Fluid leak around the cuff is minimized when the endotracheal tube size is small relative to the size of the trachea. In the current study, the investigators assess the influence of different HVLP endotracheal tube size on fluid leakage around the cuff in a benchtop model and in anesthetized patients.
The use of a high-volume and low-pressure (HVLP) endotracheal cuff has reduced the cuff-induced tracheal damage because the cuff conforms passively to tracheal contours as it expands during inflation and the cuff inflation pressure is assumed to be equal to cuff-to-trachea pressure. However, longitudinal folds of a HVLP cuff occur on inflation within the trachea, as the diameter of the cuff is greater than that of the trachea, and these folds provide channels for an aspiration or gas leakage.
Silent aspiration of upper airway secretions has been reported in patients undergoing general anesthesia and in the intensive care unit (ICU). A previous study reported the 83% aspiration of subglottic dye detected by bronchoscopy in anesthetized patients, and other study of intubated patients with HVLP cuffs in the ICU showed 87% aspiration rate.
Intubation-related (ventilator associated pneumonia) pneumonia is a leading cause of prolongation of hospital stay, mortality and morbidity during the postoperative period and in the ICU. Therefore, it is important to achieve a better seal around the cuff without tracheal damage, which would reduce the incidence of pneumonia in intubated patients.
A previous benchtop study demonstrated that the leak around the cuff is minimized when the endotracheal tube size is small relative to the size of the trachea. In the current study, we assess the influence of different HVLP endotracheal tube size on fluid leakage around the cuff in a benchtop model and in anesthetized patients.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group ID 7.5 | Patients with a tracheal tube ID (internal diameter) 7.5 mm |
| |
| Group ID 8.0 | Patients with a tracheal tube ID 8.0 mm |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Observation of fluid leakage around tracheal tube cuffs | Other | One milliliter of Evans blue diluted in 3.5 mL of saline solution is carefully instilled on the top of the tracheal tube cuff. In the operating room, one hour and five hours after intubation, fiberoptic bronchoscopy was performed to detect the possible presence of blue dye in the trachea. If a blue spot was seen on the trachea caudal to the tube's tip on any occasion, leakage was confirmed and the experiment was finished. |
| Measure | Description | Time Frame |
|---|---|---|
| Aspiration rate | during 5 hours |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Patients,scheduled for elective cardiac surgery under general anesthesia
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Jin-Young Hwang, M.D. | Contact | 82-16-746-4750 | mistyblue15@naver.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Seoul National University Bundang Hospital | Gyeonggi-do | 463-707 | South Korea |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 6423162 | Result | Seegobin RD, van Hasselt GL. Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. Br Med J (Clin Res Ed). 1984 Mar 31;288(6422):965-8. doi: 10.1136/bmj.288.6422.965. | |
| 1115375 | Result | Pavlin EG, VanNimwegan D, Hornbein TF. Failure of a high-compliance low-pressure cuff to prevent aspiration. Anesthesiology. 1975 Feb;42(2):216-9. doi: 10.1097/00000542-197502000-00019. No abstract available. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| 11506109 | Result | Blunt MC, Young PJ, Patil A, Haddock A. Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration. Anesthesiology. 2001 Aug;95(2):377-81. doi: 10.1097/00000542-200108000-00019. |