients] and 2x[# control patients] should not exceed 5 at any given time for any operator in any study center
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Control | Active Comparator | Radiofrequency Ablation Procedure. Subjects who are undergoing AF ablation with traditional ablation technology at the same centers by the same operators. Control patients will be enrolled in a 1:2 ratio compared to the PVAC cohort. Intervention is the use of Radiofrequency Ablation. |
|
| PVAC Ablation Procedure | Experimental | Intervention is the use of PVAC technology. The PVAC is deployed in the left atrium over a 0.032-inch guidewire inside the PV and advanced until it is wedged within the antrum proximal to the ostium. Energy is delivered through selected electrode pairs with local potentials as well as adjacent electrode pairs, allowing bipolar current to flow to the target electrode(s) from both sides. Each application lasts for 60 seconds. When the temperature does not rise above 50°C within 15 seconds, the application should be discontinued to improve position. The PVAC may be manipulated within the antrum to ablate in a pattern of overlapping circular lesions. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Radiofrequency Ablation Procedure | Device | Application of radiofrequency energy will be delivered during PV antral isolation procedure and should be performed with a standard, open irrigated ablation catheter and a mapping system as the investigator would perform the procedure normally. |
| Measure | Description | Time Frame |
|---|---|---|
| Procedure Duration and Fluoroscopy time | Length of procedure measure in hours/minutes and use of fluoroscopy measured in minutes | At the time of the initial ablation procedure and repeat ablations. |
| Measure | Description | Time Frame |
|---|---|---|
| Incidence of emergency room visits, hospitalizations and urgent clinic visits. | Incidence of emergency room visits, hospitalizations and urgent clinic visits one year prior to ablation and 3, 6, 9, and 12 months post ablation. | 1 year follow-up post ablation |
| Quality of Life measurements (CCS-SAF, AFEQT and SF-12) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Atul Verma, MD | Newmarket Electrophysiology Research Group | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hamilton Health Sciences | Hamilton | Ontario | Canada | |||
| London Health Sciences Center |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32531030 | Derived | Essebag V, Azizi Z, Alipour P, Khaykin Y, Leong-Sit P, Sarrazin JF, Sturmer M, Morillo C, Terricabras M, Amit G, Roux JF, Patterson S, Verma A. Relationship between quality of life and burden of recurrent atrial fibrillation following ablation: CAPCOST multicentre cohort study. Europace. 2020 Jul 1;22(7):1017-1025. doi: 10.1093/europace/euaa066. |
Not provided
Not provided
to be determined
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| PVAC Ablation Procedure | Device | Application of radiofrequency energy with the Pulmonary Vein Ablation Catheter(PVAC)to eliminate potentials arising from the pulmonary veins. |
|
|
Quality of Life measurements (CCS-SAF , AFEQT and SF-12) questionnaires at baseline, 3, 6 , 9 and 12 months. |
| 1 year post ablation |
| Total ablation procedure costs. | calculation of procedural costs | 1 year post ablation |
| London |
| Ontario |
| N6A 5A5 |
| Canada |
| Southlake Regional Health Centre | Newmarket | Ontario | L3Y 2P9 | Canada |
| McGill University Health Centre | Montreal | Quebec | H3G 1A4 | Canada |
| Hôpital Sacré-Coeur de Montréal | Montreal | Quebec | H4J 1C5 | Canada |
| Institut universitaire de cardiologie et de pneumologie de Québec | Québec | Quebec | G1V 4G5 | Canada |
| ID | Term |
|---|---|
| D001281 | Atrial Fibrillation |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided