The TOCCASTAR Study will assess the safety and effectiveness of a contact force sensing catheter used for ablation in patients with paroxysmal atrial fibrillation. Subjects will be randomized for treatment with either the TactiCath catheter or another ablation catheter with no contact force sensing capability. Patients will be followed for 12 months to compare the incidence of serious adverse events and freedom from recurring, symptomatic AF between the two study arms. Additional measures of treatment success including quality of life, recurrence of asymptomatic AF and procedural efficiency will also be studied.
A second phase of the study will treat up to 50 non-randomized subjects with a new version of the device under the same protocol.
It has been hypothesized that the ability to create durable lesions during radiofrequency (RF) ablation is directly correlated with a reduction in the recurrence of arrhythmia in patients with paroxysmal atrial fibrillation (PAF). Lesion depth is directly correlated with the contact force measured between the the tip of the catheter and the heart tissue. In this study, patients in whom a pulmonary vein isolation procedure has been prescribed for the treatment of PAF will be randomized for treatment with either a device incorporating contact force sensing or one without.
To be included in the study, patients 18 or older must demonstrate a history of atrial fibrillation and will have failed treatment using antiarrhythmic medications. In both study arms, ablation will be performed using an accepted treatment strategy and standard procedures. Patients will receive routine follow-up for 12 months after the procedure, with the addition of ambulatory monitoring to detect the recurrence of episodes of atrial arrhythmia. The study will compare the effectiveness of the procedure in the two arms, and will characterize any differences in safety outcomes primarily related to complications arising from the use of an ablation device and the ablation procedure.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| TactiCath | Experimental | Catheter ablation to treat paroxysmal AF using the TactiCath catheter with contact force capability |
|
| Control | Active Comparator | Catheter ablation to treat paroxysmal AF using a catheter with no contact force sensing capability |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Catheter ablation to treat paroxysmal atrial fibrillation | Device | A pulmonary vein isolation procedure will be performed using radiofrequency ablation. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Freedom From Recurrence of Symptomatic Atrial Fibrillation, Atrial Tachycardia or Atrial Flutter | Includes both acute success (successful electrical isolation of all pulmonary veins) and chronic success. Re-treatment for AF with ablation or the use of Class I or Class III antiarrhythmic drugs after a 3 month blanking period constitute a treatment failure. | 12 months |
| Incidence of Device-related Early-onset Primary Serious Adverse Events | Includes serious adverse events occurring within 7 days of the index procedure or hospital discharge, whichever is later, and diagnosed at any time during the follow-up period. | 12 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Vivek Reddy, MD | Icahn School of Medicine at Mount Sinai | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mount Sinai Medical Center | New York | New York | 10029 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 26260733 | Derived | Reddy VY, Dukkipati SR, Neuzil P, Natale A, Albenque JP, Kautzner J, Shah D, Michaud G, Wharton M, Harari D, Mahapatra S, Lambert H, Mansour M. Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation: Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study. Circulation. 2015 Sep 8;132(10):907-15. doi: 10.1161/CIRCULATIONAHA.114.014092. Epub 2015 Aug 10. |
Not provided
Not provided
300 subjects consented and were randomized, 5 subjects did not have the study device introduced. Thus 295 subjects contributed to study endpoints.
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | TactiCath | Ablation performed using the TactiCath contact force sensing catheter Catheter ablation for the treatment of paroxysmal atrial fibrillation: A pulmonary vein isolation procedure will be performed using radiofrequency ablation. |
| FG001 | Control | Ablation performed using a catheter with no contact force sensing capability Catheter ablation for the treatment of paroxysmal atrial fibrillation: A pulmonary vein isolation procedure will be performed using radiofrequency ablation. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | TactiCath | Ablation performed using the TactiCath contact force sensing catheter Catheter ablation for the treatment of paroxysmal atrial fibrillation: A pulmonary vein isolation procedure will be performed using radiofrequency ablation. |
| BG001 | Control |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Freedom From Recurrence of Symptomatic Atrial Fibrillation, Atrial Tachycardia or Atrial Flutter | Includes both acute success (successful electrical isolation of all pulmonary veins) and chronic success. Re-treatment for AF with ablation or the use of Class I or Class III antiarrhythmic drugs after a 3 month blanking period constitute a treatment failure. | Primary effectiveness was calculated using the Per Protocol (PP) population (n=280). 10 subjects who had PVI attempted were excluded from the PP population.due to insufficient data. A medical panel (DSMB) blinded to treatment, adjudicated the exclusion of subjects from the analysis (n=3 from TactiCath; n=7 from Control) | Posted | Number | participants | 12 months |
|
12 months
The Safety analysis population excludes 5 subjects who signed consent and were randomized but were not exposed to the study procedure or the study device resulting in n=295 subjects.
3 subjects were excluded from the TactiCath group resulting in n=152 subjects 2 subjects excluded from the Control group resulting in n=143 subjects
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | TactiCath | Ablation performed using the TactiCath contact force sensing catheter Catheter ablation for the treatment of paroxysmal atrial fibrillation: A pulmonary vein isolation procedure will be performed using radiofrequency ablation. |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Cardiac perforation | Cardiac disorders | Systematic Assessment |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Cardiac disorders | Cardiac disorders | Systematic Assessment |
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Lori Rusch, Ph.D. | Abbott | 651-756-2668 | lori.rusch@abbott.com |
Not provided
| ID | Term |
|---|---|
| D001281 | Atrial Fibrillation |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Ablation performed using a catheter with no contact force sensing capability Catheter ablation for the treatment of paroxysmal atrial fibrillation: A pulmonary vein isolation procedure will be performed using radiofrequency ablation. |
| BG002 | Total | Total of all reporting groups |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| OG001 | Control | Ablation performed using a catheter with no contact force sensing capability Catheter ablation for the treatment of paroxysmal atrial fibrillation: A pulmonary vein isolation procedure will be performed using radiofrequency ablation. |
|
|
| Primary | Incidence of Device-related Early-onset Primary Serious Adverse Events | Includes serious adverse events occurring within 7 days of the index procedure or hospital discharge, whichever is later, and diagnosed at any time during the follow-up period. | The Safety analysis population excludes 5 subjects who signed consent and were randomized but were not exposed to the study procedure or the study device resulting in n=295 subjects. (n=3 excluded from TactiCath; n=2 excluded from the Control group) | Posted | Number | participants | 12 months |
|
|
|
| 10 |
| 152 |
| 70 |
| 152 |
| EG001 | Control | Ablation performed using a catheter with no contact force sensing capability Catheter ablation for the treatment of paroxysmal atrial fibrillation: A pulmonary vein isolation procedure will be performed using radiofrequency ablation. | 11 | 143 | 56 | 143 |
| Atrial Perforation | Cardiac disorders | Systematic Assessment |
|
| Pulmonary edema | Respiratory, thoracic and mediastinal disorders | Systematic Assessment |
|
| Vascular Access Complication | Vascular disorders | Systematic Assessment |
|
| Hospitalization | General disorders | Systematic Assessment |
|
| Vascular disorders | Vascular disorders | Systematic Assessment |
|
| Repiratory, thoracic and mediastinal disorders | Respiratory, thoracic and mediastinal disorders | Systematic Assessment |
|
| General disorders | General disorders | Systematic Assessment |
|
| Investigations | Investigations | Systematic Assessment |
|
| Nervous systems disorders | Nervous system disorders | Systematic Assessment |
|
| Gastrointestinal disorders | Gastrointestinal disorders | Systematic Assessment |
|
| Renal and urinary disorders | Renal and urinary disorders | Systematic Assessment |
|
| Infection and infestations | Infections and infestations | Systematic Assessment |
|
| Injury, poisoning and procedural complications | Injury, poisoning and procedural complications | Systematic Assessment |
|
| Muskuloskeletal and connective disorders | Musculoskeletal and connective tissue disorders | Systematic Assessment |
|
| Metabolism and nutrition disorders | Metabolism and nutrition disorders | Systematic Assessment |
|
| Eye disorders | Eye disorders | Systematic Assessment |
|
| Immune system disorders | Immune system disorders | Systematic Assessment |
|
| Skin and subcutaneous tissue disorders | Skin and subcutaneous tissue disorders | Systematic Assessment |
|
| Blood and lymphatic system disorders | Blood and lymphatic system disorders | Systematic Assessment |
|
| Endocrine disorders | Endocrine disorders | Systematic Assessment |
|
| Psychiatric disorders | Psychiatric disorders | Systematic Assessment |
|
| Reproductive system and breast disorders | Reproductive system and breast disorders | Systematic Assessment |
|
Not provided
| D013568 |
| Pathological Conditions, Signs and Symptoms |