Percutaneous coronary intervention (PCI) with stenting may induce endothelial damage/dysfunction and inflammatory reactions, which in turn delay healing and endothelialization and may lead to restenosis and atherosclerosis within the stented segments. Drugs and polymers are considered the protagonists of these pathophysiologic processes whereas the role of stent platforms remains poorly defined.It remains unknown, conversely, if stent platforms affect the extent of post-PCI endothelial damage and inflammation.
Percutaneous coronary intervention (PCI) with stenting may induce endothelial damage/dysfunction and inflammatory reactions, which in turn delay healing and endothelialization and may lead to restenosis and atherosclerosis within the stented segments.
Drugs and polymers are considered the protagonists of these pathophysiologic processes whereas the role of stent platforms remains poorly defined.
Due to advances in stent technology, stent platforms have evolved from the cobalt-chromium (CoCr) to the platinum-chromium (PtCr) stent series. At present, the PROMUS Element stent (which uses the PtCr platform) employs an identical polymer, drug, drug formulation and dose density to the CoCr XIENCE V stent.
The PLATINUM WH trial is the only randomized trial comparing the PROMUS Element stent with the XIENCE V stent in a total of 1,530 patients. The study met its primary end-point demonstrating that the PROMUS Element stent is non-inferior to the XIENCE V stent. The 12-month rare of target lesion failure was 3.4% in the PROMUS Element stent and 2.9% in the XIENCE V stent.
Pre-clinical animal studies, however, suggest that the PtCr platform might have important advantages over the CrCo platform, as improved vascular compatibility and early and late healing for PtCr devices compared with CoCr stents have been demonstrated.
In a rabbit denudation model, it was shown that at 14 days the luminal surface area is incompletely endothelialised with the CrCo stents but nearly complete for the PtCr stents. Similarly, another experimental study has shown that overall strut coverage, including endothelial cell coverage plus non-endothelial cell coverage (focal platelet and fibrin aggregates inter-mixed with red blood cells and inflammatory cells), is significantly lower at 14 days with the CoCr stent than with the PtCr OMEGA stent. Additionally, a recent investigation has shown that the thinner-strut PtCr stent is associated with reduced fibrin deposition and more rapid fibrin clearance in porcine coronary arteries compared with CrCo stent, thus suggesting that the PtCr stent platform may induce less injury compared with previous-generation platforms.
The primary objective of this study is to perform a randomized comparison of the biohumoral effects of platinum chromium everolimus-eluting stent (PtCr EES) vs. cobalt chromium everolimus-eluting stent (CoCr EES), i.e. stents with different platforms but identical drug and polymer.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| platinum chromium EES | Active Comparator | Patients undergoing PCI with stenting will have implantation of platinum chromium everolimus-eluting stents |
|
| cobalt chromium everolimus-eluting stent | Active Comparator | Patients undergoing PCI with stenting will have implantation of cobalt chromium everolimus-eluting stents |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| platinum chromium everolimus-eluting stent | Device | An everolimus-eluting stent with a platinum chromium platform |
|
| Measure | Description | Time Frame |
|---|---|---|
| Post-PCI changes in markers of endothelial damage | Changes 24 hours after PCI in the following indexes of endothelial damage:
| Baseline and 24 hours after PCI |
| Post-PCI changes in markers of inflammation | Changes 24 hours after PCI in the following inflammatory markers:
| Baseline and 24 hours after PCI |
| Measure | Description | Time Frame |
|---|---|---|
| 12-month rate of MACE | 12-months incidence of major adverse cardiac events (MACE-death, myocardial infarction, target vessel revascularization) | Up to 12 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
• Women of child bearing potential patients must demonstrate a negative pregnancy test performed within 24 hours before CT
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Francesco Pelliccia, MD, PhD | Contact | +393483392006 | f.pelliccia@mclink.it | |
| Cesare Greco, MD | Contact | +39 335 8381320 | cesare.greco@uniroma1.it |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University La Sapienza | Rome | 00166 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 22360944 | Derived | Pelliccia F, Del Prete G, Del Prete A, Greco C, Gaudio C. Effects of percutaneous coronary intervention and stenting with different drug-eluting coatings and platforms on endothelial damage and inflammation. Int J Cardiol. 2012 Apr 19;156(2):242-3. doi: 10.1016/j.ijcard.2012.01.059. Epub 2012 Feb 22. No abstract available. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| cobalt chromium everolimus-eluting stent | Device | An everolimus-eluting stent with cobalt chromium platform |
|
|
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |