The study investigates if applying a special ventilatory strategy during anesthesia for laparoscopic gastric by pass, produces less atelectasis and better oxygenation in spite of using 100 % oxygen during pre oxygenation and induction of anesthesia. The study investigates oxygenation with blood gas samples but also with a new method that might give more information without the use of blood gas samples.
Primary: Oxygenation in patients with morbid obesity improves if preoxygenation, induction and maintenance of anesthesia is performed with either a continuous positive airway pressure (CPAP) or a positive end expiratory pressure (PEEP), respectively, of 10 cm H2O, in comparison to a technique without CPAP but with a PEEP of 10 cm H2O.
Secondary: The improved oxygenation during anesthesia can be prolonged inte the postoperative period if emergence from anesthesia is performed without high levels of oxygen.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Start O2 100% and CPAP 10, end O2 100%. | Experimental | This arm describes some aspects of ventilation during anesthesia for laparoscopic gastric bypass. Pre-oxygenation is with an inspiratory oxygen fraction(FIO2) of 1.0, supplied by a continuous positive airway pressure of 10 centimeters of water(cmH2O), during anesthesia a positive end-expiratory pressure of 10 cmH2O is used and during emergence from anesthesia a FIO2 of 1.0 is used. The intervention associated with this arm is labeled CPAP and 100% oxygen. |
|
| Start O2 100% and CPAP 10, end O2 31%. | Experimental | This arm describes some aspects of ventilation during anesthesia for laparoscopic gastric bypass. Pre-oxygenation is with a FIO2 of 1.0, supplied by a continuous positive airway pressure of 10 cmH2O, during anesthesia a positive end-expiratory pressure of 10 cmH2O is used and during emergence from anesthesia a FIO2 of 0.3 is used. The intervention associated with this arm is labeled CPAP and 31% oxygen. |
|
| Start O2 100% and CPAP 0, end O2 100%. | Experimental | This arm describes some aspects of ventilation during anesthesia for laparoscopic gastric bypass. Pre-oxygenation is with a FIO2 of 1.0, without a continuous positive airway pressure, during anesthesia a positive end-expiratory pressure of 10 cmH2O is used and during emergence from anesthesia a FIO2 of 1.0 is used. The intervention associated with this arm is labeled No CPAP and 100% oxygen. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| CPAP and 100% oxygen | Procedure | During pre oxygenation and induction of anesthesia 100 % oxygen is used with a continuous positive airway pressure of 10 cmH2O, during maintenance of anesthesia a positive endexpiratory pressure of 10 cm H20 is used with controlled volume ventilation aiming at an end tidal carbon dioxide (CO2) level of 5 %. During emergence from anesthesia 100 % oxygen is used. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in peripheral O2 saturation(SpO2)during and 1 hour after anesthesia in comparison to awake before anesthesia. | During anesthesia SpO2 is measured at three different levels of oxygen; 21, 26 and 31 % respectively as long as SpO2 does not go lower than 87 % and compared to SpO2 immediately before anesthesia. SpO2 breathing air one hour after anesthesia is compared to SpO2 before anesthesia. | Change in SpO2 from 5 min before start of anesthesia, to 5 min after intubation, 5 min before extubation and 1 hour after extubation. |
| Measure | Description | Time Frame |
|---|---|---|
| Arterial blood gas values for saturation (SaO2) | During anesthesia SaO2 is measured at three different levels of oxygen; 21, 26 and 31 % respectively as long as SpO2 (sic! does not go lower than 87 % and compared to SaO2 immediately before anesthesia. SaO2 breathing air one hour after anesthesia is compared to SaO2 before anesthesia. | 5 min before anesthesia, 5 min after intubation, 5 min before extubation and 1 hour after anesthesia. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Göran Hedenstierna, Prof. | Uppsala University Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Operationskliniken, Västmanlands sjukhus Västerås | Västerås | 721 89 | Sweden |
Not provided
| ID | Term |
|---|---|
| D009767 | Obesity, Morbid |
| ID | Term |
|---|---|
| D009765 | Obesity |
| D050177 | Overweight |
| D044343 | Overnutrition |
| D009748 | Nutrition Disorders |
Not provided
Not provided
| ID | Term |
|---|---|
| D010100 | Oxygen |
| C077194 | AIEOP acute lymphoblastic leukemia protocol |
| ID | Term |
|---|---|
| D018011 | Chalcogens |
| D004602 | Elements |
| D007287 | Inorganic Chemicals |
| D005740 | Gases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| CPAP and 31% oxygen | Procedure | During pre oxygenation and induction of anesthesia 100 % oxygen is used with a continuous positive airway pressure of 10 cm H2O, during maintenance of anesthesia a positive endexpiratory pressure of 10 cm H20 is used with controlled volume ventilation aiming at an end tidal CO2 level of 5 %. During emergence from anesthesia 31 % inspiratory oxygen or the inspiratory oxygen level needed to achieve a SpO2 of at least 96 % (if 31 % oxygen is not enough), is used. |
|
|
| No CPAP and 100% oxygen | Procedure | This intervention follows a standard protocol without the use CPAP during induction of anesthesia. |
|
|
| Arterial oxygen tension (PaO2) | During anesthesia PaO2 is measured at three different levels of oxygen; 21, 26 and 31 % respectively as long as SpO2 (sic) does not go lower than 87 % and compared to PaO2 immediately before anesthesia. PaO2 breathing air one hour after anesthesia is compared to PaO2 before anesthesia. | 5 min before start of anesthesia, 5 min after intubation, 5 min before extubation and 1 hour after extubation. |
| D009750 |
| Nutritional and Metabolic Diseases |
| D001835 | Body Weight |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |