It has been shown that compliance with brace wear can significantly improve the treatment outcome of idiopathic clubfoot deformities. Noncompliance rates have been estimated to be around 30-41% with initial orthosis wear after successful treatment with serial castings. These studies have depended on family logs and not objective data. With the development of a monitoring device, this study hopes to examine: (1) actual patient compliance, (2) comparisons of actual wear time and assumed wear time and (3) the relationship of patient wear with clinical outcomes.
Hypothesis:
Actual patient compliance in foot abduction orthoses (FAO) wear is less than self-reported compliance and noncompliance is correlated to future surgeries.
It is necessary that treatment teams avoid making any assumptions about patient compliance. This study will objectively measure brace wear-rate in patients with clubfoot that have already been prescribed a foot ankle orthosis. The use of a monitoring device will be able to give objective data on actual patient compliance with brace wear. It is hypothesized that objective compliance data will allow physicians to better assess the patient's therapy progress and outcome, troubleshoot problems or issues associated with barriers to brace wear, and better educate families confronted with having a child with clubfoot. Long term goals will then attempt to determine whether certain brace designs can increase wear time thus decreasing the rate of clubfoot recurrence.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Functioning Pressure Sensor Group | This group will have a functioning pressure sensor placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. | ||
| Non-Functioning Pressure Sensor Group | This group will have a non-functioning pressure sensor (a placebo) placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. | ||
| No Sensor Group | This group will not have a pressure sensor placed on the foot ankle orthosis. |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Wear Rate Percentage (Number of Hours Per Day Brace Was Worn Out of the Recommended 24 Hours) | Number of hours per day in brace will be measured by pressure sensor at the end of month 1, month 2 and month 3. Parent report of brace wear will also be documented at each of these timepoints. Wear rate percentage will be calculated by dividing the number of hours of brace wear (either actual as measured by the sensor or reported by parent diary) by the recommended 24 hours. | 3 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
All clubfoot patients scheduled to be placed in a foot ankle orthosis (FAO)
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Todd A Milbrandt, MD | Shriners Hospital for Children | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Shriners Hospital for Children | Lexington | Kentucky | 40502 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17012432 | Background | Changulani M, Garg NK, Rajagopal TS, Bass A, Nayagam SN, Sampath J, Bruce CE. Treatment of idiopathic club foot using the Ponseti method. Initial experience. J Bone Joint Surg Br. 2006 Oct;88(10):1385-7. doi: 10.1302/0301-620X.88B10.17578. | |
| 10934626 | Background | Dobbs MB, Morcuende JA, Gurnett CA, Ponseti IV. Treatment of idiopathic clubfoot: an historical review. Iowa Orthop J. 2000;20:59-64. |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Functioning Pressure Sensor Group | This group will have a functioning pressure sensor placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. |
| FG001 | Non-Functioning Pressure Sensor Group | This group will have a non-functioning pressure sensor (a placebo) placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. |
| FG002 | No Sensor Group | This group will not have a pressure sensor placed on the foot ankle orthosis. |
| Title | Milestones | Reasons Not Completed | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Number analyzed in each group
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Functioning Pressure Sensor Group | This group will have a functioning pressure sensor placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. |
| BG001 | Non-Functioning Pressure Sensor Group |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Wear Rate Percentage (Number of Hours Per Day Brace Was Worn Out of the Recommended 24 Hours) | Number of hours per day in brace will be measured by pressure sensor at the end of month 1, month 2 and month 3. Parent report of brace wear will also be documented at each of these timepoints. Wear rate percentage will be calculated by dividing the number of hours of brace wear (either actual as measured by the sensor or reported by parent diary) by the recommended 24 hours. | Posted | Mean | Full Range | percentage of time worn | 3 months |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Functioning Pressure Sensor Group | This group will have a functioning pressure sensor placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. |
Not provided
Not provided
As shown in the monthly completion numbers, most families complied during the first month of treatment. After the first month, not only did the wear rates drop significantly, but also the number of subjects reporting sensor and diary data.
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Dr. Todd Milbrandt | Shriners Hospital for Children | 859-266-2101 | tmilbrandt@shrinenet.org |
Not provided
| ID | Term |
|---|---|
| D003025 | Clubfoot |
| D010349 | Patient Compliance |
| ID | Term |
|---|---|
| D000070558 | Talipes |
| D005531 | Foot Deformities, Acquired |
| D005530 | Foot Deformities |
| D009140 | Musculoskeletal Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| 17332096 | Background | Haft GF, Walker CG, Crawford HA. Early clubfoot recurrence after use of the Ponseti method in a New Zealand population. J Bone Joint Surg Am. 2007 Mar;89(3):487-93. doi: 10.2106/JBJS.F.00169. |
| 14711941 | Background | Dobbs MB, Rudzki JR, Purcell DB, Walton T, Porter KR, Gurnett CA. Factors predictive of outcome after use of the Ponseti method for the treatment of idiopathic clubfeet. J Bone Joint Surg Am. 2004 Jan;86(1):22-7. doi: 10.2106/00004623-200401000-00005. |
| 15718907 | Background | Thacker MM, Scher DM, Sala DA, van Bosse HJ, Feldman DS, Lehman WB. Use of the foot abduction orthosis following Ponseti casts: is it essential? J Pediatr Orthop. 2005 Mar-Apr;25(2):225-8. doi: 10.1097/01.bpo.0000150814.56790.f9. |
This group will have a non-functioning pressure sensor (a placebo) placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. |
| BG002 | No Sensor Group | This group will not have a pressure sensor placed on the foot ankle orthosis. |
| BG003 | Total | Total of all reporting groups |
| Participants |
|
| Sex: Female, Male | Count of Participants | Participants |
|
This group will have a non-functioning pressure sensor (a placebo) placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. |
| OG002 | No Sensor Group | This group will not have a pressure sensor placed on the foot ankle orthosis. |
|
|
| 0 |
| 21 |
| 0 |
| 21 |
| EG001 | Non-Functioning Pressure Sensor Group | This group will have a non-functioning pressure sensor (a placebo) placed on the foot ankle orthosis. The group will be blinded as to whether or not the sensor is functioning. | 0 | 24 | 0 | 24 |
| EG002 | No Sensor Group | This group will not have a pressure sensor placed on the foot ankle orthosis. | 0 | 22 | 0 | 22 |
Not provided
Not provided
| D005532 |
| Foot Deformities, Congenital |
| D038061 | Lower Extremity Deformities, Congenital |
| D017880 | Limb Deformities, Congenital |
| D009139 | Musculoskeletal Abnormalities |
| D000013 | Congenital Abnormalities |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |
| D010342 | Patient Acceptance of Health Care |
| D000074822 | Treatment Adherence and Compliance |
| D015438 | Health Behavior |
| D001519 | Behavior |