Patients presenting for elective surgery requiring tracheal intubation will be randomized to one of two different endotracheal tubes (ETT).
The post-operative complication of a sore throat after endotracheal intubation is unfortunately common, with estimates ranging from 15-50%. Most estimates are in the order of 35-45%.(McHardy 1999, Higgins 2002) There is evidence that many patients do not report sore throat and/or vocal changes unless directly asked because surgical pain is more prominent and many patients may be unaware that intubation completed as part of the general anesthetic. (Harding 1987)
The Parker FlexTip® endotracheal tube (ETT) is formulated with a softer plastic at the distal tip as well as a laterally curved profile to reduce trauma during ETT advancement. (Makino 2003) This ETT has been shown to be faster during fibreoptic intubation, but complication of sore throat was not examined. (Kristensen 2003)
Our previous study (Jones 2007) demonstrated that modification of anesthetic techniques could reduce the incidence of post-operative sore throat in patients undergoing naso-tracheal intubation. We will now study the Parker Flex-Tip ETT to see if its use can also reduce the incidence of sore throat in patients undergoing oro-tracheal intubation.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| FlexTip ETT | Experimental | FlexTip ETT |
|
| Control | Placebo Comparator | Standard Flexible ETT Mallinckrodt Hi-Lo cuffed tracheal tube Catalog # 86114 Mallinckrodt, ST. Louis, MO, 63134 |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| FlexTip ETT (Parker FlexTip/GlideScope FlexTip) | Device | FlexTip ETT used for endotracheal intubation |
|
| Measure | Description | Time Frame |
|---|---|---|
| Sore throat | Patients fill in a questionaire 48-72 hours after Surgery by a blinded data assessor. They are asked if they had a sore throat after their surgery. If so, they are asked to grade the sore throat as mild, moderate, or severe, when it was at its worst. Note: There is only one questionaire for both outcomes. | 48-72 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Vocal changes | Patients fill in a questionaire 48-72 hours after Surgery by a blinded data assessor. They are asked if they had vocal changes after their surgery. If so, they are asked to grade the vocal changes as mild, moderate, or severe, when the changes were at its worst. Patients are asked for one word to best characterise the vocal changes. Note: There is only one questionaire for both outcomes. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Timothy P Turkstra, MD, M. Eng | Western University, Canada | Principal Investigator |
| Philip M Jones, MD | Western University, Canada | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Western Ontario | London | Ontario | N6A5A5 | Canada |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 22057874 | Derived | Turkstra TP, Smitheram AK, Alabdulhadi O, Youssef H, Jones PM. The Flex-Tip tracheal tube does not reduce the incidence of postoperative sore throat: a randomized controlled trial. Can J Anaesth. 2011 Dec;58(12):1090-6. doi: 10.1007/s12630-011-9592-5. Epub 2011 Nov 5. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Control - standard flexible ETT (Mallinckrodt) | Device | Control - standard flexible ETT Mallinckrodt Hi-Lo cuffed tracheal tube, Catalog # 86114, Mallinckrodt, ST. Louis, MO, 63134 |
|
| 48-72 hours |