The aim of this study is to compare two methods of delivery of noninvasive mechanical ventilation (NIV).
Since patient compliance and mechanical characteristics of the delivery devices are two fundamental variables in the success of NIV during acute respiratory failure, our hypothesis is that an improved patient-ventilator interface may improve the efficacy of therapy.
Noninvasive ventilation (NIV) is the delivery of ventilatory support without the need for an invasive artificial airway. The use of noninvasive positive-pressure ventilation (NPPV) in acute respiratory failure has been steadily increasing for intensive care unit (ICU) patients. Noninvasive ventilation can often eliminate the need for intubation or tracheostomy and preserve normal swallowing, speech, and cough mechanisms. Discomfort of the device is one of the reason for the failure of NIV (30-40% of the cases).
The Novastar oro-nasal mask (Dräger Medical, Lubeck, Germany) is a flexible, transparent mask shell with a fine silicone gel cushion which adapts to the wearer's face. The pliable ring embedded inside the flexible clear shell allows the mask to be bent and adjusted to fit the patient's face (customized fit), while minimizing leakages. The mask has magnetic, self aligning clips for capture and secure fastening of the mask headgear. The magnetic clips are self-aligning.
The transparent flexible helmet for NIV (Rüsch 4-Vent, Teleflex Medical Europe, Athlone, Ireland) is fixed with two straps passing through each armpit. The braces are protected by hydrocolloid strips to prevent axillary decubitus. It is important to chose the right size of the helmet to avoid air leakages in the neck region. Two filters in the in- and expiratory way are necessary to reduce noise.
Different devices may lead to varying degrees of discomfort and, thus, improve compliance. Better tolerability of NIV may improve its efficacy. Therefore, we planned this randomized controlled trial to investigate whether different modalities of NIV delivery may affect therapeutical efficacy.
No randomized trials have compared helmets to the NOVASTAR full-face masks. This randomized, controlled study aims to assess whether the new full face mask improves gas exchange in patients admitted to ICU because of acute postoperative respiratory failure.
METHODS
Patients meeting criteria for NIV cycles will be enrolled in this trial. Informed written consent requirements were waived by the Internal Review Board since enrollment criteria meet common clinical guidelines and the two devices are both widely available (and approved for this indication).
Enrollment criteria are:
Patients will be excluded if:
Upon enrolment, patients will be randomized to receive NIV via one of the two available interfaces. In group H (for "helmet"), the continuous positive pressure is obtained by a high influx of fresh gases (air + oxygen) flowing through a high-compliance reservoir, with a positive end-expiratory pressure valve limiting outflow. In the M ("oral-nasal mask") group the same flow scheme is obtained using a T-tube attached to the mask. Patients' heads will be elevated to about 45° in both groups.
In both groups continuous positive airway pressure (CPAP) will be instituted at 5 cmH2O. Pressure will be increased by increments of 2-3 cmH2O until a maximum of 10 cmH2O in order to reach a peripheral blood oxygen saturation (SpO2) ≥ 90% with the lowest FiO2 possible.
Noninvasive ventilation will be ideally maintained for up to 24 h. Patients will be asked to wear the helmet/mask as long as possible. During ventilation-free periods, which will be maintained as short as possible, patients will receive 50% oxygen supplementation. The criteria for success of therapy and discontinuation of NIV will be a reversal of all criteria listed above for enrollment.
Criteria for NIV failure and subsequent intubation and mechanical ventilation will be:
MAIN ENDPOINT AND SAMPLE SIZE
Arterial blood gas analyses will be performed upon enrollment, after 1 h, and after 24 h from enrollment. The null hypothesis of the study is that there will be no difference in the mean PaO2/FiO2 values between the two groups at 24 h. We will consider as clinically and statistically significant a difference of ≥50±60 mmHg between the groups.
A total of 50 patients will be enrolled. Sample size calculations are based on the assumption of a 5% risk of type I error and a 20% risk of type II error, while accounting for a 10-15% attrition rate.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Helmet | Active Comparator | Patients in this group will receive continuous positive airway pressure delivered through a helmet connected to a high-flow reservoir system. |
|
| Mask | Experimental | Patients in this group will receive continuous positive-airway pressure delivered through a novel full-face mask connected to a high-flow system. Expiratory pressure will be maintained using an expiratory valve connected to a T-tube. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Helmet | Device | Continuous positive airway pressure for up to 24 h. Initial pressure will be 5 cmH2O, and will be increased by 2-3 cmH2O up to 10 cmH2O, in order to maintain SpO2 ≥90%. |
| Measure | Description | Time Frame |
|---|---|---|
| Differences in PaO2/FiO2 ratio with respect to baseline (before NIV) values. | 24 h |
| Measure | Description | Time Frame |
|---|---|---|
| PaO2/FiO2 improvement at 1 h after beginning of ventilation. | 1 h after enrollment | |
| Arterial carbon dioxide partial pressure (PaCO2) | At 1 and 24 h post-enrollment | |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Guido Fanelli, MD | Dept. of Anesthesiology and Critical Care Medicine, University of Parma, Italy | Study Chair |
| Maria Barbagallo, MD | UO II Anestesia, Rianimazione e Terapia Antalgica, Azienda Ospedaliero-Universitaria di Parma | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University and Hospital of Parma (Azienda Ospedaliero-Universitaria di Parma) | Parma | PR | 43126 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 8173743 | Background | Appendini L, Patessio A, Zanaboni S, Carone M, Gukov B, Donner CF, Rossi A. Physiologic effects of positive end-expiratory pressure and mask pressure support during exacerbations of chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 1994 May;149(5):1069-76. doi: 10.1164/ajrccm.149.5.8173743. | |
| 9872200 | Background |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Full-face mask | Device | Continuous positive airway pressure for up to 24 h. Initial pressure will be 5 cmH2O, and will be increased by 2-3 cmH2O up to 10 cmH2O, in order to maintain SpO2 ≥90%. |
|
|
| Arterial blood pressure and incidence of hypotension (systolic blood pressure <90 mmHg or mean arterial blood pressure <60 mmHg) |
| Up to 24 h post-enrollment |
| Need for intubation | Up to 24 h post-enrollment |
| Intensive care unit stay | Up to 30 days |
| In-hospital mortality | Up to 30 days |
| Device-related complications: pressure sores, skin necrosis, air leak, eye inflammation, gastric distension. | Up to 24 h post-enrollment |
| Patient's rating of comfort with the device. Numerical rating scale ranging from 1 (unbearable) to 5 (very good.) | At 1 and 24 h post-enrollment |
| Success rate of NIV as delivered with either helmet or full-face mask. Success is defined as ≥50 mmHg improvement of PaO2/FiO2 ratio. | 24 h from initiation of therapy |
| Celikel T, Sungur M, Ceyhan B, Karakurt S. Comparison of noninvasive positive pressure ventilation with standard medical therapy in hypercapnic acute respiratory failure. Chest. 1998 Dec;114(6):1636-42. doi: 10.1378/chest.114.6.1636. |
| 16174945 | Background | Chadda K, Clair B, Orlikowski D, Macadoux G, Raphael JC, Lofaso F. Pressure support versus assisted controlled noninvasive ventilation in neuromuscular disease. Neurocrit Care. 2004;1(4):429-34. doi: 10.1385/NCC:1:4:429. |
| 16438899 | Background | Collaborative Research Group of Noninvasive Mechanical Ventilation for Chronic Obstructive Pulmonary Disease. Early use of non-invasive positive pressure ventilation for acute exacerbations of chronic obstructive pulmonary disease: a multicentre randomized controlled trial. Chin Med J (Engl). 2005 Dec 20;118(24):2034-40. |
| 15599160 | Background | Keenan SP, Sinuff T, Cook DJ, Hill NS. Does noninvasive positive pressure ventilation improve outcome in acute hypoxemic respiratory failure? A systematic review. Crit Care Med. 2004 Dec;32(12):2516-23. doi: 10.1097/01.ccm.0000148011.51681.e2. |
| 7767523 | Background | Kramer N, Meyer TJ, Meharg J, Cece RD, Hill NS. Randomized, prospective trial of noninvasive positive pressure ventilation in acute respiratory failure. Am J Respir Crit Care Med. 1995 Jun;151(6):1799-806. doi: 10.1164/ajrccm.151.6.7767523. |
| 16380593 | Background | Masip J, Roque M, Sanchez B, Fernandez R, Subirana M, Exposito JA. Noninvasive ventilation in acute cardiogenic pulmonary edema: systematic review and meta-analysis. JAMA. 2005 Dec 28;294(24):3124-30. doi: 10.1001/jama.294.24.3124. |
| 8549183 | Background | Meduri GU, Turner RE, Abou-Shala N, Wunderink R, Tolley E. Noninvasive positive pressure ventilation via face mask. First-line intervention in patients with acute hypercapnic and hypoxemic respiratory failure. Chest. 1996 Jan;109(1):179-93. doi: 10.1378/chest.109.1.179. |
| 7924369 | Background | Meduri GU, Fox RC, Abou-Shala N, Leeper KV, Wunderink RG. Noninvasive mechanical ventilation via face mask in patients with acute respiratory failure who refused endotracheal intubation. Crit Care Med. 1994 Oct;22(10):1584-90. |
| ID | Term |
|---|---|
| D012131 | Respiratory Insufficiency |
| D012128 | Respiratory Distress Syndrome |
| D029424 | Pulmonary Disease, Chronic Obstructive |
| D011654 | Pulmonary Edema |
| D053120 | Respiratory Aspiration |
| ID | Term |
|---|---|
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
| D008171 | Lung Diseases |
| D008173 | Lung Diseases, Obstructive |
| D002908 | Chronic Disease |
| D020969 | Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D006260 | Head Protective Devices |
| D045422 | Continuous Positive Airway Pressure |
| D063087 | Noninvasive Ventilation |
| ID | Term |
|---|---|
| D000067393 | Personal Protective Equipment |
| D011482 | Protective Devices |
| D004864 | Equipment and Supplies |
| D008420 | Manufactured Materials |
| D013676 | Technology, Industry, and Agriculture |
| D011175 | Positive-Pressure Respiration |
| D012121 | Respiration, Artificial |
| D058109 | Airway Management |
| D013812 | Therapeutics |
| D012138 | Respiratory Therapy |
Not provided
Not provided