The purpose of this study is to investigate the short to mid term efficacy and safety of a newly-developed branched stent graft in patients who had complex aortic lesions, such as ascending aortic/arch aneurysm, pseudo-aneurysm, Stanford Type A dissection, retrograde Stanford Type B dissection, dissection with primary tear located in the aortic arch, et al.
Aneurysms and dissection involving the ascending aorta and aortic arch have historically been treated with open surgical techniques, requiring cardiopulmonary bypass and deep hypothermic circulatory arrest (DHCA). Despite increasing experience and refinement of these procedures, there remains a substantial rate of morality and morbidity. Total endovascular aortic arch and ascending aorta repair is one of the ultimate solutions of these diseases. However, this approach requires extensive technique and new device development. The goal of total endoluminal stent grafting is to re-construct the ascending aorta and aortic arch to cover the primary entry tear of the dissection and to remodel the aorta.Recently, branch and fenestrated stent-grafts has been developed to treat complex ascending and aortic arch disease, which was previously considered to be contraindicated for endovascular repair. This study aims to investigate the short to mid term efficacy and safety of a newly-developed branched stent graft in patients who had complex aortic lesions, such as ascending aortic/arch aneurysm, pseudo-aneurysm, Stanford Type A dissection, retrograde Stanford Type B dissection, dissection with primary tear located in the aortic arch, et al.
Primary outcome measure is all-cause mortality. Secondary outcome variables include conversion to stent and/or surgery, induced thrombosis of the false lumen, cardiovascular morbidity, aortic expansion (>5 mm/y of maximum diameter including true and false lumina), quality of life, and length of intensive care unit and hospital stay. The study designs to enroll 50 patients to be monitored for 24 months.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Endovascular | Experimental | Total endovascular arch reconstruction |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ankura Branched/Fenestrated Stent Graft | Device | Ankura Branched/Fenestrated Stent Graft(Lifetech Scientific Co.,LTD.,Shenzhen, China) |
|
| Measure | Description | Time Frame |
|---|---|---|
| cumulative MACE (including death, rupture, paraplegia, aneurysm formation) | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Endoleak | Endoleak of all types | 12 months |
| Stent-graft migration/kinking | Stent-graft migration, stenosis, kinking and other conditions requiring re-intervention |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Jian Yang, MD,PhD | Contact | 86-13892828016 | yangjian1212@hotmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Jian Yang, MD,PhD | Department of Cardiovascular Surgery of Xijing Hospital, Fourth Military Medical University | Principal Investigator |
| Dinghua Yi, M.D., PhD. | Department of Cardiovascular Surgery of Xijing Hospital, Fourth Military Medical University |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Cardiovascular Surgery of Xijing Hospital, Fourth Military Medical University | Recruiting | Xi'an | Shaanxi | 710032 | China |
Not provided
| ID | Term |
|---|---|
| D000784 | Aortic Dissection |
| D001014 | Aortic Aneurysm |
| D001018 | Aortic Diseases |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| ID | Term |
|---|---|
| D000094665 | Dissection, Blood Vessel |
| D000783 | Aneurysm |
| D000094683 | Acute Aortic Syndrome |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 12 months |
| cumulative cerebrovascular events | cumulative cerebrovascular events | 12 months |