The purpose of this study is to investigate if there is any different follow-up results by angiography and IVUS between two different drug-eluting stents after implanted simultaneously in same individuals.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Endeavor group and Excel group | Endeavor group: measurements from the vessels implanted Endeavor stent(s). Excel group: measurements from the vessels implanted Excel stent(s). |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Segment and instent restenosis measured by coronary angiography and IVUS. | at 12 months after implantation |
| Measure | Description | Time Frame |
|---|---|---|
| Uncovered and malposition of stent. | at 12 months after implantation. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
These patients who received two kinds of drug-eluting stent (Endeavor and Excel) im simultaneously.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Liuhuaqiao Hospital | Recruiting | Guangzhou | Guangdong | 510010 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 19695548 | Background | Waseda K, Miyazawa A, Ako J, Hasegawa T, Tsujino I, Sakurai R, Yock PG, Honda Y, Kandzari DE, Leon MB, Fitzgerald PJ; ENDEAVOR IV Trial Investigators. Intravascular ultrasound results from the ENDEAVOR IV trial: randomized comparison between zotarolimus- and paclitaxel-eluting stents in patients with coronary artery disease. JACC Cardiovasc Interv. 2009 Aug;2(8):779-84. doi: 10.1016/j.jcin.2009.05.015. | |
| 18973509 |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D023903 | Coronary Restenosis |
| D003328 | Coronary Thrombosis |
| ID | Term |
|---|---|
| D023921 | Coronary Stenosis |
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| Background |
| Lee CH, Zhang J, Kailasam A, Tai BC, Ye F, Low AF, Hou X, Hay ET, Teo SG, Lim YT, Chen S, Tan HC. An intravascular ultrasound study of Cypher, Taxus, and endeavor stents on relation between neointimal proliferation and residual plaque burden. J Interv Cardiol. 2008 Dec;21(6):519-27. doi: 10.1111/j.1540-8183.2008.00397.x. Epub 2008 Oct 21. |
| 18082499 | Background | Miyazawa A, Ako J, Hongo Y, Hur SH, Tsujino I, Courtney BK, Hassan AH, Kandzari DE, Honda Y, Fitzgerald PJ; ENDEAVOR III Investigators. Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: intravascular ultrasound results from ENDEAVOR III. Am Heart J. 2008 Jan;155(1):108-13. doi: 10.1016/j.ahj.2007.08.008. Epub 2007 Sep 14. |
| D002318 |
| Cardiovascular Diseases |
| D014652 | Vascular Diseases |
| D013927 | Thrombosis |
| D016769 | Embolism and Thrombosis |