The objective of this study is to assess the long-term safety and quality of life improvement of the Sonitus SoundBite Hearing System.
The Sonitus Bone Conduction Device (BCD) is a bone conduction device for single-sided deafness (SSD). The Sonitus BCD consists of an Oral Appliance (OA), an external microphone component, worn behind the ear (BTE), a calibration interface cable and a PC-controlled calibration software for subject calibration. The Sonitus BCD picks up sounds from a microphone located within the ear canal of the deaf ear, capitalizing on the acoustics of the natural pinna and ear canal. The signal picked up by the microphone is then transmitted wirelessly to a removeable bone conduction oral appliance located on the upper molars. The oral appliance receives the acoustic signal from the BTE and applies an equivalent vibratory signal to the teeth that reaches the skull via bone conduction and routed transcranially to the contralateral cochlea.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| SoundBite Hearing System | Experimental | The objective of this study was to assess the long-term safety and quality of life impact of the SoundBite™ Hearing System. Safety was measured in terms of dental, audiological and medical adverse events related to device or procedure. Quality of Life was measured in terms of changes in Abbreviated Profile of Hearing Aid Benefit (APHAB) and as reported in a quality of life survey (SSD Questionnaire). The duration of the study was 6 months with measures taken at Day 1, 3 months and 6 months. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Sonitus SoundBite System | Device | Non Surgical Bone Conduction Device |
|
| Measure | Description | Time Frame |
|---|---|---|
| Long Term Safety | The safety outcomes were defined as no changes in medical, auditory, or dental status and no device or procedure related adverse events during the study period. Safety was evaluated by conducting a Comprehensive Medical evaluation at Enrollment and at study termination; Comprehensive Dental evaluation at Enrollment and at 3 and 6 months, with interim dental checks in between if necessary and Comprehensive Audiological evaluation at Enrollment and at 6 months. | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Measurement of Device Benefit With the Abbreviated Profile of Hearing Aid Benefit (APHAB) | The measure of the benefit of the device was assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) , a 24-item self-assessment inventory in which the amount of difficulty in everyday situations is reported with larger numbers indicating more difficulty. Device benefit is calculated by subtracting the score obtained after using a device from the score obtained before using the device. Software is used to score the APHAB and results are compared from the different timepoints. The APHAB is well characterized and broadly used as a quantifiable measurement. The APHAB benefit scores can range from -99 (treatment worse than no treatment) to +99 (treatment better than no treatment). |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Must not be current users of devices such as Baha, CROS or TransEar
Must not have known active medical causes of SSD
Must not have known medical problems that might be life-threatening or is a contraindication for elective dental or medical procedures
Must not have a history of seizures
Must not have known problems that may interfere with the impression procedure, such as inability to breath through nose (e.g. severe flu, allergies or cold)
Must not have allergies to polymers
Must not have known dental abnormalities
Must not have known Audiological conditions
Must not have known psychological factors that interfere with their ability to comply, comprehend, consent and cooperate
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael Murray, MD | Camino ENT | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Camino Ear Nose and Throat | San Jose | California | 95123 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 16411423 | Background | Ozer E, Adelman C, Freeman S, Sohmer H. Bone conduction hearing on the teeth of the lower jaw. J Basic Clin Physiol Pharmacol. 2002;13(2):89-96. doi: 10.1515/jbcpp.2002.13.2.89. | |
| 4712563 | Background | Dahlin GC, Allen FG, Collard EW. Bone-conduction thresholds of human teeth. J Acoust Soc Am. 1973 May;53(5):1434-7. doi: 10.1121/1.1913490. No abstract available. |
| Label | URL |
|---|---|
| product website | View source |
Not provided
Not provided
Recruitment occurred in April 2010. Subjects were informed about the potential for participation via IRB approved flyers or by indicating interest on consent forms from other studies.
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Sonitus SoundBite System | Long Term Safety was measured in terms of dental, audiological and medical adverse events related to device or procedure. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Long Term Safety | Safety was measured in terms of dental, audiological and medical adverse events related to device or procedure. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Long Term Safety | The safety outcomes were defined as no changes in medical, auditory, or dental status and no device or procedure related adverse events during the study period. Safety was evaluated by conducting a Comprehensive Medical evaluation at Enrollment and at study termination; Comprehensive Dental evaluation at Enrollment and at 3 and 6 months, with interim dental checks in between if necessary and Comprehensive Audiological evaluation at Enrollment and at 6 months. | Posted | Number | participants | 6 months |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Long Term Safety | Safety was measured in terms of dental, audiological and medical adverse events related to device or procedure. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Lily Woodby, AuD | Sonitus Medical, Inc. | 8668162076 | lily@sonitusmedical.com |
Not provided
| ID | Term |
|---|---|
| D034381 | Hearing Loss |
| D046088 | Hearing Loss, Unilateral |
| ID | Term |
|---|---|
| D006311 | Hearing Disorders |
| D004427 | Ear Diseases |
| D010038 | Otorhinolaryngologic Diseases |
| D012678 | Sensation Disorders |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| SoundBite Hearing System | Device |
|
| 3 months and 6 months |
| 11404603 | Background | Wazen JJ, Spitzer J, Ghossaini SN, Kacker A, Zschommler A. Results of the bone-anchored hearing aid in unilateral hearing loss. Laryngoscope. 2001 Jun;111(6):955-8. doi: 10.1097/00005537-200106000-00005. |
| 12958575 | Background | Wazen JJ, Spitzer JB, Ghossaini SN, Fayad JN, Niparko JK, Cox K, Brackmann DE, Soli SD. Transcranial contralateral cochlear stimulation in unilateral deafness. Otolaryngol Head Neck Surg. 2003 Sep;129(3):248-54. doi: 10.1016/S0194-5998(03)00527-8. |
| 10489868 | Background | Stenfelt SP, Hakansson BE. Sensitivity to bone-conducted sound: excitation of the mastoid vs the teeth. Scand Audiol. 1999;28(3):190-8. doi: 10.1080/010503999424761. |
| 23859058 | Background | Moore BC, Popelka GR. Preliminary comparison of bone-anchored hearing instruments and a dental device as treatments for unilateral hearing loss. Int J Audiol. 2013 Oct;52(10):678-86. doi: 10.3109/14992027.2013.809483. Epub 2013 Jul 17. |
| 21221045 | Background | Murray M, Popelka GR, Miller R. Efficacy and safety of an in-the-mouth bone conduction device for single-sided deafness. Otol Neurotol. 2011 Apr;32(3):437-43. doi: 10.1097/MAO.0b013e3182096b1d. |
| 22403981 | Background | Miller R, Hujoel P, Murray M, Popelka GR. Safety of an intra-oral hearing device utilizing a split-mouth research design. J Clin Dent. 2011;22(5):159-62. |
| 19816229 | Background | Popelka GR, Derebery J, Blevins NH, Murray M, Moore BC, Sweetow RW, Wu B, Katsis M. Preliminary evaluation of a novel bone-conduction device for single-sided deafness. Otol Neurotol. 2010 Apr;31(3):492-7. doi: 10.1097/MAO.0b013e3181be6741. |
| 21799455 | Result | Murray M, Miller R, Hujoel P, Popelka GR. Long-term safety and benefit of a new intraoral device for single-sided deafness. Otol Neurotol. 2011 Oct;32(8):1262-9. doi: 10.1097/MAO.0b013e31822a1cac. |
| Participants |
|
| Age, Continuous | Mean | Standard Deviation | years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
|
|
| Secondary | Measurement of Device Benefit With the Abbreviated Profile of Hearing Aid Benefit (APHAB) | The measure of the benefit of the device was assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) , a 24-item self-assessment inventory in which the amount of difficulty in everyday situations is reported with larger numbers indicating more difficulty. Device benefit is calculated by subtracting the score obtained after using a device from the score obtained before using the device. Software is used to score the APHAB and results are compared from the different timepoints. The APHAB is well characterized and broadly used as a quantifiable measurement. The APHAB benefit scores can range from -99 (treatment worse than no treatment) to +99 (treatment better than no treatment). | Posted | Mean | Standard Deviation | Global Benefit Score | 3 months and 6 months |
|
|
|
| 0 |
| 22 |
| 0 |
| 22 |
Not provided
| D009461 |
| Neurologic Manifestations |
| D009422 | Nervous System Diseases |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |