Intracorporeal suturing and knot tying during robotic prostatectomy and laparoscopic and robotic renal surgery have historically been considered the most technically challenging and time consuming aspects of these procedures. With improved operative technique as well as the use of innovative surgical devices, vascular control during these surgeries is often less cumbersome as compared with traditional techniques. Current standard methods of hemostasis include the use of clips, of which the most popular design is the Hemolock, a locking, nonabsorbable plastic clip, or the use of the very expensive endomechanical stapler. Unfortunately while they are associated with time savings in the operating room, there is a great deal of disposable costs associated with these various devices as well as a not insignificant device malfunction rate reported in the literature. The aim of this case-controlled study is to evaluate the Aesculap U-clip device compared to our current technique of vascular control using the Teleflex Hemolock clip device during minimally invasive genitourinary surgery.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Teleflex HemoLock clip | Placebo Comparator | Patients randomized to the Aesculap U-clip device or the HemoLock clip will undergo their respective surgery (robotic prostatectomy and laparoscopic and robotic renal surgery) as per standard protocols. During the surgical procedure, when primary vascular control is warranted the appropriate clip to which the patient has been randomized will be utilized. Immediate assessment of the vascular pedicle will subsequently occur |
|
| Aesculap U-Clip | Active Comparator | Patients randomized to the Aesculap U-clip device or the HemoLock clip will undergo their respective surgery (robotic prostatectomy and laparoscopic and robotic renal surgery) as per standard protocols. During the surgical procedure, when primary vascular control is warranted the appropriate clip to which the patient has been randomized will be utilized. Immediate assessment of the vascular pedicle will subsequently occur. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Teleflex HemoLock clip | Device | Patients randomized to the Aesculap U-clip device or the HemoLock clip will undergo their respective surgery (robotic prostatectomy and laparoscopic and robotic renal surgery) as per standard protocols. During the surgical procedure, when primary vascular control is warranted the appropriate clip to which the patient has been randomized will be utilized. Immediate assessment of the vascular pedicle will subsequently occur; if hemostasis is not adequate, additional clipping, endomechanical stapling or suture ligation will then be performed as necessary. |
| Measure | Description | Time Frame |
|---|---|---|
| significant difference in clip misfire and misapplication rates | 1month |
| Measure | Description | Time Frame |
|---|---|---|
| blood loss / need for transfusion | 1 month | |
| OR time | 1 day | |
| Need for repeat procedure |
Not provided
Inclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| S. Duke Herrell, MD | Vanderbilt University Department of Urologic Surgery | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Vanderbilt University Medical Center | Nashville | Tennessee | 37212 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17206901 | Background | Meng MV. Reported failures of the polymer self-locking (Hem-o-lok) clip: review of data from the Food and Drug Administration. J Endourol. 2006 Dec;20(12):1054-7. doi: 10.1089/end.2006.20.1054. | |
| 17919695 | Background | Hsi RS, Saint-Elie DT, Zimmerman GJ, Baldwin DD. Mechanisms of hemostatic failure during laparoscopic nephrectomy: review of Food and Drug Administration database. Urology. 2007 Nov;70(5):888-92. doi: 10.1016/j.urology.2007.06.1116. Epub 2007 Oct 24. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Aesculap U-clip | Device | Patients randomized to the Aesculap U-clip device or the HemoLock clip will undergo their respective surgery (robotic prostatectomy and laparoscopic and robotic renal surgery) as per standard protocols. During the surgical procedure, when primary vascular control is warranted the appropriate clip to which the patient has been randomized will be utilized. Immediate assessment of the vascular pedicle will subsequently occur; if hemostasis is not adequate, additional clipping, endomechanical stapling or suture ligation will then be performed as necessary. |
|
| 1 month |
| number of clips used | 1 day |
| surgeon impression of the ease of application | 1 day |
| predicted cost differential (or at least charge differential) | 1 month |