Purpose - To determine the effectiveness of custom-fit pressure garment therapy in the prevention of hypertrophic scarring in healed burns.
Background - Approximately one million people are burned each year in the United States. The most devastating outcomes following burns is the ugly, itchy, hypertrophic scar that interferes with work and all other aspects of life. Pressure garment therapy is routinely used to minimize hypertrophic scarring even though there is no scientifically valid data that this therapy is efficacious. Pressure garments are extremely unattractive, expensive and uncomfortable and their use needs to be based upon valid data.
Goals and Objectives - The investigators plan to determine the effectiveness of pressure garment therapy in the control of hypertrophic scarring in healed burns.
Methods - The I-Scan® device was designed to measure pressure at the body/environment interface and allows clinicians to deal with pressure-related problems for at-risk patients. It has been widely used in rehabilitation medicine but not with burn survivors. The investigators will use this device to measure the pressure at the garment/skin interface. 2) Furthermore, the few studies that have been attempted to determine efficacy have used between subjects designs. Since burn depth is extremely variable from patient to patient and since hypertrophic scarring is greatly influenced by age and race/origin, the between subjects design requires very large numbers of subjects. The investigators will use a within wounds design studying forearm burns and applying pressure to half of the wound and no pressure to the other half. The investigators will then compare hardness, color, thickness and clinical appearance.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Custom fabricated pressure garments | Device | Cloth garments designed to apply 17-24 mmHg pressure to the 1/2 the burn wound and <5 mmHg to the other half, to be worn 23 hours per day until wounds mature, approximately 12 months |
|
| Measure | Description | Time Frame |
|---|---|---|
| Pressure Under Compression Garment | Pressure measurements were obtained at the scar/garment interface using the I-ScanTM System (Tekscan, Inc., South Boston, MA). The device was calibrated and the pressure determined in mmHg. Pressure measurements were obtained by a therapist not involved in the care of the patient, who was trained in the use of the device. Therefore pressure ''dose'' was measured directly. Values reported are averaged over indicated visits. | Approximately 2.5, 5, 7.5, 10, and 12 months (follow-up visits 1-5) |
| Measure | Description | Time Frame |
|---|---|---|
| Durometer (Hardness) of Wound | A single Rex Durometer Hand Model 1600, Type 00, without a foot attachment (Rex Gauge Company Inc., Glenview, IL) was used to measure scar hardness throughout the study. This device measures hardness of light foams, sponge rubber gels, and animal tissue in "durometer units" (range 0=soft, 100=hard). Measurements were obtained with the person in the sitting position with the forearm supported in a horizontal position on a desk and the shoulder adducted. The area of interest was triangulated and measurements obtained at the corners were averaged; the sides of the triangle were 3-5 cm. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Loren Engrav | University of Washington | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Washington Burn Center | Seattle | Washington | 98104 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 20537469 | Background | Engrav LH, Heimbach DM, Rivara FP, Moore ML, Wang J, Carrougher GJ, Costa B, Numhom S, Calderon J, Gibran NS. 12-Year within-wound study of the effectiveness of custom pressure garment therapy. Burns. 2010 Nov;36(7):975-83. doi: 10.1016/j.burns.2010.04.014. Epub 2010 Jul 1. |
Not provided
Not provided
Not provided
During the 12-year period from 1995 to 2007, in accord with the Human Subjects Division of the University of Washington, 67 consecutive patients were enrolled. Thirteen patients exited the study prior to any data collection. Eleven of these chose to remove themselves, one was lost to follow-up and the reason was not recorded for one patient.
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Pressure Garment on Burn Wound | Pressure garment therapy was started within 2 weeks of re-epithelialization. A custom-fit pressure garment was fabricated by Medical Z Inc. (Medical Z, San Antonio, TX) and designed such that it applied pressure to only one-half of the wound, proximal or distal (according to coin toss by a consistent individual not involved in data collection for the study). The standard Lycra® 6-way stretch fabric was designed to apply 17-24 mm Hg to the normal/high compression zone and <5 mm Hg to the low compression zone. Subjects were instructed to wear the garments 23 hours per day, removing them only for bathing. |
| Title | Milestones | Reasons Not Completed | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Pressure Garment on Burn Wound | Pressure garment therapy was started within 2 weeks of re-epithelialization. A custom-fit pressure garment was fabricated by Medical Z Inc. (Medical Z, San Antonio, TX) and designed such that it applied pressure to only one-half of the wound, proximal or distal (according to coin toss by a consistent individual not involved in data collection for the study). The standard Lycra® 6-way stretch fabric was designed to apply 17-24 mm Hg to the normal/high compression zone and <5 mm Hg to the low compression zone. Subjects were instructed to wear the garments 23 hours per day, removing them only for bathing. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Pressure Under Compression Garment | Pressure measurements were obtained at the scar/garment interface using the I-ScanTM System (Tekscan, Inc., South Boston, MA). The device was calibrated and the pressure determined in mmHg. Pressure measurements were obtained by a therapist not involved in the care of the patient, who was trained in the use of the device. Therefore pressure ''dose'' was measured directly. Values reported are averaged over indicated visits. | All Participants with available and evaluable measurement. | Posted | Mean | Standard Deviation | mm Hg | Approximately 2.5, 5, 7.5, 10, and 12 months (follow-up visits 1-5) |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Pressure Garment on Burn Wound | Pressure garment therapy was started within 2 weeks of re-epithelialization. A custom-fit pressure garment was fabricated by Medical Z Inc. (Medical Z, San Antonio, TX) and designed such that it applied pressure to only one-half of the wound, proximal or distal (according to coin toss by a consistent individual not involved in data collection for the study). The standard Lycra® 6-way stretch fabric was designed to apply 17-24 mm Hg to the normal/high compression zone and <5 mm Hg to the low compression zone. Subjects were instructed to wear the garments 23 hours per day, removing them only for bathing. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Loren Engrav | University of Washington | 206-744-3209 | engrav@u.washington.edu |
Not provided
| ID | Term |
|---|---|
| D006984 | Hypertrophy |
| D002921 | Cicatrix |
| D002056 | Burns |
| ID | Term |
|---|---|
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D005355 | Fibrosis |
| D010335 | Pathologic Processes |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Approximately 2.5, 5, 7.5, 10, and 12 months (follow-up visits 1-5) |
| Color of Wound | A Chromameter Minolta CR-300 (Konica Minolta, Ramsey, NJ) measured skin color. Skin surface illuminated by pulsed xenon arc lamp. Light reflected perpendicular to surface collected for a tri-stimulus color analysis. One measurement consisted of three flashes of illumination in order to obtain a mean value. Measurement values are in the L*a*b* color space was described by The Commission Internationale de I'Eclairage (CIE)(L=brightness [100=white,0=black], a=red-green[red=60,green=-60], b=yellow-blue[yellow=60,blue=-60]) | Approximately12 months (follow-up visits 5) |
| Thickness of Wound | Scar thickness in millimeters was obtained with high-frequency ultrasonography in the Department of Radiology. Several machines and probes were used over the years each with accuracy to 0.5 mm. The area of interest was triangulated and measurements obtained at the corners were averaged; the sides of the triangle were 3-5 cm. | Approximately 12 months (follow-up visit 5) |
| Clinical Appearance of Wound | Photographs of wounds showed final cosmetic result. The two compression areas for each photograph were labeled distal (D) and proximal (P). We asked 11 experts (blinded as to the compression of the rated zones) to judge which zone (D or P) had the better cosmetic appearance or whether there was no difference. Votes were tallied according to the unblinded compression zone (i.e., high/normal and low). We report number of participants for which the rating experts all agreed or did not all agree (i.e., voted the other zone or "no difference") that the indicated zone had the better appearance. | Approximately 12 months (follow-up visit 5) |
| Compliance With Wearing Compression Garment | The patients were asked to complete a compliance form indicating how many hours the garment was worn each day. | About 12 months (follow-up visit 5) |
| years |
|
| Age, Customized | Number | participants |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| OG001 |
| Low Compression Zone |
Low compression area of custom-fit compression garment applied to 1/2 of patient's wound (randomly assigned to proximal/distal) |
|
|
| Secondary | Durometer (Hardness) of Wound | A single Rex Durometer Hand Model 1600, Type 00, without a foot attachment (Rex Gauge Company Inc., Glenview, IL) was used to measure scar hardness throughout the study. This device measures hardness of light foams, sponge rubber gels, and animal tissue in "durometer units" (range 0=soft, 100=hard). Measurements were obtained with the person in the sitting position with the forearm supported in a horizontal position on a desk and the shoulder adducted. The area of interest was triangulated and measurements obtained at the corners were averaged; the sides of the triangle were 3-5 cm. | All Participants with available and evaluable measurement. | Posted | Mean | Standard Deviation | durometer units | Approximately 2.5, 5, 7.5, 10, and 12 months (follow-up visits 1-5) |
|
|
|
| Secondary | Color of Wound | A Chromameter Minolta CR-300 (Konica Minolta, Ramsey, NJ) measured skin color. Skin surface illuminated by pulsed xenon arc lamp. Light reflected perpendicular to surface collected for a tri-stimulus color analysis. One measurement consisted of three flashes of illumination in order to obtain a mean value. Measurement values are in the L*a*b* color space was described by The Commission Internationale de I'Eclairage (CIE)(L=brightness [100=white,0=black], a=red-green[red=60,green=-60], b=yellow-blue[yellow=60,blue=-60]) | All Participants with available and evaluable measurement. | Posted | Mean | Standard Deviation | color space parameter units | Approximately12 months (follow-up visits 5) | Colorimeter observations | Participants |
|
|
|
| Secondary | Thickness of Wound | Scar thickness in millimeters was obtained with high-frequency ultrasonography in the Department of Radiology. Several machines and probes were used over the years each with accuracy to 0.5 mm. The area of interest was triangulated and measurements obtained at the corners were averaged; the sides of the triangle were 3-5 cm. | All Participants with available and evaluable measurement. | Posted | Mean | Standard Deviation | mm | Approximately 12 months (follow-up visit 5) |
|
|
|
| Secondary | Clinical Appearance of Wound | Photographs of wounds showed final cosmetic result. The two compression areas for each photograph were labeled distal (D) and proximal (P). We asked 11 experts (blinded as to the compression of the rated zones) to judge which zone (D or P) had the better cosmetic appearance or whether there was no difference. Votes were tallied according to the unblinded compression zone (i.e., high/normal and low). We report number of participants for which the rating experts all agreed or did not all agree (i.e., voted the other zone or "no difference") that the indicated zone had the better appearance. | All Participants with available and evaluable measurement. | Posted | Number | Participants | Approximately 12 months (follow-up visit 5) |
|
|
|
| Secondary | Compliance With Wearing Compression Garment | The patients were asked to complete a compliance form indicating how many hours the garment was worn each day. | All Participants with available and evaluable data. | Posted | Mean | Standard Deviation | hours per day | About 12 months (follow-up visit 5) |
|
|
|
| 0 |
| 54 |
| 0 |
| 54 |
Not provided
Not provided
| D014947 | Wounds and Injuries |
| Study Period 2 (n=44) |
|
| Study Period 3 (n=37) |
|
| Study Period 4 (n=33) |
|
| Study Period 5 (n=26) |
|
| b color parameter |
|