Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This clinical investigation of the hepatocyte matrix implant is an evaluation blinded non-randomized and monocentric pilot study of Phase I, which is conducted as a therapeutic investigation. Randomization is not possible due to ethical and practical reasons. This study has already been approved in Switzerland and has been adapted to Indonesian Law and disease.
This new treatment procedure has already been successfully used on the basis of compassionate use in Germany. The hepatocyte matrix implant is a new patented procedure consisting of bio-matrix technology. A formaldehyde-free special matrix consisting of self-dissolving polymers is applied as a carrier substance and is cultivated with human autologous cells using a special technique. Clinically the bio artificial liver replacement tissue for patients with end-stage hepatic disease has been developed as a first application. In this procedure autologous hepatocytic tissue and pancreatic tissue is removed (liver resection and pancreatic biopsy) from the patient in a first surgical procedure. The tissue is sent to a specialized Cell Culture Laboratory. The laboratory is GMP certified for this procedure. The cells are processed according to SOPs in a special perfusion procedure and prepared on several platelets of matrices (platelets of 20 mm diameter and 4mm thickness). After completion of the laboratory process the bio tissues are implanted into the mesentery of the small intestine during a second operation. The cells are growing controlled on the matrix, take on the capillaries of the patient and thus connect to the blood circulation. The implanted cells multiply by a specific factor and independently take over the metabolic function of the original liver after two to four weeks. In the following process the carrier matrix dissolves completely and implanted cells develop into liver cell tissue.
This new treatment procedure has already been successfully used on the basis of individual treatment in Germany. The hepatocyte matrix implant is a new patented procedure consisting of bio-matrix technology. A formaldehyde-free special matrix consisting of self-dissolving polymers is applied as a carrier substance and is cultivated with human autologous cells using a special technique. Clinically the bio artificial liver replacement tissue for patients with end-stage hepatic disease has been developed as a first application. In this procedure autologous hepatocytic tissue and pancreatic tissue is removed (liver resection and pancreatic biopsy) from the patient in a first surgical procedure. The tissue is sent to a specialized Cell Culture Laboratory. The laboratory is GMP certified for this procedure. The cells are processed according to SOPs in a special perfusion procedure and prepared on several platelets of matrices (platelets of 20 mm diameter and 4mm thickness). After completion of the laboratory process the bio tissues are implanted into the mesentery of the small intestine during a second operation. The cells are growing controlled on the matrix, take on the capillaries of the patient and thus connect to the blood circulation. The implanted cells multiply by a specific factor and independently take over the metabolic function of the original liver after two to four weeks. In the following process the carrier matrix dissolves completely and implanted cells develop into liver cell tissue.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| surgery | Experimental | chronic liver insufficiency, cirrhosis |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Hepatocyte Matrix Implant | Procedure | Open surgical procedure with biopsy of liver tissue and pancreatic tissue for proceeding in institutional GMP laboratory. Implantation of autologous hepatocytes and islet cells on scaffolds into the small bowel mesentery. Usually 10 to 20 implants are used. |
| Measure | Description | Time Frame |
|---|---|---|
| Evaluation of clinical and laboratory parameters of liver function | Evaluation of clinical parameters MELD, CHILD, Asictes, portal hypertension in comparison of values measured 3 and 6 months before operation Evaluation of laboratory parameters Bilirubin, ASAT, ALAT, alkaline phosphatase, cholinesterase, albumin, total protein | 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Suryadi The, Dr, MD | Contact | +62 8129204193 | sury4d1md@gmail.com | |
| Hans U Baer, Prof MD | Contact | +41 387 30 70 | hans.baer@baermed.ch |
| Name | Affiliation | Role |
|---|---|---|
| Hans U Baer, Prof, MD | Baermed, RS Gading Pluit, UNTAR | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| R.S. Gading Pluit | Recruiting | Jakarta | 14250 | Indonesia |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 33123384 | Derived | Hendrawan S, Lheman J, Nuraeni, Weber U, Baer HU. Hepatocyte and Islet Cell Cotransplantation on Poly-L-Lactide Matrix for the Treatment of Liver Cirrhosis. Int J Hepatol. 2020 Oct 13;2020:5410359. doi: 10.1155/2020/5410359. eCollection 2020. |
| Label | URL |
|---|---|
| Baermed Centre for Abdominal Surgery, Zurich, Switzerland | View source |
Not provided
Not provided
| ID | Term |
|---|---|
| D008103 | Liver Cirrhosis |
| D048550 | Hepatic Insufficiency |
| ID | Term |
|---|---|
| D008107 | Liver Diseases |
| D004066 | Digestive System Diseases |
| D005355 | Fibrosis |
| D010335 | Pathologic Processes |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| D013568 |
| Pathological Conditions, Signs and Symptoms |