Not provided
Not provided
Not provided
Not provided
On reviewing of new data
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Medtronic | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Empirical implantation of the left ventricular lead is the prevailing practice in cardiac resynchronization therapy device implantation. The response rate to the therapy has been uniformly 70% only despite various methods to screen patients before device implantation. This study tested the hypothesis that echocardiography to assess acute resynchronization of the left ventricle during device implantation may improve the response rate to the therapy.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Empirical | Active Comparator | Empirical implantation of the left ventricular lead during cardiac resynchronization therapy device implantation |
|
| Echocardiography-guided approach | Experimental | Echocardiography-guided implantation of the left ventricular lead during cardiac resynchronization therapy device implantation |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Empirical group | Device | Empirical implantation of the left ventricular lead during cardiac resynchronization therapy device implantation |
|
| Measure | Description | Time Frame |
|---|---|---|
| Clinical response (Improvement in functional class status by at least one NYHA Class or ≥10% increase in 6-minute hall walk distance) to CRT | 6 months after device implantation |
| Measure | Description | Time Frame |
|---|---|---|
| Echocardiographic response of ≥15% reduction in LVESV | 6 months after device implantation | |
| Echocardiographic response of absolute increase of ≥5% in LVEF | 6 months after device implantation | |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Ngai Yin Chan, MBBS | Princess Margaret Hospital, Canada | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Princess Margaret Hospital | Hong Kong | 852 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Echocardiography-guided approach | Device | Echocardiography-guided implantation of the left ventricular lead during cardiac resynchronization therapy device implantation |
|
| Biochemical response with reduction of BNP level≥15% |
| 6 months after device implantation |
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided