Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The investigators wish to determine the lumped constant (LC), which is a correction factor necessary for converting measurements of hepatic FDG metabolism (measured by PET) to those of regular glucose in patients with cirrhosis and healthy subjects.
Working hypothesis
The LC for FDG is determined in 8 patients with liver disease and 8 healthy volunteers with and without glucose-clamp on two different days at 3-5 week intervals. The individual order of the two examinations will be randomized. The subjects fast overnight before the examination but are allowed to drink water and take usual medication.
When arriving at the PET centre, venflons are placed in a cubital vein in both arms and an ICG infusion is started in one of them. On the day with the glucose-clamp, an infusion of insulin and glucose is started in the second venflon. Next, an artflon is placed in one radial artery and a lever vein catheteter is placed via an introducer catheter in the left femoral vein under sterile conditions and local anesthetic (Lidocaine). The position of the liver vein catheter is checked with fluoroscopy.
On each experimental day, a bolus of 200 MBq FDG + 25 μCi [3H] glucose (diluted with saline up to 10 ml) is given intravenously at the start of a 60-min PET scan of the liver. Blood samples from a peripheral artery and a liver vein are collected for determination of blood concentrations of FDG and [3H]glucose at appropriate intervals.
In the experiment with glucose-clamp, an intravenous infusion of insulin (0.6 mU/kg/min) is given and blood glucose is measured every 10 min and kept constant at around 5 mM by infusing 20% glucose (infusion rate adjusted according to blood glucose).
During each study, the hepatic blood flow rate is measured by giving an intravenous infusion of indocyanine green (ICG) and collecting arterial and liver vein blood samples (Fick's principle).
Blood samples are analyzed for concentrations of FDG (gammacounter), [3H]glucose (liquid-scintillation counter), glucose (enzymatic assay) and ICG (spectrophotometric).
When the experiment is finished, all infusions are terminated and the liver vein catheter is removed and hemostasis ensured by manual compression (10 minutes) and bed rest for 30 minutes before the subject is allowed to stand. The artflon is then removed and hemostasis ensured by manual compression (10 minutes). Finally, the venflons are removed.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients with chronic liver disease | Inclusion criteria
Exclusion Criteria
|
| |
| Healthy subjects | Inclusion criteria
Exclusion Criteria
|
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Liver vein catheter | Procedure | Liver vein catheter is placed in the heptic vein via the femoral vein, using fluoroscpoy as guidance. |
|
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Recruited via 2 newspapers: Ã…rhus Onsdag and Ã…rhus Stiftstidende, and so will be based in the area these newspapers are distributed in.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael Sørensen, MD PhD | Aarhus University Hospital, PET-centre | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Aarhus University Hospital, PET-centre | Aarhus C | 8000 | Denmark |
Not provided
| ID | Term |
|---|---|
| D008103 | Liver Cirrhosis |
| ID | Term |
|---|---|
| D008107 | Liver Diseases |
| D004066 | Digestive System Diseases |
| D005355 | Fibrosis |
| D010335 | Pathologic Processes |
Not provided
Not provided
| ID | Term |
|---|---|
| D003296 | Cooking |
| ID | Term |
|---|---|
| D005511 | Food Handling |
| D019649 | Food Industry |
| D007221 | Industry |
| D013676 | Technology, Industry, and Agriculture |
Not provided
Not provided
Not provided
Not provided
Not provided
Plasma for measuring levels of ICG, insulin, c.peptide, FFA, glucagon,and 3H-glucose.
|
| D013568 |
| Pathological Conditions, Signs and Symptoms |