Not provided
Not provided
Not provided
Not provided
Not provided
Lack of sufficient enrollment
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| DJO Incorporated | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to evaluate the use and efficacy of the 3DKnee™ System using Vitamin E UHMWPE tibial inserts for total knee replacement surgery.
Total knee replacement surgery is widely accepted as effective treatment for degenerative joint disease (DJD), osteoarthritis and rheumatoid arthritis. Relief of patient pain and return of mobility are the primary goals that can be accomplished by this surgery. Currently available prosthetic designs accomplish these goals and the surgery has been defined as one of the most successful operations available to improve the quality of life for patients with DJD. This study will evaluate subjects who are candidates for a total knee replacement and meet the indications for use criteria for the 3DKnee™ System with vitamin E UHMWPE tibial inserts (VE).
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 3DKnee™ with e-plus Insert | Subjects who meet the indications for use criteria for the 3DKnee™ System with vitamin E UHMWPE tibial inserts (VE) and who are candidates for a primary knee arthroplasty. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 3DKnee™ System with Vitamin E UHMWPE Tibial Inserts | Device | This device is part of a total knee replacement system utilized in treating patients who are candidates for primary cemented total knee arthroplasty or revision arthroplasty where bone loss is minimal and the collateral ligaments are intact. It is intended to aid the surgeon in relieving the patient of knee pain and restoring knee joint function. |
| Measure | Description | Time Frame |
|---|---|---|
| Efficacy of the Vitamin E UHMWPE as part of the total knee system, measured by Knee Society Score Evaluation and total number of radiologic failures of the device. | The (American) Knee Society Score has both an objective and a functional component. The objective score takes into account pain, flexion, stability, alignment, extension lag and flexion contracture. Overall success will be defined as a KSS score ≥ 80 at two years. Radiolucencies have been defined as two types, with one type being more common than the other. In the case of physiologic radiolucency, which is the most common type of radiolucency seen, there is a narrow line present that is well-defined around the prosthesis. This line is surrounded by a radio-dense line and tends to consolidate (disappear) within the first year. The second type of radiolucency, the pathologic radiolucency, is rarer and is associated with loosening and infection. It is a progressive, poorly defined radiolucency that is more than 2 mm thick and without a radiolucent line. | 2 year |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Knee Society Score from pre-surgery to 10 years | The Knee Society Score includes a knee rating and function score. This evaluation covers the knee rating score with three main parameters of pain, stability and range of motion and that flexion contracture, extension lag and misalignment should be dealt with as deductions. Thus, 100 points will be obtained by a well-aligned knee with no pain, 125 degrees of motion, and negligible anteroposterior and mediolateral instability. 50 points are allotted for pain, 25 for stability, and 25 for range of motion. Grading for KS Score: Excellent (90-100), Good (80-90), Fair (70-79) and Poor (<70). |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Subjects must be diagnosed with either osteoarthritis or traumatic arthritis and be candidates for a primary total knee arthroplasty. They must also meet the indications for use for the 3DKnee system with the vitamin E tibial insert.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Orthopaedic Surgery Specialists | Burbank | California | 91505 | United States | ||
| Orthopedic Specialists of North County |
Not provided
| ID | Term |
|---|---|
| D007592 | Joint Diseases |
| D010003 | Osteoarthritis |
| ID | Term |
|---|---|
| D009140 | Musculoskeletal Diseases |
| D001168 | Arthritis |
| D012216 | Rheumatic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| 10 year |
| Change in WOMAC Osteoarthritis Index from pre-surgery to 10 years | The Western Ontario McMaster Arthritis Index is a set of standardized questionnaires used by health professionals to evaluate the condition of patients with osteoarthritis of the knee and hip. It can be self-administered. It assesses the pain, joint stiffness, physical, social & emotional function of a person with osteoarthritis in determining the overall level of disability. | 10 year |
| Change in Oxford Knee Score from pre-surgery to 10 years | The Oxford Knee Score (OKS) is a patient-based outcomes measure consisting of 12 questions that is sensitive, simple and validated. It is based on a maximum score of 48. | 10 year |
| Change in response to Quality of Life questions from pre-surgery to 6 months and each year thereafter through 10 years | 10 years |
| 6. Change in pain from pre-surgery to 6 months and each year thereafter through 10 years | 10 years |
| Oceanside |
| California |
| 92056 |
| United States |
| Institute for Orthopaedic Surgery and Sports Medicine | Fort Myers | Florida | 33919 | United States |
| St. Peter's Bone & Joint Surgery | City of Saint Peters | Missouri | 63376 | United States |
| New Mexico Orthopedics | Albuquerque | New Mexico | 87106 | United States |
| Texas Institute for Hip and Knee Surgery | Austin | Texas | 78751 | United States |