This study was designed to confirm that the surgeon is able to perform accurate liver surface registration including standard liver features used as landmarks during a scheduled laparoscopic liver procedure. The hypothesis is that there will be no clinically relevant difference between the error measurements obtained during the laparoscopic procedures in this study when compared with those obtained during previous open liver registration studies.
The surface of the liver will be manually swabbed with the study tracked laparoscopic probe with landmarks noted during data collection. After registration of the liver is obtained, the registration points obtained during this procedure will be evaluated by the surgeon by moving the tracked laparoscopic probe over the liver surface and evaluating the location of the tracked laparoscopic probe displayed on the guidance system three dimensional (3D) image. The surgeon will accept or reject the registration accuracy.
The Pathfinder System used during this study is used for data collection purposes only and is not used during the surgical procedure as an image guided system.
Preoperative computed tomography (CT) scans, obtained as standard of care, will be used to generate the image guided liver system 3D liver surface images used during the study.
During the laparoscopic procedure, the Pathfinder device will be inserted through the standard laparoscopic ports (5mm or 10mm) being used for the staging procedure.
A total study population will include 20 subjects that complete the laparoscopic procedure scheduled.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| The number of accurate liver surface registrations obtained in the laparoscopic environment compared to accurate liver surface registrations obtained in open procedures | Subjects are followed for the study 30days (+/- 14 days) and are considered to have completed the study following this 30 day follow-up visit. The performance of accurate physical-to-image registrations obtained during laparoscopic procedures will be compared with open liver registrations obtained from previous validation studies during open liver procedures. | 30 days |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Any subject scheduled for a laparoscopic procedure where liver surface visualization and surface swabbing is feasible with standard port placement.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| David A. Geller, M.D. | UPMC, Montefiore Hospital Liver Cancer Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| UPMC, Montefiore Hospital Liver Cancer Center | Pittsburgh | Pennsylvania | 15213 | United States |
Not provided
| Label | URL |
|---|---|
| Pathfinder Company Link | View source |
Not provided
Not provided
| ID | Term |
|---|---|
| D008113 | Liver Neoplasms |
| D009369 | Neoplasms |
| ID | Term |
|---|---|
| D004067 | Digestive System Neoplasms |
| D009371 | Neoplasms by Site |
| D004066 | Digestive System Diseases |
| D008107 | Liver Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided