The purpose of the NORDIC ICD study is to evaluate whether ICD implantation without intra-operative DF testing is non-inferior to ICD implantation with intra-operative DF testing regarding the efficacy of the first ICD shock for the treatment of true spontaneous ventricular tachyarrhythmias.
The NORDIC ICD study is justified by the need to compare the clinical outcome between patients that did receive defibrillation (DF) testing and those who did not receive DF testing during ICD implantation. The NORDIC ICD study will evaluate the impact of intra-operative DF testing on the long-term ICD first shock efficacy for true ventricular tachyarrhythmias in the observational period. Therefore, the primary analysis of this study will consider all ventricular tachyarrhythmia episodes treated by ICD shock(s) during the trial follow-up period.
Moreover, the Home MonitoringTM system of BIOTRONIK will be used in order to monitor the technical system integrity, device programming and cardiac performance continuously. It supports early information about the occurrence of VT/VF (Ventricular Tachycardia/Ventricular Fibrillation) episodes and corresponding therapies such as ICD shocks. The Home MonitoringTM capability offered by active implants has the potential to detect some of these trends early and thus to offer the possibility to intervene in time for prevention of fatal worsening of cardiac performance.
1077 patients were enrolled and randomized (1:1) in 48 centers in five European countries (Germany, Czech Republic, Denmark, Sweden and Latvia).
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Study group | Other | Patients without DF (Defibrillation) testing during ICD implantation |
|
| Control group | Other | Patients with DF testing during ICD implantation (according to standardized procedure) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| ICD implantation w/o DF test | Device | ICD implantation without Defibrillation Test |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Average efficacy of the first ICD shock for all true ventricular tachyarrhythmias | The primary endpoint is the average efficacy of the first ICD shock for all true ventricular tachyarrhythmias of a patient in the observational period. More precisely, the primary endpoint will be determined as the number of true ventricular tachyarrhythmias of a patient (that were efficiently terminated by the first shock delivered by the ICD) divided by the number of true ventricular tachyarrhythmias (treated with at least one ICD shock) of the same patient. | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Procedural and safety endpoints |
|
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Dietmar Bänsch, Prof. Dr. med. | Rostock University Hospital | Principal Investigator |
| Johan Brandt, PhD, MD | Skane University Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Universitätsklinikum Rostock | Rostock | 18057 | Germany | |||
| Arrhythmia Department Skane University Hospital |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25107947 | Background | Bansch D, Bonnemeier H, Brandt J, Bode F, Svendsen JH, Felk A, Hauser T, Wegscheider K; NORDIC ICD Trial Investigators. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial: concept and design of a randomized, controlled trial of intra-operative defibrillation testing during de novo defibrillator implantation. Europace. 2015 Jan;17(1):142-7. doi: 10.1093/europace/euu161. Epub 2014 Aug 8. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D017180 | Tachycardia, Ventricular |
| ID | Term |
|---|---|
| D013610 | Tachycardia |
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ICD implantation with DF test |
| Device |
ICD implantation with DF test according to standardized procedure |
|
| 12 months |
| Follow-Up and efficacy endpoints |
| 12 months |
| Lund |
| S-221 85 |
| Sweden |
| D000075224 |
| Cardiac Conduction System Disease |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |