Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Difficult to recruit eligible subjects
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study will assess the outcomes of using magnetic navigation to treat ventricular tachycardia (VT) or premature ventricular contractions (PVCs) that occur for unknown reasons and are not related to structural heart disease.
During conventional ventricular arrhythmia ablation procedures, simply contacting the cardiac wall can significantly alter the electrocardiogram. Induction of ventricular ectopy is important in determining the focus of the arrhythmogenic tissue during an electrophysiology (EP) procedure; however, instrumentation with stiff ablation catheters can temporarily eliminate VT during the mapping portion of the procedure making it difficult to track the arrhythmia prior to ablating the tissue responsible for its genesis. The catheters used with the Stereotaxis Magnetic Navigation System (MNS) are less stiff compared to manual catheters since no pull wires are required to deflect the distal tip. Large external magnets positioned on either side of the EP procedure table create a magnetic field within the patient's chest. These large magnets (in direct relationship to the magnetic field) can be manipulated using specialized software. The physician controls the distal tip of the catheter by using the software while remotely using a catheter advancing system (QuickCAS®, Stereotaxis, Inc, St. Louis, MO) to reach the desired location within the heart. The soft catheters may provide a unique quality to the electrophysiologist who may assist by providing accurate maps without temporarily eliminating the ventricular ectopy due to excessive mechanical forces applied to the cardiac tissue. This study will assess the physician's ability to appropriately map and ablate the ventricular substrate using remote magnetic technology. All devices are approved by FDA and no off-label use of the products is mandated within the protocol.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Treatment | Ablation of VT/PVCs using a magnetic RF ablation catheter |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| RF Ablation | Device | Ablation of arrhythmogenic ventricular tissue |
|
| Measure | Description | Time Frame |
|---|---|---|
| Change in 24-hour Holter Monitor (number of extra ventricular beats) | Use of the MNS in mapping and ablation of idiopathic VT will lead to a 75% reduction in the number of individual ventricular ectopic beats 6 months after the procedure. Extra ventricular beats will be counted using a 24-hour Holter monitor pre-procedure (obtained no more than 30 days prior to the procedure) compared to a 24-hour Holter monitor 6 months post-procedure. | Change from Holter Monitor Pre-procedure vs. 6-Months Post-procedure |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Patients will be diagnosed with any ventricular tachycardia or symptomatic PVCs of non-ischemic origin.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Raul Weiss, MD | Ohio State University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| The Ohio State University | Columbus | Ohio | 43210 | United States |
Not provided
| ID | Term |
|---|---|
| D017180 | Tachycardia, Ventricular |
| ID | Term |
|---|---|
| D013610 | Tachycardia |
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| D000075224 |
| Cardiac Conduction System Disease |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |