O2C is a diagnostic device for non-invasive determination of oxygen supply in microcirculation of blood perfused tissues. The optical sensor is easy to handle and guarantees reproducible examinations of local oxygen supply of tissues in clinics as well as in research. The examinations are without any strain for your patient.
Determines by use of a glass fibre probe:
Blood Flow in Microcirculation Capillary-Venous Oxygen Saturation Blood Filling of Microvessels Blood Flow Velocity This device makes it possible to supervise the local oxygen supply of organs and tissue.
With it is possible to measure locally the amount of oxygen which is transported into the region of interest and to diagnose local oxygen consumption of an organ. O2C's novelty is monitoring the energetic metabolism of cells by measuring the oxygen uptake with an optical sensor probe. Pathological O2-supply, which can lead to angiogenesis or cell-death and subsequently to organ failure, now can be detected in an early state by use of the new sensor system.
One of these new developed sensors are used to place in rectal position during extracorporeal circulation to determine the microcirculation.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Extracorporeal circulation | all patients were measured by microcirculation device O2C |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Heart Lung machine | Procedure | measurement of microcirculation with O2C device |
|
| Measure | Description | Time Frame |
|---|---|---|
| Blood Flow in Microcirculation | 3 hours |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Cardiac surgery patients with ecc
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Goethe University | Frankfurt am Main | Hesse | 60590 | Germany |
Not provided
| ID | Term |
|---|---|
| D006355 | Heart-Lung Machine |
| ID | Term |
|---|---|
| D001187 | Artificial Organs |
| D013523 | Surgical Equipment |
| D004864 | Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided