To perform a pilot study of the S-FLARE imaging system, which uses low levels of safe, invisible, near-infrared light to measure tissue oxygenation during breast reconstructive surgery and to compare S-FLARE measurements to the gold standard, FDA-approved, the ViOptix optical probe.
This pilot study will enroll three patients who have chosen to proceed with deep inferior epigastric perforator (DIEP) flap breast reconstruction. This type of reconstruction uses skin and fat from the abdomen to reconstruct a new breast shape. The construct is vascularized through perforating arteries and veins that provide a blood supply to this tissue.
Current techniques to evaluate vessel selection rely on a handheld Doppler used for confirmation of blood flow and perfusion; however, this modality is limited as it only assesses a specific point within the flap.
The S-FLARE imaging system will be used to visualize vascularization in the DIEP flaps, and this study will compare measurements by the S-FLARE imaging system and the standard-of-care ViOptix point probe.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Imaging with S-FLARE imaging system | Experimental | 3 patients to be imaged by S-FLARE imaging system. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Imaging with S-FLARE imaging system | Device | Tissue oxygenation measurements during plastic surgery using the S-FLARE system. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Optimization of Ergonomics and Functioning of the S-FLARE Imaging System during Breast Reconstructive Surgery | Due to patient-to-patient anatomic variation, the vascular perfusion to the skin in DIEP flaps is unpredictable and of great concern to the surgeon planning the flap design. We propose a method of imaging tissue oxygenation within a DIEP flap base on the use of invisible near-infrared light. This pilot study is a comparison study of oxygenation measurements taken by the ViOptix optical probe as the standard of care and the S-FLARE imaging system, with the intention of optimizing the ergonomics and functionality of the S-FLARE imaging system for use during breast reconstructive surgery. | 10 minute imaging procedure |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| John V. Frangioni, MD, PhD | Beth Israel Deaconess Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Beth Israel Deaconess Medical Center | Boston | Massachusetts | 02215 | United States |
Not provided
| Label | URL |
|---|---|
| Website of the study principal investigator with detailed information about related work. | View source |
Not provided
Not provided
| ID | Term |
|---|---|
| D001943 | Breast Neoplasms |
| ID | Term |
|---|---|
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D001941 | Breast Diseases |
| D012871 | Skin Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D003952 | Diagnostic Imaging |
| ID | Term |
|---|---|
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| D017437 |
| Skin and Connective Tissue Diseases |