The purpose of this study is to determined effects of BreatheMAX on secretion clearance.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| breathing exercise | Experimental | BreatheMAX breathing device is Water pressure Threshold Bottle. The level of water in the cylinder determines the load for treatment. In the treatment using 20% PNIP (Peak negative inspiratory pressure) was performed with 6-10 breaths/set; 10 set/day |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| BreatheMAX breathing device | Device | secretion clearance, breathing exercise |
|
| Measure | Description | Time Frame |
|---|---|---|
| secretion wet weight (gram) | Airway mucus secretion was collected for three hours before and ten hours after treatment based on an auditory airway secretion sound and collected again at 02.00-07.00 am.The mucus secretion was collected by sterile suctioning technique via tracheostomy tube without adding any saline or sterile water. | Three hours before, ten hours after treatment and night-time (02.00-07.00 am.) |
| viscosity of secretion | The secretion were collected in three hours before and after treatment, It were measured viscosity by First The mucus was gently homogenized by tissue grinder 5 ml (Cw11-205, Cowie, UK) for six minute at 37 degree celsius Second using Micro-Oswald viscometers with a capillary diameter of 0.77 mm for viscosity measure at same temperature in each sample(before and after). | Three hours before and after treatment |
| Measure | Description | Time Frame |
|---|---|---|
| Heart rate (beat/min) | Heart rate was monitored before, during and immediate after breathing exercise with BreatheMAX (6-10 beats/set, 10 set/day and rest between ste for 1 minute) | Before, during breathing exercise with device and immediate after treatment |
| Oxygen saturation (%SpO2) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Miss Sujittra Kluayhomthong, Bachelor | Contact | 081-379-0647 | rabbit_tigger@hotmail.com | |
| Mrs. Chulee Jones, Philosophy | Contact | 664-320-2399 | Chujones46@yahoo.co.uk |
| Name | Affiliation | Role |
|---|---|---|
| Sujittra Kluayhomthong, Bachelor | Physical Therapy department, Faculty of Associated Medical Sciences, Khon Kaen university | Study Chair |
| Chulee CU Jones, Philosophy | Physical Therapy Department, Faculty of Associated Medical Sciences, Khon Kaen university, Thailand |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Pulmonary research room of physical therapy department, Faculty of associated medical sciences, Khon Kaen University | Recruiting | Muang | Changwat Khon Kaen | 40002 | Thailand |
| Type | Date | Date Unknown |
|---|---|---|
| Release | Aug 14, 2012 | |
| Reset | Sep 12, 2012 |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Aug 14, 2012 | Sep 12, 2012 |
| ID | Term |
|---|---|
| D008171 | Lung Diseases |
| ID | Term |
|---|---|
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Oxygen saturation was monitored before, during and immediate after breathing exercise with BreatheMAX (6-10 beats/set, 10 set/day and rest between set for 1 minute) |
| Before, during breathing exercise with device and immediate after treatment |
| Respiratory rate (times/min) | Respiratory rate was measured by manual for 1 minute before, rest interval between set and immediate after breathing exercise with device (during the patients reconnection mechanical ventilation) | In rest interval between set (1 minute) |
| Study Director |
| Wilaiwan Khrisanapant, Philosophy | Department of physiology, Faculty of medicine, Khon Kaen university | Study Director |