Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| ORTESE HCPA-1 | Other Grant/Funding Number | Ministerio da Saude/MS |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The aim of the study is, primarily, evaluate the safety of the use of the silicone stent HCPA-1 in patients with clinically significant tracheal and/or bronchial stenosis. Secondarily, this study aims to evaluate the efficacy of the use of the silicone stent HCPA-1 who are in the same conditions described above and also estimate the costs the use of these silicone stents involve.
It is allowed to include patients for whom it is indicated the combination of treatments (eg, electrocoagulation followed by stent placement) - full anticoagulation or severe disturbance of coagulation. (Includes: use of any anticoagulant, by oral, intravenous or subcutaneous administration with full intention of coagulation / therapy; coagulopathy with INR> 2.0 or aPTT [KTTP]> 1.5 times control or platelet count <50000). Note: The use of antiplatelet drugs (aspirin, clopidogrel, ticlopidine) is allowed.
- The HCPA-1 silicone stent is made of biocompatible silicone, medical grade, via injection process in the matrix using different densities of the same material for a set of prostheses with rigid and flexible variables; available in the following dimensions (diameter x length in mm): 9x30, 9x50, 11x30, 11x50, 13x30, 13x50, 14x30, 14x50, 16x50, 16x70, 18x50 and 18x70. Requires specific surgical (applicator) for insertion.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Stents | Other | All recruited patients will be receiving a stent during a rigid bronchoscopy procedure. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Rigid bronchoscopy | Procedure | The HCPA-1 silicone stent available in the following dimensions (diameter x length in mm): 9x30, 9x50, 11x30, 11x50, 13x30, 13x50, 14x30, 14x50, 16x50, 16x70, 18x50 and 18x70 will be inserted through rigid bronchoscopy in patients who presented the criteria to participate in the study. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of participants with adverse events as a measurement of Safety | three main adverse events will be followed:
| 1 year |
| Measure | Description | Time Frame |
|---|---|---|
| Improvement in Dyspnea using a Dyspnea score as a measurement of Efficacy | MMRC dyspnea score will be used to measure the improvement of the patient's respiratory condition | 1 year |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Rosane P Schlatter, Master | Contact | 555133597872 | rschlatter@hcpa.ufrgs.br |
| Name | Affiliation | Role |
|---|---|---|
| Amarilio V Macedo, Postdoc | Hospital de Clinicas de Porto Alegre | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital Universitario Getulio Vargas | Recruiting | Manaus | Amazonas | 69010130 | Brazil |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21149399 | Background | Saueressig MG, Sanches PR, Macedo Neto AV, Moreschi AH, Oliveira HG, Xavier RG. Novel silicone stent to treat tracheobronchial lesions: results of 35 patients. Asian Cardiovasc Thorac Ann. 2010 Dec;18(6):521-8. doi: 10.1177/0218492310388428. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D055089 | Tracheobronchomalacia |
| ID | Term |
|---|---|
| D002357 | Cartilage Diseases |
| D009140 | Musculoskeletal Diseases |
| D001982 | Bronchial Diseases |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D015607 | Stents |
| ID | Term |
|---|---|
| D019736 | Prostheses and Implants |
| D004864 | Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Hospital Universitario de Brasilia | Recruiting | Brasília | Federal District | 70840901 | Brazil |
|
| Hospital das Clínicas de Goiania | Recruiting | Goiânia | Goiás | 74605020 | Brazil |
|
| Hospital Universitario Antonio Pedro | Recruiting | Niterói | Rio de Janeiro | 24322380 | Brazil |
|
| Hospital do Cancer I | Recruiting | Rio de Janeiro | Rio de Janeiro | 20230130 | Brazil |
|
| Centro de Ciencias da Saude | Recruiting | Natal | Rio Grande do Norte | 59012300 | Brazil |
|
| HCPA Hospital de Clinicas de Porto Alegre | Recruiting | Porto Alegre | Rio Grande do Sul | 900350903 | Brazil |
|
| Hospital Sao Paulo | Recruiting | São Paulo | São Paulo | 04024002 | Brazil |
|
| Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo | Recruiting | São Paulo | São Paulo | 05403000 | Brazil |
|
| D014133 | Tracheal Diseases |
| D009139 | Musculoskeletal Abnormalities |
| D000013 | Congenital Abnormalities |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |
| D003240 | Connective Tissue Diseases |
| D017437 | Skin and Connective Tissue Diseases |